FGD212 Dimmer 2

This describes the Z-Wave device FGD212, manufactured by Fibargroup with the thing type UID of fibaro_fgd212_03_005. This version of the device is limited to firmware versions above 3.5

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

FGD212 product image

The FGD212 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the FGD212 -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number   Number
Sensor (power) sensor_power Energy Number
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number
Reset the total power consumption meter_reset Energy Switch
Force initial brightness config_decimal   Decimal
Alarm (heat) alarm_heat   Switch
Alarm (power) alarm_power Door Switch
Alarm (system) alarm_system   Switch
Dimmer 1 switch_dimmer1 DimmableLight Dimmer
Sensor (power) 1 sensor_power1 Energy Number
Electric meter (kWh) 1 meter_kwh1 Energy Number
Electric meter (watts) 1 meter_watts1 Energy Number
Alarm (heat) 1 alarm_heat1   Switch
Alarm (power) 1 alarm_power1 Door Switch
Alarm (system) 1 alarm_system1   Switch
Dimmer 2 switch_dimmer2 DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Sensor (power)

Indicates the energy consumption (kWh).

The sensor_power channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Reset the total power consumption

Reset the meter.

The meter_reset channel supports the Switch item and is in the Energy category.

Force initial brightness

Generic class for configuration parameter.

The config_decimal channel supports the Decimal item.

Alarm (heat)

Indicates if a heat alarm is triggered.

The alarm_heat channel supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Alarm (system)

Indicates if a system alarm is triggered.

The alarm_system channel supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Dimmer 1

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer1 channel supports the Dimmer item and is in the DimmableLight category.

Sensor (power) 1

Indicates the energy consumption (kWh).

The sensor_power1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm (heat) 1

Indicates if a heat alarm is triggered.

The alarm_heat1 channel supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Alarm (power) 1

Indicates if a power alarm is triggered.

The alarm_power1 channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Alarm (system) 1

Indicates if a system alarm is triggered.

The alarm_system1 channel supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Dimmer 2

