DMOF1 Dome On/Off zwave wall plug for controlling small appliances and lights.

This describes the Z-Wave device DMOF1, manufactured by Elexa Consumer Products Inc. with the thing type UID of elexa_dmof1_00_000.

Dome On/Off zwave wall plug for controlling small appliances and lights.

Channels

The following table summarises the channels available for the DMOF1 Dome On/Off zwave wall plug for controlling small appliances and lights..

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Alarm (power) alarm_power alarm_power Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the DMOF1 Dome On/Off zwave wall plug for controlling small appliances and lights.. Detailed information on each parameter can be found below.

Parameter Description
1: Disable Meter Functionality Enable/Disable the meter report.
2: METER_REPORT The time between meter reports.
3: Set "Overload" Current level Maximum current the plug will pass
4: Set "Alert" Current Level Current level warning threshold
5: Enable/Disable Indicator LED This parameter enables or disables the indicator LED.
6: Current change METER_REPORT level Report of relative change in current flow
7: Remember On/Off status Remember status from last plug in.
8: 01 Timer once plugged in before it turn off the device.
9: Set Timer Time Interval Time before auto shut off if on.
10: Enable/Disable BUTTON Turn off the button
1: Lifeline  
2: Group 2  
3: Group 3  

1: Disable Meter Functionality

Enable/Disable the meter report.

Overview

This parameter enables/disables the METER_REPORT function, which sends periodic reports to Group1 members with information on line voltage, current load, and power & energy consumption. Also see Param 2 & 6.

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Disable Meter Functionality (0)      
  Enable Meter Functionality (1)      

2: METER_REPORT

The time between meter reports.

Overview

This parameter sets the amount of time between each successive METER_REPORT signal sent to Group 1 (also see Param 1 & 6.)

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 1 to 65535
Default Value 300

3: Set "Overload" Current level

Maximum current the plug will pass

Overview

Sets the maximum current the plug will pass before it cuts off power and sends a NOTIFICATION_EVENT_POWER_ MANAGEMENT_OVER_LOAD_DETECTED signal to Group 1 and a BASIC_SET(FF) to Group 2. The LED will then blink red once per second until the current returns to normal. To clear the NOTIFICATION and start monitoring again, the BUTTON must be pushed once (only after the current is back to normal.) NOTE: this value must be higher than Param 4

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 1 to 16
Default Value 13

4: Set "Alert" Current Level

Current level warning threshold

Overview

Sets the current level at which the On/Off Plug-In Switch will flash its LED yellow, until the current returns to below this level. It will NOT cut off current to the device; this functions as a visible warning to the user. NOTE: this value must be lower than Param 3

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 1 to 16
Default Value 12

5: Enable/Disable Indicator LED

This parameter enables or disables the indicator LED.

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options Disable LED (0)      
  Enable LED (1)      

6: Current change METER_REPORT level

Report of relative change in current flow

Overview

In addition to sending a METER_REPORT to Group 1 in the time interval set by Param 2, the On/Off Plug-In Switch also sends a METER_REPORT when it detects a relative change in current flow. This parameter sets this minimum current change amount, in percent, at which point the On/Off Plug-In Switch will send a METER_REPORT to Group 1. Also see Param 1 & 2.

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 1 to 64
Default Value 5

7: Remember On/Off status

Remember status from last plug in.

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 1
Options Don't Remember (0)      
  Remember (1)      

8: 01

Timer once plugged in before it turn off the device.

Overview

If this parameter is enabled, whenever the On/Off Plug-In Switch is turned on, it will automatically turn off after a set amount of time (set in Param 9.)

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 0 to 1
Default Value 0

9: Set Timer Time Interval

Time before auto shut off if on.

Overview

Sets the time interval before the On/Off Plug-In Switch automatically shuts off. See Param 8.

Property Value
Configuration ID config_9_4
Data Type INTEGER
Range 1 to 65535
Default Value 96

10: Enable/Disable BUTTON

Turn off the button

Overview

If this parameter is enabled, the user can turn the device on or off using the BUTTON.

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 1
Options Disable Button (0)      
  Enable Button (1)      

1: Lifeline

Overview

Group 1 is the “Lifeline” group, which can hold five devices. The On/Off Plug-In Switch sends this group a Notification Report and Binary Switch Report whenever it is turned on or off. It also sends a Meter Report incrementally based on time (see Param 2,) or when a relative change in power usage is detected (see Param 6.) Finally, the On/Off Plug-In Switch sends this group a Device Reset Locally notification to remove itself from the Z-Wave network. 

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Overview

The On/Off Plug-In Switch sends a BASIC_SET(FF) command to Association Group 2 to directly trigger devices (like a siren, chime, etc.) when the current passes above the level set in Parameter 3. When the current drops below the level again, a BASIC_SET(00) command is sent to reset the device (e.g. turn off the siren.) This Group can hold five devices.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 3

Overview

The On/Off Plug-In Switch sends Notification Reports to Group 3, and it can hold five devices.

Property Value
Configuration ID group_3
Data Type TEXT
Range to