MT2653 Keyfob

This describes the Z-Wave device MT2653, manufactured by Devolo with the thing type UID of devolo_mt2653_00_000.

Keyfob

Channels

The following table summarises the channels available for the MT2653 Keyfob.

Channel Channel Id Channel Type UID Category Item Type
Scene Number scene_number scene_number   Number
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the MT2653 Keyfob. Detailed information on each parameter can be found below.

Parameter Description
1: Button 1 and 3 pair mode In separate mode button 1 works with group 1, button 3 with groups 3. Click is On, Hold is…
2: Button 2 and 4 pair mode In separate mode button 1 works with group 2, button 4 with groups 3. Click is On, Hold is…
11: Action on group 1 This parameter defines the command to be sent to devices of control group A when the relat…
12: Action on group 2 This parameter defines the command to be sent to devices of control group B when the relat…
13: Action on group 3 This parameter defines the command to be sent to devices of control group C when the relat…
14: Action on group 4 This parameter defines the command to be sent to devices of control group D when the relat…
21: Send the following Switch All commands  
22: Invert buttons  
25: Block Wake up Blocks wake up even when Wake Up Interval is set
30: Send unsolicited Battery Report on Wake Up  
1: ZWave Plus Lifeline ZWave Plus Lifeline
2: Controlled by button 1 or single clicks of buttons 1 and 3  
3: Controlled by button 3 or double clicks of buttons 1 and 3  
4: Controlled by button 2 or single clicks of buttons 2 and 4  
5: Controlled by button 4 or double clicks of buttons 2 and 4  

1: Button 1 and 3 pair mode

In separate mode button 1 works with group 1, button 3 with groups 3. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Separately (0)      
  In pair without double clicks (1)      
  In pair with double clicks (2)      

2: Button 2 and 4 pair mode

In separate mode button 1 works with group 2, button 4 with groups 3. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 2/4 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options Separately (0)      
  In pair without double clicks (1)      
  In pair with double clicks (2)      

11: Action on group 1

This parameter defines the command to be sent to devices of control group A when the related button is pressed.

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control devices in proximity (6)      
  Control door lock (7)      
  Central scene to gateway (8)      

12: Action on group 2

This parameter defines the command to be sent to devices of control group B when the related button is pressed.

Property Value      
Configuration ID config_12_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control devices in proximity (6)      
  Control door lock (7)      
  Central scene to gateway (8)      

13: Action on group 3

This parameter defines the command to be sent to devices of control group C when the related button is pressed.

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control devices in proximity (6)      
  Control door lock (7)      
  Central scene to gateway (8)      

14: Action on group 4

This parameter defines the command to be sent to devices of control group D when the related button is pressed.

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control devices in proximity (6)      
  Control door lock (7)      
  Central scene to gateway (8)      

21: Send the following Switch All commands

Property Value      
Configuration ID config_21_1      
Data Type INTEGER   Default Value 1
Options Switch off only (1)      
  Switch on only (2)      
  Switch all on and off (255)      

22: Invert buttons

Property Value      
Configuration ID config_22_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  Yes (1)      

25: Block Wake up

Blocks wake up even when Wake Up Interval is set

Property Value      
Configuration ID config_25_1      
Data Type INTEGER   Default Value 0
Options Wake up is BLOCKED (0)      
  Wake up is POSSIBLE according to Intervall (1)      

30: Send unsolicited Battery Report on Wake Up

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  To same node as wake up notification (1)      
  Broadcast to neighbours (2)      

1: ZWave Plus Lifeline

ZWave Plus Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Controlled by button 1 or single clicks of buttons 1 and 3

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Controlled by button 3 or double clicks of buttons 1 and 3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Controlled by button 2 or single clicks of buttons 2 and 4

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Controlled by button 4 or double clicks of buttons 2 and 4

Property Value
Configuration ID group_5
Data Type TEXT
Range to