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer2 channel supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 51 configuration parameters available in the FGD212. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Minimum brightness level The parameter is set automatically during the calibration process. The parameter can be changed manually after the calibration.
2 Maximum brightness level The parameter is set automatically during the calibration process. The parameter can be changed manually after the calibration.
3 Incandescence level of dimmable compact fluorescent lamps Virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%). The Dimmer will set to this value after first switch on. It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources.
4 Incandescence time of dimmable compact fluorescent lamps This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. Setting this parameter to 0 will disable the incandescence functionality. Available settings: 0-255 (0s - 25,5s)
5 Dimming Step at Automatic Control The parameter defines the percentage of a dimming step at automatic control. 1-99
6 Dimming Step Timing at Automatic Control The parameter defines the time of a dimming step at automatic control. Available settings: 0-255 (0s - 2,55s)
7 Dimming Step at Manual Control The parameter defines the percentage of a dimming step at manual control. 1-99
8 Dimming Step Timing at Manual Control The parameter defines the time of a dimming step at manual control. Available settings: 0-255 (0s - 2,55s)
9 Saving state before power failure Saving state before power failure
10 Timer functionality (auto - off). 0 disables the function The parameter defines the setting of the timer. Available settings:1-32767 - time to turn off measured in seconds (1s - 9,1h)
11 ALL ON/ALL OFF function The parameter specifies the available functions.
13 Force auto-calibration Changing the value of this parameter to 1 will force the calibration process. During the calibration parameter is set to 1 and switched to 0 upon completion.
14 Auto-calibration status (read-only parameter) This parameter determines operating mode of the Dimmer (automatic/manual settings).
15 Burnt out bulb detection percentage value of power variation, compared to standard power consumption, measured during the calibration procedure (to be interpreted as load error/burnt out bulb). 1-99, 0 disables the function.
16 Time delay of a burnt out bulb (parameter 15) or overload (parameter 39) detection Time of delay (in seconds) for power variation detection, interpreted as a LOAD ERROR or OVERLOAD detection (too much power connected to the Dimmer 2). 0 disables the function.
19 Forced switch on brightness level If the parameter is active, switching on the Dimmer 2 (S1 single click) will always set this brightness level. 0 disables the function.
20 Inputs Button/Switch configuration Binary inputs type configuration
21 Value sent to associated devices on single click The value sent to associated devices on single click.
22 Change [On-Off] bi-stable keys This function allow user to change [On-Off] bi-stable keys (parameter no. 14) (default value 0)
23 Double click option Double-click set lighting at 100%
24 Command frames sent in 2nd and 3rd association groups (S1 associations) Parameter determines, which actions will not result in sending frames to association groups.
25 Command frames sent in 4th and 5th association groups (S2associations) Parameter determines, which actions will not result in sending frames to association groups.
26 The function of 3-way switch Key no. 2 controls the Dimmer additionally (in 3-way switch mode). Function disabled for parameter 20 set to 2 (roller blind switch).
27 Associations in Z-Wave network security mode This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st Lifeline group.
28 Scene activation functionality SCENE ID depends on the switch type configuration
29 Switch functionality of S1 and S2 Switch S1 and S2 buttons
30 Load control mode The parameter defines the used control mode.
31 Load control mode recognized during auto-calibration Load control mode recognized during auto-calibration
32 On/Off mode This mode is necessary while connecting non-dimmable light sources. Enabling parameter 32 automatically ignores brightening/- dimming time settings.
33 Dimmability of the load (read only) Dimmability of the load (read only)
34 Soft-Start functionality Time required to warm up the filament of halogen bulb.
35 Auto-calibration after power on This parameter determines the trigger of auto-calibration procedure, e.g. power on, load error, etc.
37 Behaviour of the Dimmer after overload or surge  
38 Brightness level correction for flickering loads This parameter specifies the duration of Brightness level correction for flickering loads in seconds. 255 sets the function to “always enabled”. 0 disables the function.
39 Power limit - OVERLOAD Reaching the defined value will result in turning off the load. Parameter 39 is relevant only in a 3-wire connection i or a 2-wire connection for load of cosφ ≥ 0.99. (1 W - 250 W). 0 disables the function.
40 General Purpose Alarm The parameter specifies the response to an alarm.
41 Water Flooding Alarm The parameter specifies the response to an alarm.
42 Smoke, CO or CO2 Alarm The parameter specifies the response to an alarm.
43 Temperature Alarm The parameter specifies the response to an alarm.
44 Time of alarm state Alarm state may be cancelled earlier, as a result of pushing the wall-switch keys or sending the Z-Wave command frame. Available settings: 1-32767 (1s - 32767s).
45 OVERLOAD alarm report (load power consumption too high)
46 LOAD ERROR alarm report (no load, load failure, burnt out bulb)
47 OVERCURRENT alarm report (short circuit, burnt out bulb causing overcurrent)
48 SURGE alarm report (Dimmer output overvoltage)
49 OVERHEAT (critical temperature) and VOLTAGE DROP (low voltage) alarm report  
50 Active power reports The parameter defines the power level change that will result in a new power report being sent. The value is a percentage of the previous report. 0 disables the function.
52 Periodic active power and energy reports Parameter 52 defines a time period between consecutive reports. Timer is reset and counted from zero after each report (1 sec - 32767 sec). 0 disables the function.
53 Energy reports Energy level change which will result in sending a new energy report. Available settings: 1-255 (0,01 - 2,55 kWh). 0 disables the function.
54 Self-measurement The Dimmer may include active power and energy used by itself in reports sent to the main controller.
58 Method of calculating the active power This parameter defines how to calculate active power. It is useful in a case of 2-wire connection with light sources other than resistive. Note: Parameter 58 is set to 0 after forced auto-calibration
59 Approximated power at the maximum brightness level This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level. Available settings: 0-500 (0-500W). Note: Parameter 59 works only when parameter 58 has a value other than 0.
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Minimum brightness level

The parameter is set automatically during the calibration process. The parameter can be changed manually after the calibration.

