This describes the Z-Wave device VMZ Solar z-wave plus, manufactured by Fakro with the thing type UID of fakro_vmzsolarplus_00_000.

The VMZ Solar z-wave plus supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the VMZ Solar z-wave plus -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Blinds control blinds_control Blinds Rollershutter
Alarm (power) alarm_power Door Switch
Battery Level battery-level Battery Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Blinds control

Provides start / stop control of blinds.

The blinds_control channel supports the Rollershutter item and is in the Blinds category.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 15 configuration parameters available in the VMZ Solar z-wave plus. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 operating mode operating mode
2 winter mode Summer/Winter mode
3 Delay time delay to auto shade
4 Level of sensitivity for day Level of insolation to open/close the shades
5 Temperature Temperature
6 STM active STM AutoShade active
13 Restore last position Restore last position
17 Insolation level Current on autoshade solar panel
21 Motor current Motor current
77 CLOSE current CLOSE current
78 OPEN current OPEN current
79 CLOSE overload current CLOSE overload current
80 OPEN overload current OPEN overload current
99 Restore default config values Restore default config values
100 Autoexclude Autoexclude
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: operating mode

operating mode Operating mode. Available values:

0 - manual

1 - semiauto: goes down automatically but does not go up.

2 - auto The following option values may be configured -:

Value Description
0 manual
1 semiauto
2 auto

The manufacturer defined default value is 0 (manual).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: winter mode

Summer/Winter mode summer mode: go down if sun shines and go up if it is cloudy

winter mode: if temperature is below 0 deg C and sun shines then go up if it is cloudy go down. If temperature is above 0 deg C works as a summer mode The following option values may be configured -:

Value Description
1 summer mode only
2 winter mode

The manufacturer defined default value is 1 (summer mode only).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Delay time

delay to auto shade Delay time in minutes after which the shade is open or closed in auto mode Values in the range 0 to 30 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Level of sensitivity for day

Level of insolation to open/close the shades Level of insolation in mA to open/close the shades in the auto mode Values in the range 3 to 100 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Temperature

Temperature T[oC] = x minus 50 Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_1 and is of type INTEGER. This is a read only parameter.

Parameter 6: STM active

STM AutoShade active

The following option values may be configured -:

Value Description
0 no
1 yes

The manufacturer defined default value is 0 (no).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 13: Restore last position

Restore last position Restore last position or always go down till the end. The following option values may be configured -:

Value Description
1 go down
2 restore last position

The manufacturer defined default value is 1 (go down).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 17: Insolation level

Current on autoshade solar panel Current from autoshade solar panel for loading battery: 0 - 255 mA Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_17_1 and is of type INTEGER. This is a read only parameter.

Parameter 21: Motor current

Motor current Current used by motor: 10[mA] - 2,55[A] Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_21_1 and is of type INTEGER. This is a read only parameter.

Parameter 77: CLOSE current

CLOSE current CLOSE current: 1[mA] - 255[mA] Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_77_1 and is of type INTEGER.

Parameter 78: OPEN current

OPEN current OPEN current: 1[mA] - 255[mA] Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_78_1 and is of type INTEGER.

Parameter 79: CLOSE overload current

CLOSE overload current CLOSE overload current: 10[mA] - 2,55[A] Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_79_1 and is of type INTEGER.

Parameter 80: OPEN overload current

OPEN overload current OPEN overload current: 10[mA] - 2,55[A] Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 99: Restore default config values

Restore default config values Restore default config values. The following option values may be configured -:

Value Description
1 restore default config values
2 user values

The manufacturer defined default value is 2 (user values).

This parameter has the configuration ID config_99_1 and is of type INTEGER.

Parameter 100: Autoexclude

Autoexclude

The following option values may be configured -:

Value Description
1 off
2 on

The manufacturer defined default value is 1 (off).

This parameter has the configuration ID config_100_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The VMZ Solar z-wave plus supports 4 association groups.

Group 1: Lifeline

This group supports 1 nodes.

Group 2: BasicRepeat

This group supports 5 nodes.

Group 3: MultilevelRepeat

This group supports 5 nodes.

Group 4: BasicControl

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1  
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_ALARM_V3  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_NODE_NAMING_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.