DCH-Z120 Battery Motion Sensor

This describes the Z-Wave device DCH-Z120, manufactured by D-Link with the thing type UID of dlink_dchz120_00_000.

Battery Motion Sensor

Channels

The following table summarises the channels available for the DCH-Z120 Battery Motion Sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Alarm alarm_motion alarm_motion Door Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the DCH-Z120 Battery Motion Sensor. Detailed information on each parameter can be found below.

Parameter Description
2: Basic Set Level Setting the BASIC command value to turn on the light.
3: PIR Sensitivity Set the sensitivity for the PIR (Passive Infrared Sensor).
4: Light Threshold Set the illumination threshold to turn on the light.
5: Operation Mode Parameter to set the Operation Mode.
6: Multi-Sensor Function Switch Parameter to set the sensor functions.
7: Customer Function Parameter to set the Customer Function.
7: Bit1: Enable sending motion OFF report. 0:Disable, 1:Enable
7: Bit2: Enable PIR super sensitivity mode. 0:Disable, 1:Enable
7: Bit4: Notification Type 0: Using Notification Report. 1: Using Sensor Binary Report.
7: Bit5: Disable Multi CC in auto report. 1:Disable, 0:Enable
7: Bit6: Disable to report battery state when device triggered 1:Disable, 0 Enable
8: PIR Re-Detect Interval Time Set re-detect time after PIR motion triggered
9: Turn Off Light Time Set delay time to turn off light after motion triggered.
10: Auto Report Battery Time Interval time for auto reporting the battery level
12: Auto Report Illumination Time Interval time for auto reporting the illumination.
13: Auto Report Temperature Time Interval time for auto reporting the temperature.
20: Auto Report Tick Interval Interval time for auto reporting each tick.
21: Temperature Differential Report The temperature differential to report.
22: Illumination Differential Report The illumination differential to report.
1: Reports  
2: Light Control  

2: Basic Set Level

Setting the BASIC command value to turn on the light.

Overview
  • 0: Turn off the light.
  • 1 - 100: For dimmers 1 to 100 means the light level.
  • 255: Turns on the light. (Default) 
Property Value      
Configuration ID config_2_1      
Data Type INTEGER      
Range 1 to 100   Default Value 255
Options Off (0)      
  On (255)      

3: PIR Sensitivity

Set the sensitivity for the PIR (Passive Infrared Sensor).

Overview
  • 0 = Disable the PIR motion detection.
  • 1 - 99 = 1 means the lowest sensitivity, 99 means the highest sensitivity

High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency.  

Property Value      
Configuration ID config_3_1      
Data Type INTEGER      
Range 1 to 99   Default Value 80
Options Disable (0)      

4: Light Threshold

Set the illumination threshold to turn on the light.

Overview

When the event triggers and the environment illumination is lower than the threshold, the device will turn on the light.

  • 0 means turn off illumination detected function. And never turn on the light.
  • 1 means darkest. 99 means brightest.
  • 100 means turn off illumination detected function. And always turn on the light.  

Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value.  

Property Value      
Configuration ID config_4_1      
Data Type INTEGER      
Range 1 to 99   Default Value 99
Options Disable, Light OFF (0)      
  Disable, Light ON (100)      

5: Operation Mode

Parameter to set the Operation Mode.

Overview

Bit0: Reserve

Bit1: 1 means test mode, 0 means normal mode

Bit2: Disable the door/window function. (1:Disable, 0:Enable)

Bit3: Setting the temperature scale. 0: Fahrenheit, 1: Celsius

Bit4: Disable the illumination report after event triggered. (1:Disable, 0:Enable)

Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable)

Bit6: Reserve

Bit7: Disable the back key release into test mode. (1:Disable, 0:Enable)

Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 0 to 255
Default Value 0

6: Multi-Sensor Function Switch

Parameter to set the sensor functions.

Overview

Bit0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable)

Bit1: Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable)

Bit2: Disable magnetic integrate PIR to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable) (Default is Disable)

Bit3: When Bit2 is 0 (Enable), are the device and the lighting in the same room? 0: In the same room(Default), 1: In the different room. Notice: If this bit is 1, it is recommended also set the Bit1 to 1, cause the PIR triggered, doesn’t mean the people in that room.