Values in the range 1 to 98 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Maximum brightness level

The parameter is set automatically during the calibration process. The parameter can be changed manually after the calibration.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Incandescence level of dimmable compact fluorescent lamps

Virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%). The Dimmer will set to this value after first switch on. It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Incandescence time of dimmable compact fluorescent lamps

This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. Setting this parameter to 0 will disable the incandescence functionality. Available settings: 0-255 (0s - 25,5s)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Dimming Step at Automatic Control

The parameter defines the percentage of a dimming step at automatic control. 1-99

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Dimming Step Timing at Automatic Control

The parameter defines the time of a dimming step at automatic control. Available settings: 0-255 (0s - 2,55s)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: Dimming Step at Manual Control

The parameter defines the percentage of a dimming step at manual control. 1-99

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Dimming Step Timing at Manual Control

The parameter defines the time of a dimming step at manual control. Available settings: 0-255 (0s - 2,55s)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: Saving state before power failure

Saving state before power failure

The following option values may be configured -:

Value Description
0 State NOT saved at power failure, all outputs are set to OFF upon powe
1 State saved at power failure, all outputs are set to previous state up

The manufacturer defined default value is 1 (State saved at power failure, all outputs are set to previous state up).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Timer functionality (auto - off). 0 disables the function

The parameter defines the setting of the timer. Available settings:1-32767 - time to turn off measured in seconds (1s - 9,1h)

Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: ALL ON/ALL OFF function

The parameter specifies the available functions.

The following option values may be configured -:

Value Description
0 ALL ON not active, ALL OFF not active
1 ALL ON not active, ALL OFF active
2 ALL ON active, ALL OFF not active
255 ALL ON active, ALL OFF active

The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 13: Force auto-calibration

Changing the value of this parameter to 1 will force the calibration process. During the calibration parameter is set to 1 and switched to 0 upon completion.

The following option values may be configured -:

Value Description
0 readout
1 force auto-calibration of the load without Fibaro Bypass
2 force auto-calibration of the load with Fibaro Bypass

The manufacturer defined default value is 0 (readout).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Auto-calibration status (read-only parameter)

This parameter determines operating mode of the Dimmer (automatic/manual settings).

The following option values may be configured -:

Value Description
0 calibration procedure not performed or Dimmer operates on manual setti
1 Dimmer operates on auto-calibration settings

The manufacturer defined default value is 0 (calibration procedure not performed or Dimmer operates on manual setti).

This parameter has the configuration ID config_14_1 and is of type INTEGER. This is a read only parameter.

Parameter 15: Burnt out bulb detection

percentage value of power variation, compared to standard power consumption, measured during the calibration procedure (to be interpreted as load error/burnt out bulb). 1-99, 0 disables the function.

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: Time delay of a burnt out bulb (parameter 15) or overload (parameter 39) detection

Time of delay (in seconds) for power variation detection, interpreted as a LOAD ERROR or OVERLOAD detection (too much power connected to the Dimmer 2). 0 disables the function.

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_16_2 and is of type INTEGER.

Parameter 19: Forced switch on brightness level

If the parameter is active, switching on the Dimmer 2 (S1 single click) will always set this brightness level. 0 disables the function.

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Parameter 20: Inputs Button/Switch configuration

Binary inputs type configuration

The following option values may be configured -:

Value Description
0 Mono-stable input (button)
1 Bi-stable input (switch)
2 Roller blind switch (UP / DOWN)

The manufacturer defined default value is 0 (Mono-stable input (button)).

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 21: Value sent to associated devices on single click

The value sent to associated devices on single click.

The following option values may be configured -:

Value Description
0 0xFF value is sent, which will set associated devices to their last sa
1 current Dimmer 2 state is sent, which will synchronize brightness leve

The manufacturer defined default value is 0 (0xFF value is sent, which will set associated devices to their last sa).

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 22: Change [On-Off] bi-stable keys

This function allow user to change [On-Off] bi-stable keys (parameter no. 14) (default value 0)

The following option values may be configured -:

Value Description
0 Device changes status on key status change
1 Device status depends on key status; ON when the key is ON, OFF when t

The manufacturer defined default value is 0 (Device changes status on key status change).

