The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

DCH-Z510 Siren

This describes the Z-Wave device DCH-Z510, manufactured by D-Link with the thing type UID of dlink_dchz510_00_000.

The device is in the category of Siren, defining Siren used by Alarm systems.

The DCH-Z510 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

Inclusion Information

  1. Have Z-Wave Controller enter inclusion mode.
  2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode.
  3. After add successful, the LED will light ON 1 second

Exclusion Information

  1. Have Z-Wave Controller enter exclusion mode.
  2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.
  3. Node ID has been excluded.

Channels

The following table summarises the channels available for the DCH-Z510 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Binary Sensor sensor_binary Door Switch
Start sound notification_send   Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Start sound

Notification

Event

Sound

event1 Smokealarm (0x01)

0x01 ~ 0xFF

fire alert

event2 Accesscontrol (0x06)

Window/Door open (0x16)

door chime

event7 Accesscontrol (0x06)

Activate alarm system (0x03)

2x beep

event8 Accesscontrol (0x06)

Deactivate alarm system (0x04)

1x beep

event3 Homesecurity (0x07)

0x01 ~ 0xFF

emergency

sound event4 Emergency (0x0A)

Contact police (0x01)

policecar

sound

event5 Emergency (0x0A)

Contact fire department (0x02)

fire engine sound

event6 Emergency (0x0A)

Contact ambulance (0x03)

ambulance

sound

event9 Emergency (0x0A) Notification (0xFE)

silent alarm (no sound, flashing LED)

Sends a notification.

The notification_send channel supports the Number item.

Device Configuration

The following table provides a summary of the 3 configuration parameters available in the DCH-Z510. Detailed information on each parameter can be found in the sections below.

Param Name Description
7 Customer Function  
29 Disable Alarm  
31 Alarm Duration Play alarm sound duration, 1 tick is 30 seconds. 0 means never auto stop.

Parameter 7: Customer Function

The following option values may be configured -:

Value Description
0 Using Notification Report
16 Using Sensor Binary Report

The manufacturer defined default value is 0 (Using Notification Report).

This parameter has the configuration ID config_7_1_00000010 and is of type INTEGER.

Parameter 29: Disable Alarm

The following option values may be configured -:

Value Description
0 Enable Alarm
1 Disable Alarm

The manufacturer defined default value is 0 (Enable Alarm).

This parameter has the configuration ID config_29_1 and is of type INTEGER.

Parameter 31: Alarm Duration

Play alarm sound duration, 1 tick is 30 seconds. 0 means never auto stop.

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_31_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DCH-Z510 supports 1 association group.

Group 1: Report Messages

The group 1 is for receiving the report message, like tamper event. This is the device’s Lifeline group. The group supports 8 nodes maximum. This group supports 8 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SENSOR_BINARY_V0  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V0  
COMMAND_CLASS_ALARM_V3  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2  
COMMAND_CLASS_VERSION_V1  
COMMAND_CLASS_SECURITY_V0  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.