DMS01 Dome Wireless Siren

This describes the Z-Wave device DMS01, manufactured by Elexa Consumer Products Inc. with the thing type UID of elexa_dms01_00_000.

DMS01 product image

The DMS01 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the DMS01 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Alarm alarm_general Door Switch
Battery Level battery-level Battery Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the DMS01. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Primary Notification Volume Level  
2 Primary Notification Length  
3 Secondary Notification Length  
4 Secondary Notification Volume Level  
5 Primary Notification Sound  
6 Secondary Notification Sound  
7 Toggle secondary chime Toggles between primary and secondary chime for binary switch

Parameter 1: Primary Notification Volume Level

The following option values may be configured -:

Value Description
1 Low Volume
2 Medium Volume
3 High Volume

The manufacturer defined default value is 2 (Medium Volume).

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: Primary Notification Length

The following option values may be configured -:

Value Description
1 30 Seconds
2 1 Minute
3 5 Minutes
255 Plays Until Battery Is Depleted

The manufacturer defined default value is 2 (1 Minute).

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Secondary Notification Length

The following option values may be configured -:

Value Description
0 Does Not Stop
1 1 Minute
5 5 Minutes
255 Chime Will Not Play

The manufacturer defined default value is 1 (1 Minute).

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Secondary Notification Volume Level

The following option values may be configured -:

Value Description
1 Low Volume
2 Medium Volume
3 High Volume

The manufacturer defined default value is 2 (Medium Volume).

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Primary Notification Sound

The siren offers ten different sounds to use as the Siren (primary) notification. This parameter sets the Siren (primary) notification sound. The following option values may be configured -:

Value Description
1 Ding dong
2 Fur Elise
3 Westminster Chime
4 Dingdongdingdongdingdong
5 William Tell Overture
6 Classical
7 Weeooeeooeeooeeoo
8 Err-err-err-err-err
9 Beepbeepbeepbeep (Default)
10 beeeep-beeeep-beeeep

The manufacturer defined default value is 9 (Beepbeepbeepbeep (Default)).

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: Secondary Notification Sound

The following option values may be configured -:

Value Description
1 Ding dong
2 Fur Elise
3 Westminster Chime
4 Dingdongdingdongdingdong
5 William Tell Overture
6 Classical
7 Weeooeeooeeooeeoo
8 Err-err-err-err-err
9 Beepbeepbeepbeep (Default)
10 beeeep-beeeep-beeeep

The manufacturer defined default value is 9 (Beepbeepbeepbeep (Default)).

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: Toggle secondary chime

Toggles between primary and secondary chime for binary switch

The following option values may be configured -:

Value Description
1 Primary notification will play
2 Secondary notification will play

The manufacturer defined default value is 1 (Primary notification will play).

This parameter has the configuration ID config_7_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_ALARM_V6  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  
COMMAND_CLASS_INDICATOR_V1  