This parameter has the configuration ID config_22_1 and is of type INTEGER.

Parameter 23: Double click option

Double-click set lighting at 100%

The following option values may be configured -:

Value Description
0 Disable double click
1 Enable double click

The manufacturer defined default value is 1 (Enable double click).

This parameter has the configuration ID config_23_1 and is of type INTEGER.

Parameter 24: Command frames sent in 2nd and 3rd association groups (S1 associations)

Parameter determines, which actions will not result in sending frames to association groups.

The following option values may be configured -:

Value Description
0 all actions send to association groups
1 do not send when switching ON (single click)
2 do not send when switching OFF (single click)
4 do not send when changing dimming level (holding and releasing)
8 do not send on double click
16 send 0xFF value on double click

The manufacturer defined default value is 0 (all actions send to association groups).

This parameter has the configuration ID config_24_1 and is of type INTEGER.

Parameter 25: Command frames sent in 4th and 5th association groups (S2associations)

Parameter determines, which actions will not result in sending frames to association groups.

The following option values may be configured -:

Value Description
0 all actions send to association groups
1 do not send when switching ON (single click)
2 do not send when switching OFF (single click)
4 do not send when changing dimming level (holding and releasing)
8 do not send on double click
16 send 0xFF value on double click

The manufacturer defined default value is 0 (all actions send to association groups).

This parameter has the configuration ID config_25_1 and is of type INTEGER.

Parameter 26: The function of 3-way switch

Key no. 2 controls the Dimmer additionally (in 3-way switch mode). Function disabled for parameter 20 set to 2 (roller blind switch).

The following option values may be configured -:

Value Description
0 3-way switch function for S2 disabled
1 3-way switch function for S2 enabled

The manufacturer defined default value is 0 (3-way switch function for S2 disabled).

This parameter has the configuration ID config_26_1 and is of type INTEGER.

Parameter 27: Associations in Z-Wave network security mode

This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st Lifeline group.

The following option values may be configured -:

Value Description
0 all groups (II-V) sent as non-secure
1 2nd group sent as secure
2 3rd group sent as secure
4 4th group sent as secure
8 5th group sent as secure
15 all groups (II-V) sent as secure

The manufacturer defined default value is 15 (all groups (II-V) sent as secure).

This parameter has the configuration ID config_27_1 and is of type INTEGER.

Parameter 28: Scene activation functionality

SCENE ID depends on the switch type configuration

The following option values may be configured -:

Value Description
0 Scene functionality deactivated
1 Scene functionality activated

The manufacturer defined default value is 0 (Scene functionality deactivated).

This parameter has the configuration ID config_28_1 and is of type INTEGER.

Parameter 29: Switch functionality of S1 and S2

Switch S1 and S2 buttons

The following option values may be configured -:

Value Description
0 standard mode
1 S1 operates as S2, S2 operates as S1

The manufacturer defined default value is 0 (standard mode).

This parameter has the configuration ID config_29_1 and is of type INTEGER.

Parameter 30: Load control mode

The parameter defines the used control mode.

The following option values may be configured -:

Value Description
0 forced leading edge control
1 forced trailing edge control
2 control mode selected automatically (based on auto-calibration)

The manufacturer defined default value is 2 (control mode selected automatically (based on auto-calibration)).

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Parameter 31: Load control mode recognized during auto-calibration

Load control mode recognized during auto-calibration

The following option values may be configured -:

Value Description
0 leading edge control
1 trailing edge control

The manufacturer defined default value is 0 (leading edge control).

This parameter has the configuration ID config_31_1 and is of type INTEGER. This is a read only parameter.

Parameter 32: On/Off mode

This mode is necessary while connecting non-dimmable light sources. Enabling parameter 32 automatically ignores brightening/- dimming time settings.

The following option values may be configured -:

Value Description
0 on/off mode disabled (dimming is possible)
1 on/off mode enabled (dimming is not possible)
2 mode selected automatically

The manufacturer defined default value is 2 (mode selected automatically).

This parameter has the configuration ID config_32_1 and is of type INTEGER.

