AN181 Mini Plug Switch with Metering (Gen5)

This describes the Z-Wave device AN181, manufactured by Everspring with the thing type UID of everspring_an181_00_000.

Mini Plug Switch with Metering (Gen5)

Overview

The Metering Plug is designed to control the on/off status appliances load in your house. For metering the unit can detect up to 10485.75kW*h and can support wattage, voltage, ampere, and PF detection. The unit can also detect overload upon which the unit will switch off relay and keep LED flashing until power is off and re-applied. At 220-240V voltage, this Plug can support up to 2500W resistive. 

Inclusion Information

Press the link key three times within 1.5 seconds to put the unit into inclusion mode.

Exclusion Information

Press the link key three times within 1.5 seconds to put the unit into exclusion mode.

Channels

The following table summarises the channels available for the AN181 Mini Plug Switch with Metering (Gen5).

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Alarm alarm_general alarm_general Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the AN181 Mini Plug Switch with Metering (Gen5). Detailed information on each parameter can be found below.

Parameter Description
1: Command value Set Basic Set Command value to be sent to group 2 when switch is turned on
2: Delaying time Set the delaying time to report to Group 1 in seconds
3: Remember status Set whether to remember the last status
4: Interval for wattage auto report Set the interval for wattage auto report in minutes
5: Interval for kW*h auto report Set the interval for kW*h auto report in minutes
6: Auto report load surpasses value Auto report when load surpasses the set value of wattage
7: Auto report change percentage Auto report when the change of wattage surpasses the set percentage
1: Target for automatic reports Binary Switch Report, Notification Report, Device Reset Locally Notification, Meter Report
2: Basic Set Basic Set, Control:key1, On/Off control (Button1)

1: Command value

Set Basic Set Command value to be sent to group 2 when switch is turned on

Overview

Meaningful range is 0-99 & 255 where

0 = No command will be sent
1-99 = Turn on switches and dimmers listening to Group 2 to indicated % level (ON for switches)
255 = Turn on switches and dimmers (full power) listening to Group 2

Command will be sent if the mini plug is turned on via the button or if it receives a remote command.

Basic Set Command = 0 (Off) will be sent to Group 2 only if the button is used to turn off the mini plug, not when the mini plug is turned off via remote command.

Property Value      
Configuration ID config_1_2      
Data Type INTEGER      
Range 1 to 99   Default Value 255
Options No Basic Set Command will be sent (0)      
  Basic Set Command ON will be sent (255)      

2: Delaying time

Set the delaying time to report to Group 1 in seconds

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 3 to 25
Default Value 3

3: Remember status

Set whether to remember the last status

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options Do not remember (0)      
  Remember (1)      

4: Interval for wattage auto report

Set the interval for wattage auto report in minutes

Property Value      
Configuration ID config_4_2      
Data Type INTEGER      
Range 1 to 32767   Default Value 1
Options Does not report automatically (0)      

5: Interval for kW*h auto report

Set the interval for kW*h auto report in minutes

Property Value      
Configuration ID config_5_2      
Data Type INTEGER      
Range 1 to 32767   Default Value 60
Options Does not report automatically (0)      

6: Auto report load surpasses value

Auto report when load surpasses the set value of wattage

Property Value      
Configuration ID config_6_2      
Data Type INTEGER      
Range 1 to 2500   Default Value 0
Options Does not report automatically (0)      

7: Auto report change percentage

Auto report when the change of wattage surpasses the set percentage

Property Value      
Configuration ID config_7_1      
Data Type INTEGER      
Range 1 to 100   Default Value 0
Options Does not report automatically (0)      

1: Target for automatic reports

Binary Switch Report, Notification Report, Device Reset Locally Notification, Meter Report

Overview

When powered on, the device will send (Notification Type = 0x08, Event = 0x01) to the node of Group 1. When overload occurs, the device will send (Notification Type = 0x08, Event = 0x08) to the node of Group 1.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Basic Set

Basic Set, Control:key1, On/Off control (Button1)

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.