DCH-Z110 Door & Window Sensor

This describes the Z-Wave device DCH-Z110, manufactured by D-Link with the thing type UID of dlink_dchz110_00_000.

Door & Window Sensor

Channels

The following table summarises the channels available for the DCH-Z110 Door & Window Sensor.

Channel Channel Id Channel Type UID Category Item Type
Door / Window Status sensor_door sensor_door Door Contact
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Alarm alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the DCH-Z110 Door & Window Sensor. Detailed information on each parameter can be found below.

Parameter Description
2: Basic Set Level Setting the BASIC command value to turn on the light.
3: PIR Sensitivity Set the sensitivity for the PIR (Passive Infrared Sensor).
4: Light Threshold Set the illumination threshold to turn on the light.
5: Operation Mode Parameter to set the Operation Mode. Bit 0: Reserved. Bit 1: 1 means enable test mode; 0 m…
6: Multi-Sensor Function Switch Parameter to set the sensor functions.
7: Customer Function Parameter to set the Customer Function.
7: Disable send of BASIC OFF after door closed  
7: Notification Type  
7: Disable Multi CC in auto report  
7: Disable to report battery state when the device triggered  
8: PIR Re-Detect Interval Time In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds p…
9: Turn Off Light Time After turn on the light, setting the delay time to turn off the light when the PIR motion …
10: Auto Report Battery Time The interval time for auto reporting the battery level.
11: Auto Report Door/Window State Time The interval time for auto reporting the door/window state.
12: Auto Report Illumination Time The Interval time for auto reporting the illumination state.
13: Auto Report Temperature Time The interval time for auto reporting the temperature state.
20: Auto Report Tick Interval The interval time for each auto report tick. Setting this configuration will effect config…
21: Temperature Differential Report The temperature differential to report. The unit is Fahrenheit. When enabled, the device w…
22: Illumination Differential Report The illumination differential to report. The unit is percentage. When enabled, the device …
1: Reports  
2: Light Control  

2: Basic Set Level

Setting the BASIC command value to turn on the light.

Overview
  • 0: Turn off the light.
  • 1 - 100: For dimmers 1 to 100 means the light level.
  • 255: Turns on the light. (Default) 
Property Value      
Configuration ID config_2_1      
Data Type INTEGER      
Range 0 to 100   Default Value 255
Options Off (0)      
  On (255)      

3: PIR Sensitivity

Set the sensitivity for the PIR (Passive Infrared Sensor).

Overview
  • 0 = Disable the PIR motion detection.
  • 1 - 99 = 1 means the lowest sensitivity, 99 means the highest sensitivity

High sensitivity means de

Property Value      
Configuration ID config_3_1      
Data Type INTEGER      
Range 0 to 99   Default Value 70
Options Disable (0)      

4: Light Threshold

Set the illumination threshold to turn on the light.

Overview

When the event triggers and the environment illumination is lower than the threshold, the device will turn on the light.

  • 0 = Turn off illumination detected function and never turn
Property Value      
Configuration ID config_4_1      
Data Type INTEGER      
Range 0 to 100   Default Value 100
Options Disable (0)      

5: Operation Mode

Parameter to set the Operation Mode. Bit 0: Reserved. Bit 1: 1 means enable test mode; 0 means normal mode. Notice: Ignored if DIP Switch is not set to Customer Mode. Bit 2: Disable the door/window function. 1

Property Value      
Configuration ID config_5_1      
Data Type INTEGER      
Range 0 to 127   Default Value 0
Options Preset: Celsius and LED on = Bits: 00001010 = 10 (10)      

6: Multi-Sensor Function Switch

Parameter to set the sensor functions.

  • Bit 0: Disable magnetic integrate illumination to turn on the lighting nodes in the association group 2. 1: Disable, 0: Enable
  • Bit 1: Disable PIR integrate Illumination to turn on the
Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 0 to 127
Default Value 4

7: Customer Function

Parameter to set the Customer Function.

Overview

l

Property Value      
Configuration ID config_7_1      
Data Type INTEGER      
Range 0 to 127   Default Value 4
Options Preset: PIR Super Sensitivity and Binary Report = Bits: 00010100 = 20 (20)      

7: Disable send of BASIC OFF after door closed

Property Value      
Configuration ID config_7_1_00000008      
Data Type INTEGER   Default Value 1
Options Enable (0)      
  Disable (1)      

7: Notification Type

Property Value      
Configuration ID config_7_1_00000010      
Data Type INTEGER   Default Value 0
Options Notification Report (0)      
  Sensor Binary Report (1)      

7: Disable Multi CC in auto report

Property Value      
Configuration ID config_7_1_00000020      
Data Type INTEGER   Default Value 0
Options Enable (0)      
  Disable (1)      

7: Disable to report battery state when the device triggered

Property Value      
Configuration ID config_7_1_00000040      
Data Type INTEGER   Default Value 0
Options Enable (0)      
  Disable (1)      

8: PIR Re-Detect Interval Time

In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default is 3 (24 seconds).

  • 1 - 127 = Number of ticks. 8 seconds per tick, default value is 3 (24 seconds).
Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 1 to 127
Default Value 3

9: Turn Off Light Time

After turn on the light, setting the delay time to turn off the light when the PIR motion is not detected.

  • 0 = Never send turn off light command.
  • 1 - 127 = Number of ticks. 8 seconds per tick, default value is 4 (32 seconds
Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 127
Default Value 4

10: Auto Report Battery Time

The interval time for auto reporting the battery level.

  • 0 = Turn off auto report battery.
  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.
Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 127
Default Value 12

11: Auto Report Door/Window State Time

The interval time for auto reporting the door/window state.

  • 0 = Turn off auto report door/window state.
  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.
Property Value
Configuration ID config_11_1
Data Type INTEGER
Range 0 to 127
Default Value 12

12: Auto Report Illumination Time

The Interval time for auto reporting the illumination state.
0 = Turn off auto report illumination. 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 1 to 127
Default Value 12

13: Auto Report Temperature Time

The interval time for auto reporting the temperature state.

  • 0 = Turn off auto report temperature.
  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.
Property Value
Configuration ID config_13_1
Data Type INTEGER
Range 1 to 127
Default Value 12

20: Auto Report Tick Interval

The interval time for each auto report tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. 0 = Turn off all auto report functions. 1-255 = Interval time for each tick. Default is 30. Unit is in minutes

Property Value
Configuration ID config_20_1
Data Type INTEGER
Range 0 to 255
Default Value 30

21: Temperature Differential Report

The temperature differential to report. The unit is Fahrenheit. When enabled, the device will measure the temperature every minute and when the temperature is over 140 degree Fahrenheit, it will continuesly report. Enabling this functionality will cause s

Property Value
Configuration ID config_21_1
Data Type INTEGER
Range 0 to 127
Default Value 1

22: Illumination Differential Report

The illumination differential to report. The unit is percentage. When enabled, the device will measure every minute. Enabling this functionality will cause some issue. Please check the “Illumination Report” section of the Multisensor manual.

Property Value
Configuration ID config_22_1
Data Type INTEGER
Range 0 to 99
Default Value 1

1: Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Light Control

Property Value
Configuration ID group_2
Data Type TEXT
Range to