HSM02 Door/Window Contact

This describes the Z-Wave device HSM02, manufactured by Everspring with the thing type UID of everspring_hsm02_00_000.

Door/Window Contact

Channels

The following table summarises the channels available for the HSM02 Door/Window Contact.

Channel Channel Id Channel Type UID Category Item Type
Door / Window Status sensor_door sensor_door Door Contact
Alarm alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the HSM02 Door/Window Contact. Detailed information on each parameter can be found below.

Parameter Description
1: Basic Set Level Value to be sent with a BASIC SET command
2: Configuring the OFF Delay OFF Delay in seconds
3: Staying Awake (for testing)  
1: Target for reports Support ALARM_REPORT, SENSOR_BINARY_SUPPORT
2: Target nodes who receive BASIC_SET command  

1: Basic Set Level

Value to be sent with a BASIC SET command

Overview

0: Off

1-99, 255: Dim Level (Multilevel Switch Device), ON (Binary Switch Device)

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 99
Default Value 99

2: Configuring the OFF Delay

OFF Delay in seconds

Overview

The Configuration parameter that can be used to adjust the amount of delay before the OFF command is transmitted. This parameter can be configured as 0-127, where 0 means sending OFF command immediately and 127 means 127 seconds of delay. 

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 127
Default Value 0

3: Staying Awake (for testing)

Overview

Can be used to determine if the unit stays “awake” all the time. This parameter can be configured as 0 or 1, where 1 means “enabled” and 0 stands for “disabled”

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 1
Default Value 0

1: Target for reports

Support ALARM_REPORT, SENSOR_BINARY_SUPPORT

Overview
Power Applied (Alarm Report)

Once the power has been applied, Alarm Report Command will be sent to Nodes in Grouping 1 to confirm the power applied status for HSM02. 

Power Applied Notice:[Command Class Alarm, Alarm Report, Alarm Type = 0x02, Alarm Level = 0x01]

Magnet status report (Binary Sensor Report)

When the magnets of HSM02 are to be opened, Binary Sensor Report Command (Value = 0xFF) will be sent to Nodes in Grouping 1, and when the magnets are to be closed, Binary Sensor Report Command (Value = 0x00) will be sent as well.

Magnets to be opened: [Command Class Sensor Binary, Sensor Binary Report, Value = 0xFF(255)]
Magnets to be closed: [Command Class Sensor Binary, Sensor Binary Report, Value = 0x00(0)]

Low Battery Report (Alarm Report)

When HSM02 automatically wakes up, it will check the battery usage. When low battery is detected, Alarm Report Command will be sent to Nodes in Grouping 1, afterward, LED will light up for 1 sec to remind user when HSM02 is triggered due to open or close incidents.

Low Battery Report : [Command Class Alarm, Alarm Report, Alarm Type = 0x01, Alarm Level = 0xFF]

Tamper Event Report (Alarm Report)

Press and hold the tamper switch more than 10 seconds then release, the unit will send ALARM REPORT command to the nodes of Grouping 1 to inform them there is a tamper event.

Tamper Event Report : [Command Class Alarm, Alarm Report, Alarm Type = 0x01, Alarm Level = 0x11] 

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Target nodes who receive BASIC_SET command

Overview
Control other Z-Wave Devices 

When door/window is opened, the unit will send BASIC_SET command which contains a value that is adjustable, to the nodes of Grouping 2. For instance, the brightness level of a lamp module can be fixed according to the set value. 

When the door/window is closed, the BASIC_SET command will also be sent to the nodes of Grouping 2. For instance, a lamp module will be turned off after receiving the BASIC_SET command

Basic Set Command:
Event Present: [Command Class Basic, Basic Set, Value = 99 (0x63)] 
Event Clear: [Command Class Basic, Basic Set, Value = 0 (0x00)] 

Property Value
Configuration ID group_2
Data Type TEXT
Range to