FGRGBW RGBW Controller

This describes the Z-Wave device FGRGBW, manufactured by Fibargroup with the thing type UID of fibaro_fgrgbw_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

FGRGBW product image

The FGRGBW supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the FGRGBW -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Sensor (power) sensor_power Energy Number
Electric meter (watts) meter_watts Energy Number
Electric meter (kWh) meter_kwh Energy Number
Color color_color   Color
Start animation scene_number   Number
Red switch_dimmer2 DimmableLight Dimmer
Green switch_dimmer3 DimmableLight Dimmer
Blue switch_dimmer4 DimmableLight Dimmer
White switch_dimmer5 DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Sensor (power)

Indicates the energy consumption (kWh).

The sensor_power channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Color

The color channel allows to control the color of a light. It is also possible to dim values and switch the light on and off.

The color_color channel supports the Color item.

Start animation

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Red

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer2 channel supports the Dimmer item and is in the DimmableLight category.

Green

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer3 channel supports the Dimmer item and is in the DimmableLight category.

Blue

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer4 channel supports the Dimmer item and is in the DimmableLight category.

White

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer5 channel supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 20 configuration parameters available in the FGRGBW. Detailed information on each parameter can be found in the sections below.

| Param | Name | Description | |——-|——-|————-| | 1 | ALL ON / ALL OFF function activation | Activation/deactivation of ALL ON/ALL OFF functions. | | 6 | Associations command class choice | Associations command class choice. By default, Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP. Default setting: Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP | | 8 | Outputs state change mode | MODE1, Example: change saturation level from 0% to 99% Parameter 9: Step = 5 Parameter 10: Time between steps: 10ms. Default setting: MODE1 | | 9 | Step value (relevant for MODE1) | Step value (relevant for MODE1).
Default setting: 1
Available settings: 1 - 255. | | 10 | Time between steps (relevant for MODE1) | Time between steps (relevant for MODE1).
Default setting: 10 ms
0 - immediate change of state
Available settings: 1 - 60000 ms. | | 11 | Time for changing from start to end value | Step value (relevant for MODE1).
Default setting: 67 (3s)
0: immediate change
1-63: 20-126 [ms] value*20ms
65-127: 1-63 [s] (value-64)*1s
129-191: 10-630 [s] (value-128)*10s | | 12 | Maximum Brightening level | Maximum Brightening level.
Default setting: 255
Available settings: 3 - 255. | | 13 | Minimum dim level | Minimum dim level. Default setting: 2 Available settings: 3 - 255. | | 14 | Inputs/Outputs configuration - relevant for main controllers other than Home Center 2 only | Inputs/Outputs configuration - relevant for main controllers other than Home Center 2 only.
Default setting: 4369
Controlled device: RGBW, toggle switch inputs (NORMAL MODE). | | 16 | Remember device status after power failure | Define how will the Plug react after the power supply is back on. Default setting: 1 Available settings: 0 - Device does not memorize its state aft | | 30 | Alarm of any type (General alarm, flood alarm, smoke alarm: CO, CO2, temperature alarm.) | Alarm of any type (General alarm, flood alarm, smoke alarm: CO, CO2, temperature alarm.) Default setting: INACTIVE | | 38 | Alarm sequence program | Alarm sequence program.
Default setting: 10
1-10 specifies alarm program number. | | 39 | Active PROGRAM alarm time | IActive PROGRAM alarm time.
Default setting: 600s
1-65534 specifies alarm time in seconds. | | 42 | Command class reporting Outputs status change | Command class reporting Outputs status change. Default setting: 0 | | 43 | Reporting 0-10v analog inputs change threshold | Parameter defines a value by which input voltage must change in order to be reported to the main controller.
New value is calculated based on last reported value.
Default setting: 5 | | 44 | Power load reporting frequency | Parameter defines Time between reports. The report will be sent if last reported value differs from the current value, else reports will also be sent in case of polling.
Default setting: 3 600 (s) | | 45 | Reporting Changes in energy consumed by controlled devices | Defines the required change in power to generate an unsolicited power report.
New, reported energy value is calculated based on last reported value.
Default setting: 10 (0,1 kWh). | | 71 | Response to BRIGHTNESS set to 0% | Response to BRIGHTNESS set to 0%. Default setting: 1 | | 72 | Starting animation program | Starting animation programm. Starting predefined program when device set to work in RGB/RGBW mode (parameter 14) - relevant for main controllers other than Home Center 2 only. Default setting: 1 | | 73 | Triple click action | Triple click action. Default setting: 0 | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |

Parameter 1: ALL ON / ALL OFF function activation

Activation/deactivation of ALL ON/ALL OFF functions. By default, ALL ON active ALL OFF active. The following option values may be configured -:

Value Description
-1 ALL ON active ALL OFF active
0 ALL ON inactive ALL OFF inactive
1 ALL ON inactive ALL OFF active
2 ALL ON active ALL OFF inactive

The manufacturer defined default value is 255.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 6: Associations command class choice

Associations command class choice. By default, Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP. Default setting: Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP

The following option values may be configured -:

Value Description
0 Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP
1 Normal (RGBW) - COLOR_CONTROL_SET/START/STOP_STATE_CHANGE
2 Normal (RGBW) - COLOR_CONTROL_SET
3 Brightness - BASIC_SET/SWITCH_MULTILEVEL_START/STOP
4 Rainbow (RGBW) - COLOR_CONTROL_SET

The manufacturer defined default value is 0 (Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 8: Outputs state change mode

MODE1, Example: change saturation level from 0% to 99% Parameter 9: Step = 5 Parameter 10: Time between steps: 10ms. Default setting: MODE1

The following option values may be configured -:

Value Description
0 MODE1 (related parameters: 9-step value, 10-time between steps)
1 MODE2 (related parameters: 11-time to change value, relevant for RGB/R

The manufacturer defined default value is 0 (MODE1 (related parameters: 9-step value, 10-time between steps)).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Step value (relevant for MODE1)

Step value (relevant for MODE1).
Default setting: 1
Available settings: 1 - 255.