Bit4: Disable delay 5 seconds to turn off the light, when door/window closed. (1:Disable, 0:Enable)

Bit5: Disable auto turn off the light, after door/window opened to turn on the light. (1:Disable, 0:Enable) Notice: If bit2 is zero, this setting isuseless. Notice: If the configuration No.9 is zero, this setting is useless.

Bit6: Reserve.

Bit7: Reserve.

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 0 to 63
Default Value 4

7: Customer Function

Parameter to set the Customer Function.

Overview

Bit0: Reserve.

Bit1: Enable sending motion OFF report. (0:Disable, 1:Enable) Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00

Bit2: Enable PIR super sensitivity mode. (0:Disable, 1:Enable)

Bit3: Disable send out BASIC OFF after door closed. (1:Disable, 0:Enable) NOT USED WITH DCH-Z120

Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.

Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable)

Bit6: Disable to report battery state when the device triggered. (1:Disable,0:Enable)

Bit7: Reserve.

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 0 to 127
Default Value 4

7: Bit1: Enable sending motion OFF report.

0:Disable, 1:Enable

Overview

Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00  

Property Value      
Configuration ID config_7_1_00000002      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

7: Bit2: Enable PIR super sensitivity mode.

0:Disable, 1:Enable

Property Value      
Configuration ID config_7_1_00000004      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

7: Bit4: Notification Type

0: Using Notification Report. 1: Using Sensor Binary Report.

Property Value      
Configuration ID config_7_1_00000010      
Data Type INTEGER   Default Value 0
Options Notification Report (0)      
  Sensor Binary Report (1)      

7: Bit5: Disable Multi CC in auto report.

1:Disable, 0:Enable

Property Value      
Configuration ID config_7_1_00000020      
Data Type INTEGER   Default Value 0
Options Enable (0)      
  Disable (1)      

7: Bit6: Disable to report battery state when device triggered

1:Disable, 0 Enable

Property Value      
Configuration ID config_7_1_00000040      
Data Type INTEGER   Default Value 0
Options Enable (0)      
  Disable (1)      

8: PIR Re-Detect Interval Time

Set re-detect time after PIR motion triggered

Overview

8 seconds per tick, default tick is 3 (24 seconds).
Setting the suitable value to prevent received the trigger signal too frequently. Also can save the battery energy.
Notice: If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR not start detecting.  

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 1 to 127
Default Value 3

9: Turn Off Light Time

Set delay time to turn off light after motion triggered.

Overview

After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected.
8 seconds per tick, default tick is 4 (32 seconds).
0 means never send turn off light command.  

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 127
Default Value 4

10: Auto Report Battery Time

Interval time for auto reporting the battery level

Overview

The interval time for auto report the battery level.
0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20.  

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 127
Default Value 12

12: Auto Report Illumination Time

Interval time for auto reporting the illumination.

Overview

The interval time for auto report the illumination.
0 means turn off auto report illumination.
The default value is 12. The tick time can setting by the configuration No.20.  

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 0 to 127
Default Value 12

13: Auto Report Temperature Time

Interval time for auto reporting the temperature.

Overview

The interval time for auto report the temperature.
0 means turn off auto report temperature.
The default value is 12. The tick time can setting by the configuration No.20.  

Property Value
Configuration ID config_13_1
Data Type INTEGER
Range 0 to 127
Default Value 12

20: Auto Report Tick Interval

Interval time for auto reporting each tick.

Overview

The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13.
Caution: Setting to 0 means turn off all auto report function  

Property Value
Configuration ID config_20_1
Data Type INTEGER
Range 0 to 255
Default Value 30

21: Temperature Differential Report

The temperature differential to report.

Overview

The temperature differential to report.
0 means turn off this function.
The unit is Fahrenheit.
Enable this function the device will detect every minutes.
And when the temperature is over 140 degree Fahrenheit, it will continue report.
Enable this functionality will cause some issue please see the detail in the “Temperature Report” section.  

Property Value
Configuration ID config_21_1
Data Type INTEGER
Range 0 to 127
Default Value 1

22: Illumination Differential Report

The illumination differential to report.

Overview

The illumination differential to report.
0 means turn off this function.
The unit is percentage.
Enable this function the device will detect every minutes.
Enable this functionality will cause
some issue please see the detail in the
“Illumination Report” section  

Property Value
Configuration ID config_22_1
Data Type INTEGER
Range 0 to 99
Default Value 0

1: Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Light Control

Property Value
Configuration ID group_2
Data Type TEXT
Range to