ZW15SM Binary Switch + Meter

This describes the Z-Wave device ZW15SM, manufactured by Wenzhou MTLC Electric Appliances Co.,Ltd. with the thing type UID of enerwave_zw15sm_00_000.

The ZW15SM supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

Inclusion Information

The process of “Inclusion/ Exclusion” is to Add or Remove the device from the Hub. All Z-Wave devices must be “Included” on the Controller (Hub) before it can be controlled from a smart device. The Hub should be brought physically closer to the device just for the “Inclusion” process (recommended within 10ft). When finished, the Hub and device can be moved back to final installation location.

  1. Go to the “Add Device” page.
  2. Select “Include Device”.
  3. When prompted, press the “ON” or “OFF” Button on the switch

Exclusion Information

  1. From the Control Panel, go the the device Exclusion page.
  2. Select “Exclude Device”.
  3. When prompted, press the “ON” or “OFF” Button on the switch.

Channels

The following table summarises the channels available for the ZW15SM -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Electric meter (watts) meter_watts Energy Number
Electric meter (kWh) meter_kwh Energy Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the ZW15SM. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 LED Toggle Synchronization of load power and LED indicator
2 Button Toggle Configure button toggle
8 Instant Energy Autosend Interval (METER_REPORT) Instant Energy Autosend Interval (METER_REPORT)
9 Instant Energy Autosend Interval (SENSOR_MULTILEVEL_REPORT) Instant Energy Autosend Interval (SENSOR_MULTILEVEL_REPORT)
10 Accumulated Energy Autosend Interval report (METER_REPORT) Accumulated Energy Autosend Interval report (METER_REPORT)
11 Power change notification Enable automatic notifications whenever there is a wattage change
12 Power change notification threshold Minimum change in wattage report
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: LED Toggle

Synchronization of load power and LED indicator

The following option values may be configured -:

Value Description
0 Power on, LED off
1 Power on, LED on

The manufacturer defined default value is 0 (Power on, LED off).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Button Toggle

Configure button toggle

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 8: Instant Energy Autosend Interval (METER_REPORT)

Instant Energy Autosend Interval (METER_REPORT) Send METER_REPORT at this interval

0 means to not send Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Instant Energy Autosend Interval (SENSOR_MULTILEVEL_REPORT)

Instant Energy Autosend Interval (SENSOR_MULTILEVEL_REPORT) Send SENSOR_MULTILEVEL_REPORT at this interval

0 means to not send Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Accumulated Energy Autosend Interval report (METER_REPORT)

Accumulated Energy Autosend Interval report (METER_REPORT) Send accumulated METER_REPORT at this interval

0 means to not send Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Power change notification

Enable automatic notifications whenever there is a wattage change Enable automatic notifications to associated device whenever there is a wattage change

0: No report

1: Send METER_REPORT

2: Send SENSOR_MULTILEVEL_REPORT

3: Send both METER_REPORT and SENSOR_MULTILEVEL_REPORT Values in the range 0 to 3 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Power change notification threshold

Minimum change in wattage report When the power changes by this many watts, send an automatic power level notification

0: 0.0W
….
255: 25.5W Values in the range 0 to 255 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZW15SM supports 4 association groups.

Group 1: Lifeline

Send device reset locally notification This group supports 1 nodes.

Group 2: StatusReport

Send basic report This group supports 5 nodes.

Group 3: PowerReport

Send meter power report This group supports 5 nodes.

Group 4: AssignGroupSet

Send Basic set command This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_METER_V3  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  