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Time between steps (relevant for MODE1)

Time between steps (relevant for MODE1).
Default setting: 10 ms
0 - immediate change of state
Available settings: 1 - 60000 ms.

Values in the range 0 to 60000 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Time for changing from start to end value

Step value (relevant for MODE1).
Default setting: 67 (3s)
0: immediate change
1-63: 20-126 [ms] value*20ms
65-127: 1-63 [s] (value-64)*1s
129-191: 10-630 [s] (value-128)*10s

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 67.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Maximum Brightening level

Maximum Brightening level.
Default setting: 255
Available settings: 3 - 255.

Values in the range 3 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Minimum dim level

Minimum dim level. Default setting: 2 Available settings: 3 - 255.

Values in the range 2 to 255 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Inputs/Outputs configuration - relevant for main controllers other than Home Center 2 only

Inputs/Outputs configuration - relevant for main controllers other than Home Center 2 only.
Default setting: 4369
Controlled device: RGBW, toggle switch inputs (NORMAL MODE).

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 4369.

This parameter has the configuration ID config_14_2 and is of type INTEGER.

Parameter 16: Remember device status after power failure

Define how will the Plug react after the power supply is back on. Default setting: 1 Available settings: 0 - Device does not memorize its state aft

The following option values may be configured -:

Value Description
0 Do not remember state
1 Remember state before power failure

The manufacturer defined default value is 1 (Remember state before power failure).

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 30: Alarm of any type (General alarm, flood alarm, smoke alarm: CO, CO2, temperature alarm.)

Alarm of any type (General alarm, flood alarm, smoke alarm: CO, CO2, temperature alarm.) Default setting: INACTIVE

The following option values may be configured -:

Value Description
0 INACTIVE - the device doesn’t respond to alarm frames
1 ALARM ON - the device turns on once alarm is detected (all channels se
2 ALARM OFF - the device turns off once alarm is detected (all channels
3 ALARM PROGRAM - alarm sequence turns on (program selected in parameter

The manufacturer defined default value is 0 (INACTIVE - the device doesn’t respond to alarm frames).

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Parameter 38: Alarm sequence program

Alarm sequence program.
Default setting: 10
1-10 specifies alarm program number.

Values in the range 1 to 10 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_38_1 and is of type INTEGER.

Parameter 39: Active PROGRAM alarm time

IActive PROGRAM alarm time.
Default setting: 600s
1-65534 specifies alarm time in seconds.

Values in the range 1 to 65534 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_39_2 and is of type INTEGER.

Parameter 42: Command class reporting Outputs status change

Command class reporting Outputs status change. Default setting: 0

The following option values may be configured -:

Value Description
0 Reporting as a result of inputs and controllers actions (SWITCH MULTIL
1 Reporting as a result of inputs actions (SWITCH MULTILEVEL)
2 Reporting as a result of inputs actions (COLOR CONTROL)

The manufacturer defined default value is 0 (Reporting as a result of inputs and controllers actions (SWITCH MULTIL).

This parameter has the configuration ID config_42_1 and is of type INTEGER.

Parameter 43: Reporting 0-10v analog inputs change threshold

Parameter defines a value by which input voltage must change in order to be reported to the main controller.
New value is calculated based on last reported value.
Default setting: 5

Values in the range 1 to 100 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_43_1 and is of type INTEGER.

Parameter 44: Power load reporting frequency

Parameter defines Time between reports. The report will be sent if last reported value differs from the current value, else reports will also be sent in case of polling.
Default setting: 3 600 (s)

Values in the range 1 to 65534 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_44_2 and is of type INTEGER.

Parameter 45: Reporting Changes in energy consumed by controlled devices

Defines the required change in power to generate an unsolicited power report.
New, reported energy value is calculated based on last reported value.
Default setting: 10 (0,1 kWh).

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_45_1 and is of type INTEGER.

Parameter 71: Response to BRIGHTNESS set to 0%

Response to BRIGHTNESS set to 0%. Default setting: 1

The following option values may be configured -:

Value Description
0 illumination colour set to white (all channels controlled together)
1 last set colour is memorized

The manufacturer defined default value is 1 (last set colour is memorized).

This parameter has the configuration ID config_71_1 and is of type INTEGER.

Parameter 72: Starting animation program

Starting animation programm. Starting predefined program when device set to work in RGB/RGBW mode (parameter 14) - relevant for main controllers other than Home Center 2 only. Default setting: 1

Values in the range 1 to 10 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_72_1 and is of type INTEGER.

Parameter 73: Triple click action

Triple click action. Default setting: 0

The following option values may be configured -:

Value Description
0 NODE INFO control frame is sent
1 starting favourite program

The manufacturer defined default value is 0 (NODE INFO control frame is sent).

This parameter has the configuration ID config_73_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The FGRGBW supports 5 association groups.

Group 1: Assigned to IN1 input

This group supports 5 nodes.

Group 2: Assigned to IN2 input

This group supports 5 nodes.

Group 3: Assigned to IN3 input

This group supports 5 nodes.

Group 4: Assigned to IN4 input

This group supports 5 nodes.

Group 5: Reports device status

This group supports 1 nodes.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V2| | | COMMAND_CLASS_METER_V2| | | COMMAND_CLASS_SWITCH_COLOR_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| Linked to BASIC|

Endpoint 2

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| Linked to BASIC|

Endpoint 3

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| Linked to BASIC|

Endpoint 4

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| Linked to BASIC|

Endpoint 5

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC