The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

ZW20R 20A Tamper Resistant Duplex Receptacle

This describes the Z-Wave device ZW20R, manufactured by Wenzhou MTLC Electric Appliances Co.,Ltd. with the thing type UID of enerwave_zw20r_00_000.

ZW20R product image

The ZW20R supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

Inclusion Information

When the controller is in inclusion mode and the blue LED blinks on the
ZW20R, press the program button of ZW20R, and then the controller will
verify the inclusion

Exclusion Information

When the controller is in exclusion mode, press the
program button of ZW20R, and then the controller will remove it from the
current Z-Wave network, and the LED will blink on the receptacle.

Wakeup Information

mains device

Channels

The following table summarises the channels available for the ZW20R -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Switch 1 switch_binary1 Switch Switch
Switch 2 switch_binary2 Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the ZW20R. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Toggle LED mode Set to 1 for LED to be in sync with switch.
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Toggle LED mode

Set to 1 for LED to be in sync with switch.

The following option values may be configured -:

Value Description
0 0: LED is on when switch is off
1 1: LED is on when switch is on

The manufacturer defined default value is 0 (0: LED is on when switch is off).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_VERSION_V1| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC|

Endpoint 2

Command Class Comment
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.