DMMZ1 Dome Battery powered Z-Wave Plus enabled mousetrap

This describes the Z-Wave device DMMZ1, manufactured by Elexa Consumer Products Inc. with the thing type UID of elexa_dmmz1_00_000.

Dome Battery powered Z-Wave Plus enabled mousetrap

Channels

The following table summarises the channels available for the DMMZ1 Dome Battery powered Z-Wave Plus enabled mousetrap.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Alarm alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the DMMZ1 Dome Battery powered Z-Wave Plus enabled mousetrap. Detailed information on each parameter can be found below.

Parameter Description
1: BASIC_SET Level Sets the value sent by the BASIC_SET command to Association Group 2
2: Set Firing Mode This parameter sets the “firing mode” of the Mouser.
3: High Voltage Duration Time How long the Mouser will fire continuously before it starts to burst-fire
4: Enable/Disable LED Alarm Enables or disables the indicator LED alarm when the trap is tripped
5: LED Alarm Duration Sets the amount of time the LED Indicator blinks after the trap is tripped
1: Group 1  
2: Group 2  
3: Group 3  
4: Group 4  

1: BASIC_SET Level

Sets the value sent by the BASIC_SET command to Association Group 2

Overview

This parameter sets the value sent by the BASIC_SET command to Association Group 2 (for more information, see “Assocation Groups”.)

00 (0/Turn Off Device)

01 ~ 63 (0-99)

FF (255/Turn On Device)

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 255
Default Value 255

2: Set Firing Mode

This parameter sets the “firing mode” of the Mouser.

Overview

This parameter sets “firing mode” of the Mouser. Two firing modes are available: in the first (Continuous Fire,) electricity is passed continuously for the entire duration, and in the second (Burst Fire,) electricity is passed continuously only for the first minute and it is pulsed at approximately 400 beats per minute for the remainder of the time.

01 (Continuous Fire)

02 (Burst Fire)

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 2
Options Continuous Fire (1)      
  Burst Fire (2)      

3: High Voltage Duration Time

How long the Mouser will fire continuously before it starts to burst-fire

Overview

This parameter defines how long the Mouser will fire continuously before it starts to burst-fire (see parameter 2.)

00 64 ~ 01 68 (100~360 in Seconds)

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 64 to 168
Default Value 64

4: Enable/Disable LED Alarm

Enables or disables the indicator LED alarm when the trap is tripped

Overview

This parameter enables or disables the indicator LED alarm when the trap is tripped.

00 (LED Alarm Disabled)

01 (LED Alarm Enabled)

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 1
Options LED Alarm Disabled (0)      
  LED Alarm Enabled (1)      

5: LED Alarm Duration

Sets the amount of time the LED Indicator blinks after the trap is tripped

Overview

This parameter sets the amount of time the LED Indicator blinks after the trap is tripped.

00 (LED Alarm Blinks Until Trap is Cleared)

01~FF (1~255 in Hours)

Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 0 to 255
Default Value 0

1: Group 1

Overview

Group 1 is the “Lifeline” group, which can hold five members, typically including the main Z-Wave controller. The Door/Window Sensor sends this group a Notification Report and a Binary Sensor Report when it is tripped, reset, armed, and disarmed. It also sends this group a Battery Report in response to Battery Get commands.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Overview

The Mouser sends a Basic Set command to Association Group 2 (or the Control Group) to directly trigger devices (like a light, chime, etc.) when it is tripped. After the trap is reset, a BASIC_SET(00) command is sent to reset the device (e.g. turn off the light.) The value of the Basic Set command (e.g. brightness of the lamp) is configured using configuration parameter 1.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 3

Overview

Group 3 supports up to 5 members and the Mouser sends it a NOTIFICATION_REPORT when tripped, reset, armed, and disarmed.

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Group 4

Overview

Group 4 supports up to 5 members and the Mouser sends it a SENSOR_BINARY_REPORT when tripped, reset, armed, and disarmed.

Property Value
Configuration ID group_4
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.