ST814 Temperature and Humidity Sensor

This describes the Z-Wave device ST814, manufactured by Everspring with the thing type UID of everspring_st814_00_000.

Temperature and Humidity Sensor

Channels

The following table summarises the channels available for the ST814 Temperature and Humidity Sensor.

Channel Channel Id Channel Type UID Category Item Type
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Alarm (CO2) alarm_co2 alarm_co2 Door Switch
Alarm (smoke) alarm_smoke alarm_smoke Door Switch
  battery-level system.battery-level    
Sensor (temperature) 1 sensor_temperature1 sensor_temperature Temperature Number
Sensor (relative humidity) 2 sensor_relhumidity2 sensor_relhumidity Humidity Number

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Sensor (temperature) 1

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ST814 Temperature and Humidity Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Basic Set Level Set basic set value to be on or off
2: Temperature Trigger ON value Temperature level when a ON command is sent out. Set to 99 to disable.
3: Temperature Trigger OFF value Temperature level when a OFF command is sent out. Set to 99 to disable.
4: Humidity Trigger ON value Humidity level when a ON command is sent out. Set to 99 to disable.
5: Humidity Trigger OFF value Humidity level when a OFF command is sent out. Set to 99 to disable.
6: Auto report time Sets the time interval when a sensor report is sent
7: Auto report temperature Sets the temperature change causing a sensor report.
8: Auto report humidity Sets the humidity change causing a sensor report.
1: Reports  
2: Control  

1: Basic Set Level

Set basic set value to be on or off

Overview

0=Disable

1-99=Use Value

Property Value      
Configuration ID config_1_1      
Data Type INTEGER      
Range 0 to 99   Default Value 99
Options Disable (0)      

2: Temperature Trigger ON value

Temperature level when a ON command is sent out. Set to 99 to disable.

Property Value      
Configuration ID config_2_1      
Data Type INTEGER      
Range -20 to 50   Default Value 99
Options Disable (99)      

3: Temperature Trigger OFF value

Temperature level when a OFF command is sent out. Set to 99 to disable.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER      
Range -20 to 50   Default Value 99
Options Disable (99)      

4: Humidity Trigger ON value

Humidity level when a ON command is sent out. Set to 99 to disable.

Property Value      
Configuration ID config_4_1      
Data Type INTEGER      
Range 20 to 90   Default Value 99
Options Disable (99)      

5: Humidity Trigger OFF value

Humidity level when a OFF command is sent out. Set to 99 to disable.

Property Value      
Configuration ID config_5_1      
Data Type INTEGER      
Range 20 to 99   Default Value 99
Options Disable (99)      

6: Auto report time

Sets the time interval when a sensor report is sent

Overview

0 = Disable

1 min - 1439 min = Auto report periodically

Property Value      
Configuration ID config_6_2      
Data Type INTEGER      
Range 0 to 1439   Default Value 0
Options Disable (0)      

7: Auto report temperature

Sets the temperature change causing a sensor report.

Overview

0 = Disable

1 - 70 = Auto report on temperature change

Property Value      
Configuration ID config_7_1      
Data Type INTEGER      
Range 0 to 70   Default Value 0
Options Disable (0)      

8: Auto report humidity

Sets the humidity change causing a sensor report.

Overview

0 = Disable

5 - 70 = Auto report on humidity change

Property Value      
Configuration ID config_8_1      
Data Type INTEGER      
Range 5 to 70   Default Value 0
Options Disable (0)      

1: Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Control

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.