ST815 Illumination Sensor

This describes the Z-Wave device ST815, manufactured by Everspring with the thing type UID of everspring_st815_00_000.

Illumination Sensor

Channels

The following table summarises the channels available for the ST815 Illumination Sensor.

Channel Channel Id Channel Type UID Category Item Type
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the ST815 Illumination Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Basic Set Level Basic Set Level
2: Lux Trigger On Value Lux Trigger On Value
3: Lux Trigger Off Value  
4: Lux Trigger Off Timer Value. Lux Trigger Off Timer Value.
5: Auto Report Time Interval Auto Report Time Interval
6: Auto Report Lux Interval Auto Report Lux Interval
1: Reports  
2: Control  

1: Basic Set Level

Basic Set Level

Overview

Set basic set value to be on or off.

Set to 0 to disable

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 99
Default Value 99

2: Lux Trigger On Value

Lux Trigger On Value

Overview

Lux level when ON command is sent out.

Set to 0 to disable.

Valid values - 30-1000 or 0

Default 30

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 1000
Default Value 300

3: Lux Trigger Off Value

Overview

Lux level when Off command is sent out.

Values 30-1000 or 0

Default 500

Set to 0 to disable.

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 0 to 1000
Default Value 500

4: Lux Trigger Off Timer Value.

Lux Trigger Off Timer Value.

Overview

Timer value in minutes.

Values : 1-480 or 0

Default 240

Set to 0 to disable.

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 0 to 480
Default Value 0

5: Auto Report Time Interval

Auto Report Time Interval

Overview

Time interval in minutes to auto report to association group 1

Valid values 1-1439 minutes or 0

Set to 0 to Disable

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 0 to 1439
Default Value 0

6: Auto Report Lux Interval

Auto Report Lux Interval

Overview

Lux interval step size to auto report to association group 1

Valid Values 30-1000 (Lux)

Set to 0 to Disable

Property Value
Configuration ID config_6_2
Data Type INTEGER
Range 0 to 1000
Default Value 0

1: Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Control

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.