ZW500DM In-wall Smart Meter Dimmer Switch

This describes the Z-Wave device ZW500DM, manufactured by Wenzhou MTLC Electric Appliances Co.,Ltd. with the thing type UID of enerwave_zw500dm_00_000.

In-wall Smart Meter Dimmer Switch

Channels

The following table summarises the channels available for the ZW500DM In-wall Smart Meter Dimmer Switch.

Channel Channel Id Channel Type UID Category Item Type
Sensor (power) sensor_power sensor_power Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW500DM In-wall Smart Meter Dimmer Switch. Detailed information on each parameter can be found below.

Parameter Description
1: Synchronization of load power and LED indicator
8: Instant Energy Autosend Interval (send METER_REPORT)
9: Instant Energy Autosend interval (send SENSOR_MULTILEVEL_REPORT)
10: Accumulated Energy Autosend Interval report (send METER_REPORT)
11: Enable automatic notifications to associated device
12: Minimum change in wattage report
1: Notifications Lifeline
2: StatusReport Send basic report
3: PowerReport PowerReport: Send meter power report

1:

Synchronization of load power and LED indicator

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options Power on, LED off (0)      
  Power on, LED on (1)      

8:

Instant Energy Autosend Interval (send METER_REPORT)

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 0 to 255
Default Value 0

9:

Instant Energy Autosend interval (send SENSOR_MULTILEVEL_REPORT)

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 255
Default Value 0

10:

Accumulated Energy Autosend Interval report (send METER_REPORT)

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 255
Default Value 0

11:

Enable automatic notifications to associated device

Overview

Device will send a notification whenever the is a wattage change

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 1
Options Not report (METER_REPORT) (0)      
  Send (METER_REPORT) only (1)      
  Send (SENSOR_MULTI_LEVEL_REPORT) only (2)      
  Send both (3)      

12:

Minimum change in wattage report

Overview

0-255: 0.0-25.5W

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 0 to 255
Default Value 10

1: Notifications

Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: StatusReport

Send basic report

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: PowerReport

PowerReport: Send meter power report

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.