Parameter 33: Dimmability of the load (read only)

Dimmability of the load (read only)

The following option values may be configured -:

Value Description
0 Load recognized as dimmable
1 Load recognized as non-dimmable

The manufacturer defined default value is 0 (Load recognized as dimmable).

This parameter has the configuration ID config_33_1 and is of type INTEGER. This is a read only parameter.

Parameter 34: Soft-Start functionality

Time required to warm up the filament of halogen bulb.

The following option values may be configured -:

Value Description
0 no soft-start
1 short soft-start (0,1s)
2 long soft-start (0,5s)

The manufacturer defined default value is 1 (short soft-start (0,1s)).

This parameter has the configuration ID config_34_1 and is of type INTEGER.

Parameter 35: Auto-calibration after power on

This parameter determines the trigger of auto-calibration procedure, e.g. power on, load error, etc.

The following option values may be configured -:

Value Description
0 No auto-calibration of the load after power on
1 Auto-calibration performed after first power on
2 Auto-calibration performed after each power on
3 Auto-calibration performed after first power on or after each LOAD ERR
4 Auto-calibration performed after each power on or after each LOAD ERRO

The manufacturer defined default value is 1 (Auto-calibration performed after first power on).

This parameter has the configuration ID config_35_1 and is of type INTEGER.

Parameter 37: Behaviour of the Dimmer after overload or surge

The following option values may be configured -:

Value Description
0 device permanently disabled until re-enabling by comand or push-button
1 three attempts to turn on the load

The manufacturer defined default value is 1 (three attempts to turn on the load).

This parameter has the configuration ID config_37_1 and is of type INTEGER.

Parameter 38: Brightness level correction for flickering loads

This parameter specifies the duration of Brightness level correction for flickering loads in seconds. 255 sets the function to “always enabled”. 0 disables the function. Correction reduces spontaneous flickering of some capacitive load (e.g. dimmable LEDs) at certain brightness levels in 2-wire installation.

In countries using ripple-control, correction may cause changes in brightness. In this case it is necessary to disable correction or adjust time of correction for flickering loads. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_38_2 and is of type INTEGER.

Parameter 39: Power limit - OVERLOAD

Reaching the defined value will result in turning off the load. Parameter 39 is relevant only in a 3-wire connection i or a 2-wire connection for load of cosφ ≥ 0.99. (1 W - 250 W). 0 disables the function.

Values in the range 0 to 250 may be set.

The manufacturer defined default value is 250.

This parameter has the configuration ID config_39_2 and is of type INTEGER.

Parameter 40: General Purpose Alarm

The parameter specifies the response to an alarm.

The following option values may be configured -:

Value Description
0 No reaction
1 Turn on the load
2 Turn off the load
3 Load blinking

The manufacturer defined default value is 3 (Load blinking).

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 41: Water Flooding Alarm

The parameter specifies the response to an alarm.

The following option values may be configured -:

Value Description
0 No reaction
1 Turn on the load
2 Turn off the load
3 Load blinking

The manufacturer defined default value is 2 (Turn off the load).

This parameter has the configuration ID config_41_1 and is of type INTEGER.

Parameter 42: Smoke, CO or CO2 Alarm

The parameter specifies the response to an alarm.

The following option values may be configured -:

Value Description
0 No reaction
1 Turn on the load
2 Turn off the load
3 Load blinking

The manufacturer defined default value is 3 (Load blinking).

This parameter has the configuration ID config_42_1 and is of type INTEGER.

Parameter 43: Temperature Alarm

The parameter specifies the response to an alarm.

The following option values may be configured -:

Value Description
0 No reaction
1 Turn on the load
2 Turn off the load
3 Load blinking

The manufacturer defined default value is 1 (Turn on the load).

This parameter has the configuration ID config_43_1 and is of type INTEGER.

Parameter 44: Time of alarm state

Alarm state may be cancelled earlier, as a result of pushing the wall-switch keys or sending the Z-Wave command frame. Available settings: 1-32767 (1s - 32767s).

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_44_2 and is of type INTEGER.

