SP814 Motion Detector

This describes the Z-Wave device SP814, manufactured by Everspring with the thing type UID of everspring_sp814_00_000.

Motion Detector

Channels

The following table summarises the channels available for the SP814 Motion Detector.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the SP814 Motion Detector. Detailed information on each parameter can be found below.

Parameter Description
1: Basic Set Level Basic Set Level
2: Enable/Disable Detecting The Detecting function can be Disabled or Enabled.
3: Sensitivity Level 1 Means lowest sensitivity and 10 means highest.
4: Re-trigger Interval Adjust the interval of being re-triggered after a trigger
5: Lux Level Minimum Lux Level to provoke trigger
6: On-Off Duration On-Off Duration
1: Reports  
2: Control  

1: Basic Set Level

Basic Set Level

Overview

When Basic Set Command is sent where contains a value, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set command of which value is decisive as to how bright of dim level of lamp module shall be.

Example: 0: OFF

1-99: ON (Binary Switch Device)

Dim Level (Multilevel Switch Device)

Function: Basic Set level

Parameter: 1

Number Size: 1

Range: 0-99

Default: 99 

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 99
Default Value 99

2: Enable/Disable Detecting

The Detecting function can be Disabled or Enabled.

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Enabled (1)      

3: Sensitivity Level

1 Means lowest sensitivity and 10 means highest.

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 1 to 10
Default Value 6

4: Re-trigger Interval

Adjust the interval of being re-triggered after a trigger

Overview

The Configuration parameter that can be used to adjust the interval of being re-triggered after the detector has been triggered as Configuration Parameter #4. No response will be made during this interval if a movement is presented. The time interval can be set between 5 secs to 3600 secs. 

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 5 to 3600
Default Value 5

5: Lux Level

Minimum Lux Level to provoke trigger

Overview

Sets minimum Lux Level of ambient illumination necessary for Motion Detector to trigger.

The user can set a detecting percentage of lux level which determines when the light sensor will be activated. If percentage of lux level of ambient illumination falls below this percentage, and a person moves across or within the protected area, the detector will emit Z-Wave ON Command (i.e. Basic Set Command (Value = Basic Set Level)) to controller and activate connected modules and lighting. Percentage can be set between 1% to 100%.

Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 1 to 100
Default Value 10

6: On-Off Duration

On-Off Duration

Overview

The function of on-off duration setting will be useful if the detector is connected with a module or lighting. The duration determines how long the module/lighting should stay ON. For instance, Lamp Module turns off 100 secs after it has been turned on. This parameter can be configured with the value of 5 through 3600, where 5 means 5 second delay and 3600 means 3600 seconds of delay

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 5 to 255
Default Value 5

1: Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Control

Property Value
Configuration ID group_2
Data Type TEXT
Range to