HAC01 In-Wall Remote Insert

This describes the Z-Wave device HAC01, manufactured by Everspring with the thing type UID of everspring_hac01_00_000.

In-Wall Remote Insert

Channels

The following table summarises the channels available for the HAC01 In-Wall Remote Insert.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the HAC01 In-Wall Remote Insert. Detailed information on each parameter can be found below.

Parameter Description
1: Basic Set Level The Basic Set Command is sent with this value.
2: Amount Of Delay Amount Of Delay (seconds) to send the Basic Set Off command.
1: Switch Input Change Target nodes that receive Basic Set command when the switch input changed.

1: Basic Set Level

The Basic Set Command is sent with this value.

Overview

The Basic Set Command is sent with value to have the receiving device recognize the value for controlled level, for example, if the Basic Set Command sent to dimmer with value, the dimmer would activate the luminance according to the value.

0 : Off
1 – 99 : On (for Binary Switch Device); Dim Level (for Multilevel Switch Device)

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 99
Default Value 99

2: Amount Of Delay

Amount Of Delay (seconds) to send the Basic Set Off command.

Overview

This is applied to determine the delay time setting to send the Basic Set Off command when the manual switch input at NO (open).

Example :
0 : immediately Off
1 – 127 : delay 1 ~ 127 second to Off

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 127
Default Value 1

1: Switch Input Change

Target nodes that receive Basic Set command when the switch input changed.

Overview

The remote module supports association with maximum 5 node for Grouping 1. Grouping 1 supports BASIC_SET.

When the manual switch input is from NC to NO or from NO to NC, HAC01 would send Basic Set Command to the nodes in Grouping 1 to On or Off the controlled device. Basic Set Command:

Manual switch input at NC: Command Class Basic, Basic Set, Value = 0xFF(255)

Manual switch input at NO: Command Class Basic, Basic Set, Value = 0x00(0)

Property Value
Configuration ID group_1
Data Type TEXT