Parameter 45: OVERLOAD alarm report

(load power consumption too high)

The following option values may be configured -:

Value Description
0 No reaction
1 Send an alarm frame

The manufacturer defined default value is 1 (Send an alarm frame).

This parameter has the configuration ID config_45_1 and is of type INTEGER.

Parameter 46: LOAD ERROR alarm report

(no load, load failure, burnt out bulb)

The following option values may be configured -:

Value Description
0 No reaction
1 Send an alarm frame

The manufacturer defined default value is 1 (Send an alarm frame).

This parameter has the configuration ID config_46_1 and is of type INTEGER.

Parameter 47: OVERCURRENT alarm report

(short circuit, burnt out bulb causing overcurrent)

The following option values may be configured -:

Value Description
0 No reaction
1 Send an alarm frame

The manufacturer defined default value is 1 (Send an alarm frame).

This parameter has the configuration ID config_47_1 and is of type INTEGER.

Parameter 48: SURGE alarm report

(Dimmer output overvoltage)

The following option values may be configured -:

Value Description
0 No reaction
1 Send an alarm frame

The manufacturer defined default value is 1 (Send an alarm frame).

This parameter has the configuration ID config_48_1 and is of type INTEGER.

Parameter 49: OVERHEAT (critical temperature) and VOLTAGE DROP (low voltage) alarm report

The following option values may be configured -:

Value Description
0 No reaction
1 Send an alarm frame

The manufacturer defined default value is 1 (Send an alarm frame).

This parameter has the configuration ID config_49_1 and is of type INTEGER.

Parameter 50: Active power reports

The parameter defines the power level change that will result in a new power report being sent. The value is a percentage of the previous report. 0 disables the function.

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_50_1 and is of type INTEGER.

Parameter 52: Periodic active power and energy reports

Parameter 52 defines a time period between consecutive reports. Timer is reset and counted from zero after each report (1 sec - 32767 sec). 0 disables the function.

Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 3600.

This parameter has the configuration ID config_52_2 and is of type INTEGER.

Parameter 53: Energy reports

Energy level change which will result in sending a new energy report. Available settings: 1-255 (0,01 - 2,55 kWh). 0 disables the function.

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_53_2 and is of type INTEGER.

Parameter 54: Self-measurement

The Dimmer may include active power and energy used by itself in reports sent to the main controller.

The following option values may be configured -:

Value Description
0 Self-measurement inactive
1 Self-measurement active

The manufacturer defined default value is 0 (Self-measurement inactive).

This parameter has the configuration ID config_54_1 and is of type INTEGER.

Parameter 58: Method of calculating the active power

This parameter defines how to calculate active power. It is useful in a case of 2-wire connection with light sources other than resistive. Note: Parameter 58 is set to 0 after forced auto-calibration

The following option values may be configured -:

Value Description
0 measurement based on the standard algorithm
1 approximation based on the calibration data
2 approximation based on the control angle

The manufacturer defined default value is 0 (measurement based on the standard algorithm).

This parameter has the configuration ID config_58_1 and is of type INTEGER.

Parameter 59: Approximated power at the maximum brightness level

This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level. Available settings: 0-500 (0-500W). Note: Parameter 59 works only when parameter 58 has a value other than 0.

Values in the range 0 to 500 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_59_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The FGD212 supports 5 association groups.

Group 1: Lifeline

This group supports 1 nodes.

Group 2: Sends BASIC SET command class frame according to the state of the devi

This group supports 10 nodes.

Group 3: Sends BASIC SET command class frame according to the state of the devi

This group supports 10 nodes.

Group 4: Sends BASIC SET command class frame according to the state of the devi

This group supports 10 nodes.

Group 5: Sends BASIC SET command class frame according to the state of the devi

This group supports 10 nodes.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_APPLICATION_STATUS_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V0| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V4| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_CRC_16_ENCAP_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V0| | | COMMAND_CLASS_ALARM_V5| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V0| | | COMMAND_CLASS_PROTECTION_V2| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_SECURITY_V1| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| Linked to BASIC| | COMMAND_CLASS_SENSOR_MULTILEVEL_V4| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ALARM_V5| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| |

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Linked to BASIC
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  