ZW15SM Binary Switch + Meter

This describes the Z-Wave device ZW15SM, manufactured by Wenzhou MTLC Electric Appliances Co.,Ltd. with the thing type UID of enerwave_zw15sm_00_000.

Binary Switch + Meter

Inclusion Information

The process of “Inclusion/ Exclusion” is to Add or Remove the device from the Hub. All Z-Wave devices must be “Included” on the Controller (Hub) before it can be controlled from a smart device. The Hub should be brought physically closer to the device just for the “Inclusion” process (recommended within 10ft). When finished, the Hub and device can be moved back to final installation location. 

  1. Go to the “Add Device” page.
  2. Select “Include Device”.
  3. When prompted, press the “ON” or “OFF” Button on the switch

Exclusion Information

  1. From the Control Panel, go the the device Exclusion page.
  2. Select “Exclude Device”.
  3. When prompted, press the “ON” or “OFF” Button on the switch.

Channels

The following table summarises the channels available for the ZW15SM Binary Switch + Meter.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW15SM Binary Switch + Meter. Detailed information on each parameter can be found below.

Parameter Description
1: LED Toggle Synchronization of load power and LED indicator
2: Button Toggle Configure button toggle
8: Instant Energy Autosend Interval (METER_REPORT) Instant Energy Autosend Interval (METER_REPORT)
9: Instant Energy Autosend Interval (SENSOR_MULTILEVEL_REPORT) Instant Energy Autosend Interval (SENSOR_MULTILEVEL_REPORT)
10: Accumulated Energy Autosend Interval report (METER_REPORT) Accumulated Energy Autosend Interval report (METER_REPORT)
11: Power change notification Enable automatic notifications whenever there is a wattage change
12: Power change notification threshold Minimum change in wattage report
1: Lifeline Send device reset locally notification
2: StatusReport Send basic report
3: PowerReport Send meter power report
4: AssignGroupSet Send Basic set command

1: LED Toggle

Synchronization of load power and LED indicator

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options Power on, LED off (0)      
  Power on, LED on (1)      

2: Button Toggle

Configure button toggle

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 1
Default Value 0

8: Instant Energy Autosend Interval (METER_REPORT)

Instant Energy Autosend Interval (METER_REPORT)

Overview

Send METER_REPORT at this interval

0 means to not send

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 0 to 255
Default Value 0

9: Instant Energy Autosend Interval (SENSOR_MULTILEVEL_REPORT)

Instant Energy Autosend Interval (SENSOR_MULTILEVEL_REPORT)

Overview

Send SENSOR_MULTILEVEL_REPORT at this interval

0 means to not send

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 255
Default Value 0

10: Accumulated Energy Autosend Interval report (METER_REPORT)

Accumulated Energy Autosend Interval report (METER_REPORT)

Overview

Send accumulated METER_REPORT at this interval

0 means to not send

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 255
Default Value 0

11: Power change notification

Enable automatic notifications whenever there is a wattage change

Overview

Enable automatic notifications to associated device whenever there is a wattage change

0: No report

1: Send METER_REPORT

2: Send SENSOR_MULTILEVEL_REPORT

3: Send both METER_REPORT and SENSOR_MULTILEVEL_REPORT

Property Value
Configuration ID config_11_1
Data Type INTEGER
Range 0 to 3
Default Value 1

12: Power change notification threshold

Minimum change in wattage report

Overview

When the power changes by this many watts, send an automatic power level notification

0: 0.0W
….
255: 25.5W

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 0 to 255
Default Value 10

1: Lifeline

Send device reset locally notification

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: StatusReport

Send basic report

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: PowerReport

Send meter power report

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: AssignGroupSet

Send Basic set command

Property Value
Configuration ID group_4
Data Type TEXT
Range to