MT2792 Home Control Metering Plug

This describes the Z-Wave device MT2792, manufactured by Devolo with the thing type UID of devolo_mt2792_00_000.

Home Control Metering Plug

Channels

The following table summarises the channels available for the MT2792 Home Control Metering Plug.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number   Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kVAh) meter_kvah meter_kvah Energy Number
Electric meter (pulses) meter_pulse meter_pulse Energy Number
Reset Meter meter_reset meter_reset Energy Switch
Alarm alarm_general alarm_general Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the MT2792 Home Control Metering Plug. Detailed information on each parameter can be found below.

Parameter Description
1: Watt counter reporting period multiples of 5s
2: KWh counter reporting period number of 10 minute intervals
3: Definition of warning of current load (A) 1300*0.01A = 13A
4: Definition of warning of load fuse protection (kWh) load caution threshold
5: Mode for restoring status Restore switch state mode.
6: Switch OFF mode Mode of switch off function.
7: LED display mode Display device status
8: Auto off timer Auto off timer. 0 will disable the auto off function.
9: Device from command status RF off command mode
1: Reports Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT.

1: Watt counter reporting period

multiples of 5s

Overview

Enable automatic interval in seconds reporting with an interval of 5s * the value. Set to 0 will disable the autoreporting function.

Property Value      
Configuration ID config_1_2      
Data Type INTEGER      
Range 0 to 32767   Default Value 720
Options Disable (0)      

2: KWh counter reporting period

number of 10 minute intervals

Overview

Enable automatic interval in minutes reporting with an interval of 10min * the value. Set to 0 will disable the autoreporting function.

Property Value      
Configuration ID config_2_2      
Data Type INTEGER      
Range 0 to 32767   Default Value 6
Options Disable (0)      

3: Definition of warning of current load (A)

1300*0.01A = 13A

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 10 to 1300
Default Value 1300

4: Definition of warning of load fuse protection (kWh)

load caution threshold

Overview

Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh.. Set to 0 will disable kWh load caution reporting.

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 1 to 10000
Default Value 10000

5: Mode for restoring status

Restore switch state mode.

Overview

Status of the plug if it is disconnected and reconnected from the mains power supply.

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options Upon the return of AC power, the switch will remain Off. (0)      
  resume previous state (1)      
  Upon the return of AC power, the switch will turn On. (2)      

6: Switch OFF mode

Mode of switch off function.

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 1
Options SWITCH OFF commands received are ignored. (0)      
  SWITCH OFF commands received are honored. (1)      

7: LED display mode

Display device status

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 1
Options The LED follows the state of the switch. (1)      
  LED off with load ON (2)      
  Flash mode (3)      

8: Auto off timer

Auto off timer. 0 will disable the auto off function.

Property Value      
Configuration ID config_8_2      
Data Type INTEGER      
Range 0 to 32767   Default Value 0
Options Disable (0)      

9: Device from command status

RF off command mode

Property Value      
Configuration ID config_9_1      
Data Type INTEGER   Default Value 0
Options When SWITCH ALL OFF is received, the MT2792 turns Off. (0)      
  Ignore ALL OFF (1)      
  If ALL OFF is received, turn ON if it is OFF (2)      
  When SWITCH ALL OFF is received, the MT2792 turns On. (3)      

1: Reports

Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.