SES FS-ZW Plug Actuator

This describes the Z-Wave device SES FS-ZW, manufactured by Diehl AKO with the thing type UID of diehl_sesfszw_00_000.

Plug Actuator

Inclusion Information

The inclusion process is controlled by the central unit – refer to the documentation for the central unit.

  1. Plug the plug actuator into a fixed mains outlet with grounding contacts (CEE 7/4).

  2. Start “Inclusion” mode on the chosen central unit.

  3. Press the button on the plug actuator 3 times within a period of around 2 seconds.

The Status LED lights up white.

During the next 5 seconds, the wireless connection is established and the inclusion process for linking the plug actuator to the central unit is performed.

Exclusion Information

The exclusion process is controlled by the central unit – refer to the documentation for the central unit.

  1. Make sure that no device is plugged into the plug actuator.

  2. Start “Exclusion” mode on the chosen central unit.

  3. Press the button on the plug actuator 3 times within a period of around 2 seconds.

The Status LED lights up white.

The exclusion process for disconnecting the plug actuator from the central unit runs for the next 5 seconds. The Status LED flashes white 3x once the exclusion process has been successfully completed.

Channels

The following table summarises the channels available for the SES FS-ZW Plug Actuator.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Alarm (system) alarm_system alarm_system   Switch
Alarm (heat) alarm_heat alarm_heat   Switch
Alarm (power) alarm_power alarm_power Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the SES FS-ZW Plug Actuator. Detailed information on each parameter can be found below.

Parameter Description
1: Default switch state Behaviour after mains failure
2: Energy minimum report time Minimum time between two (non-requested) energy values
3: Energy maximum report time Maximum time between two energy values, independently of changes in the value
4: Power minimum report time Minimum time between two (non-requested) power values
5: Power maximum report time Maximum time between two power values, independently of changes in the value
6: Energy delta value Minimum change required for a new energy value to be transmitted.
7: Power delta value Minimum change required for a new power value to be transmitted.
8: Safety shutdown configuration Behaviour in the event of a safety shutdown
10: Night mode Set Night mode of the Status LED
11: Info LED colour Set color of the Info LED
9: Reset of overcurrent shutdown Activation despite 3x safety shutdown
1: reportd  

1: Default switch state

Behaviour after mains failure

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 2
Options Plug actuator OFF (0)      
  Plug actuator ON (1)      
  Last status is restored (2)      

2: Energy minimum report time

Minimum time between two (non-requested) energy values

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 32767
Default Value 10

3: Energy maximum report time

Maximum time between two energy values, independently of changes in the value

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 0 to 32767
Default Value 120

4: Power minimum report time

Minimum time between two (non-requested) power values

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 0 to 32767
Default Value 10

5: Power maximum report time

Maximum time between two power values, independently of changes in the value

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 0 to 32767
Default Value 120

6: Energy delta value

Minimum change required for a new energy value to be transmitted.

Overview

The transmission must take place in the time window between parameter 2 and 3.

Property Value
Configuration ID config_6_2
Data Type INTEGER
Range 0 to 32767
Default Value 10

7: Power delta value

Minimum change required for a new power value to be transmitted.

Overview

The transmission must take place in the time window between parameter 4 and 5

Property Value
Configuration ID config_7_2
Data Type INTEGER
Range 0 to 32767
Default Value 150

8: Safety shutdown configuration

Behaviour in the event of a safety shutdown

Overview

The plug actuator remains OFF after 3x safety shutdowns.

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 0
Options Plug actuator remains OFF (0)      
  Automatic restart (1)      

10: Night mode

Set Night mode of the Status LED

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 0
Options Night mode OFF (0)      
  Night mode ON (1)      

11: Info LED colour

Set color of the Info LED

Property Value      
Configuration ID config_11_2      
Data Type INTEGER   Default Value 0
Options Info LED OFF (0)      
  Info LED green (1)      
  Info LED yellow (2)      
  Info LED red (3)      

9: Reset of overcurrent shutdown

Activation despite 3x safety shutdown

Overview

 Activation despite 3x safety shutdown (parameter 8 = 1)

 A reset request (“Set” command) is normally executed very quickly, as a result of which a query (“Get” command) for this parameter usually returns the response “0” (no reset) for this parameter. In some cases, this can be interpreted incorrectly. Consequently, this parameter should be treated only as “write only”. 

Property Value      
Configuration ID config_9_1_wo      
Data Type INTEGER   Default Value 0
Options No reset (0)      
  Reset (1)      

1: reportd

Property Value
Configuration ID group_1
Data Type TEXT
Range to