MT02646 Home Control Metering Plug

This describes the Z-Wave device MT02646, manufactured by Devolo with the thing type UID of devolo_mt02646_00_000.

Home Control Metering Plug

Channels

The following table summarises the channels available for the MT02646 Home Control Metering Plug.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Reset the total power consumption meter_reset meter_reset Energy Switch
Alarm alarm_general alarm_general Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the MT02646 Home Control Metering Plug. Detailed information on each parameter can be found below.

Parameter Description
1: Watt Meter Report Period multiples of 5s
2: KWH Meter Report Period number of 10 minute intervals
3: Threshold of current for Load Caution 1300*0.01A = 13A
4: Threshold of KWh for Load Caution load caution threshold
5: Restore switch state mode Restore switch state mode.
6: Mode of switch off function Mode of switch off function.
7: LED indication mode Restore switch state mode.
8: Auto off timer Auto off timer. 0 will disable the auto off function.
9: RF off command mode RF off command mode
1: Reports Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT.

1: Watt Meter Report Period

multiples of 5s

Overview

Enable automatic interval in seconds reporting with an interval of 5s * the value. Set to 0 will disable the autoreporting function.

Property Value      
Configuration ID config_1_2      
Data Type INTEGER      
Range 0 to 32767   Default Value 720
Options Disable (0)      

2: KWH Meter Report Period

number of 10 minute intervals

Overview

Enable automatic interval in minutes reporting with an interval of 10min * the value. Set to 0 will disable the autoreporting function.

Property Value      
Configuration ID config_2_2      
Data Type INTEGER      
Range 0 to 32767   Default Value 6
Options Disable (0)      

3: Threshold of current for Load Caution

1300*0.01A = 13A

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 10 to 1300
Default Value 1300

4: Threshold of KWh for Load Caution

load caution threshold

Overview

Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh.. Set to 0 will disable kWh load caution reporting.

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 1 to 10000
Default Value 10000

5: Restore switch state mode

Restore switch state mode.

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options Upon the return of AC power, the switch will remain Off. (0)      
  resume previous state (1)      
  Upon the return of AC power, the switch will turn On. (2)      

6: Mode of switch off function

Mode of switch off function.

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 1
Options SWITCH OFF commands received are ignored. (0)      
  SWITCH OFF commands received are honored. (1)      

7: LED indication mode

Restore switch state mode.

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 1
Options The LED follows the state of the switch. (1)      
  LED off with load ON (2)      
  Flash mode (3)      

8: Auto off timer

Auto off timer. 0 will disable the auto off function.

Property Value      
Configuration ID config_8_2      
Data Type INTEGER      
Range 0 to 255   Default Value 0
Options Disable (0)      

9: RF off command mode

RF off command mode

Property Value      
Configuration ID config_9_1      
Data Type INTEGER   Default Value 0
Options When SWITCH ALL OFF is received, the MT02646 turns Off. (0)      
  Ignore ALL OFF (1)      
  If ALL OFF is received, turn ON if it is OFF (2)      
  When SWITCH ALL OFF is received, the MT02646 turns On. (3)      

1: Reports

Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.