DMWD1 Dome door & window sensor

This describes the Z-Wave device DMWD1, manufactured by Elexa Consumer Products Inc. with the thing type UID of elexa_dmwd1_00_000.

Dome door & window sensor

Channels

The following table summarises the channels available for the DMWD1 Dome door & window sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Alarm (access) alarm_access alarm_access Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the DMWD1 Dome door & window sensor. Detailed information on each parameter can be found below.

Parameter Description
1: BASIC_SET Off Delay The delay time from when the Door/Window Sensor sends the BASIC_SET command.
2: BASIC_SET Level Sets the value sent by the BASIC_SET command to Association Group 2
1: Group 1  
2: Group 2  
3: Group 3  
4: Group 4  

1: BASIC_SET Off Delay

The delay time from when the Door/Window Sensor sends the BASIC_SET command.

Overview

The delay time from when the Door/Window Sensor sends the BASIC_SET command to Association Group 2 and when the BASIC_SET(0) is sent. It accepts a value up to 65,535, in seconds.

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 1 to 65535
Default Value 30

2: BASIC_SET Level

Sets the value sent by the BASIC_SET command to Association Group 2

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 255
Options 0/Turn Off Device (0)      
  Turn On Device (255)      

1: Group 1

Overview

Group 1 is the “Lifeline” group, which can hold five members, typically including the main Z-Wave controller. The Door/Window Sensor sends this group a Notification Report and a Binary Sensor Report when it is opened or closed. It also sends this group a Battery Report in response to Battery Get commands.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Overview

The Door/Window Sensor sends a Basic Set command to Association Group 2 (or the Control Group) to directly trigger devices (like a light, chime, etc.) in response to events. Then, after a preset delay, a BASIC_ SET(00) command is sent to reset the device (e.g. turn off the light.) The value of the Basic Set command (e.g. brightness of the lamp,) and the delay time before the BASIC_SET(00) is sent is configured using configuration parameters 1 and 2 respectively. 

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 3

Overview

Group 3 supports up to 5 members and the Door/Window Sensor sends it a NOTIFICATION_REPORT when the door either opens or closes.

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Group 4

Overview

Group 4 supports up to 5 members and the Door/Window Sensor sends it a SENSOR_BINARY_REPORT when the door either opens or closes

Property Value
Configuration ID group_4
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.