AN181 Mini Plug Switch with Metering (Gen5)

This describes the Z-Wave device AN181, manufactured by Everspring with the thing type UID of everspring_an181_00_000.

AN181 product image

The AN181 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

The Metering Plug is designed to control the on/off status appliances load in your house. For metering the unit can detect up to 10485.75kW*h and can support wattage, voltage, ampere, and PF detection. The unit can also detect overload upon which the unit will switch off relay and keep LED flashing until power is off and re-applied. At 220-240V voltage, this Plug can support up to 2500W resistive.

Inclusion Information

Press the link key three times within 1.5 seconds to put the unit into inclusion mode.

Exclusion Information

Press the link key three times within 1.5 seconds to put the unit into exclusion mode.

Channels

The following table summarises the channels available for the AN181 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number
Electric meter (amps) meter_current Energy Number
Electric meter (power factor) meter_powerfactor Energy Number
Electric meter (volts) meter_voltage Energy Number
Alarm alarm_general Door Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (power factor)

Indicates the instantaneous power factor.

The meter_powerfactor channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the AN181. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Command value Set Basic Set Command value to be sent to group 2 when switch is turned on
2 Delaying time Set the delaying time to report to Group 1 in seconds
3 Remember status Set whether to remember the last status
4 Interval for wattage auto report Set the interval for wattage auto report in minutes
5 Interval for kW*h auto report Set the interval for kW*h auto report in minutes
6 Auto report load surpasses value Auto report when load surpasses the set value of wattage
7 Auto report change percentage Auto report when the change of wattage surpasses the set percentage
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Command value

Set Basic Set Command value to be sent to group 2 when switch is turned on Meaningful range is 0-99 & 255 where

0 = No command will be sent
1-99 = Turn on switches and dimmers listening to Group 2 to indicated % level (ON for switches)
255 = Turn on switches and dimmers (full power) listening to Group 2

Command will be sent if the mini plug is turned on via the button or if it receives a remote command.

Basic Set Command = 0 (Off) will be sent to Group 2 only if the button is used to turn off the mini plug, not when the mini plug is turned off via remote command. The following option values may be configured, in addition to values in the range 1 to 99 -:

Value Description
0 No Basic Set Command will be sent
255 Basic Set Command ON will be sent

The manufacturer defined default value is 255 (Basic Set Command ON will be sent).

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: Delaying time

Set the delaying time to report to Group 1 in seconds

Values in the range 3 to 25 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Remember status

Set whether to remember the last status

The following option values may be configured -:

Value Description
0 Do not remember
1 Remember

The manufacturer defined default value is 1 (Remember).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Interval for wattage auto report

Set the interval for wattage auto report in minutes

The following option values may be configured, in addition to values in the range 1 to 32767 -:

Value Description
0 Does not report automatically

The manufacturer defined default value is 1.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Interval for kW*h auto report

Set the interval for kW*h auto report in minutes

The following option values may be configured, in addition to values in the range 1 to 32767 -:

Value Description
0 Does not report automatically

The manufacturer defined default value is 60.

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: Auto report load surpasses value

Auto report when load surpasses the set value of wattage

The following option values may be configured, in addition to values in the range 1 to 2500 -:

Value Description
0 Does not report automatically

The manufacturer defined default value is 0 (Does not report automatically).

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: Auto report change percentage

Auto report when the change of wattage surpasses the set percentage

The following option values may be configured, in addition to values in the range 1 to 100 -:

Value Description
0 Does not report automatically

The manufacturer defined default value is 0 (Does not report automatically).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The AN181 supports 2 association groups.

Group 1: Target for automatic reports

Binary Switch Report, Notification Report, Device Reset Locally Notification, Meter Report This group supports 1 nodes.

Group 2: Basic Set

Basic Set, Control:key1, On/Off control (Button1) This group supports 4 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_APPLICATION_STATUS_V1  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_METER_V3  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V0  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_ALARM_V3  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V0  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  