The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

FGS211 Relay Switch 1x3kW

This describes the Z-Wave device FGS211, manufactured by Fibargroup with the thing type UID of fibaro_fgs211_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

FGS211 product image

The FGS211 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the FGS211 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Switch 1 switch_binary1 Switch Switch
Switch 2 switch_binary2 Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 13 configuration parameters available in the FGS211. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Enable/Disable ALL ON/OFF Activate/Deactive ALL ON/OFF
3 Enable/Disable OFF-delay Activate/Deactivate Automatic turning off relay after set time
4 Relay 1: OFF-delay time (10ms steps) Automatic turning off relay 1 after set time, in 10ms increments (default: 200ms)
6 Separation of association sending (key 1) Activate/Deactivate association sending for group 1 - Also see param #16
13 Inputs behaviour In case of bi-stable switches, define their behaviour (toggle or follow)
14 Inputs Button/Switch configuration Binary inputs type configuration
15 Dimmer/Roller shutter control Enable/Disable operation of dimmer or roller shutter devices associated to group 1. Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation
16 Saving state before power failure Saving state before power failure
30 Relay 1: Response to General Alarm  
31 Relay 1: Response to Water Flood Alarm  
32 Relay 1: Response to Smoke, CO, CO2 Alarm  
33 Relay 1: Response to Temperature Alarm  
39 ALARM FLASHING alarm time Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame

Parameter 1: Enable/Disable ALL ON/OFF

Activate/Deactive ALL ON/OFF

The following option values may be configured -:

Value Description
-1 ALL ON active / ALL OFF active
0 ALL ON disabled / ALL OFF disabled
1 ALL ON disabled / ALL OFF active
2 ALL ON active / ALL OFF disabled

The manufacturer defined default value is 255.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 3: Enable/Disable OFF-delay

Activate/Deactivate Automatic turning off relay after set time

The following option values may be configured -:

Value Description
0 Auto OFF disabled for both relays
1 Auto OFF active only for relay 1

The manufacturer defined default value is 0 (Auto OFF disabled for both relays).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Relay 1: OFF-delay time (10ms steps)

Automatic turning off relay 1 after set time, in 10ms increments (default: 200ms)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 20.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 6: Separation of association sending (key 1)

Activate/Deactivate association sending for group 1 - Also see param #16

The following option values may be configured -:

Value Description
0 Map status to all devices in group 1
1 Map OFF status to all devices in group 1, Double click on key 1 will s
2 Map OFF status to all devices in group 1, Double click on key 1 will s

The manufacturer defined default value is 0 (Map status to all devices in group 1).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 13: Inputs behaviour

In case of bi-stable switches, define their behaviour (toggle or follow)

The following option values may be configured -:

Value Description
0 Toggle
1 Follow switch contact (closed=ON, open=OFF)

The manufacturer defined default value is 0 (Toggle).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Inputs Button/Switch configuration

Binary inputs type configuration

The following option values may be configured -:

Value Description
0 Mono-stable input (button)
1 Bi-stable input (switch)

The manufacturer defined default value is 1 (Bi-stable input (switch)).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Dimmer/Roller shutter control

Enable/Disable operation of dimmer or roller shutter devices associated to group 1. Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation

The following option values may be configured -:

Value Description
0 Disable Dimmer/Roller shutter control
1 Enable Dimmer/Roller shutter control

The manufacturer defined default value is 0 (Disable Dimmer/Roller shutter control).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: Saving state before power failure

Saving state before power failure

The following option values may be configured -:

Value Description
0 State NOT saved at power failure, all outputs are set to OFF upon powe
1 State saved at power failure, all outputs are set to previous state up

The manufacturer defined default value is 1 (State saved at power failure, all outputs are set to previous state up).

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 30: Relay 1: Response to General Alarm

The following option values may be configured -:

Value Description
0 DEACTIVATION - no response to alarm frames
1 ALARM RELAY ON - relay will turn ON upon receipt of alarm frame
2 ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame
3 ALARM FLASHING - relay will turn ON and OFF periodically (see param.39

The manufacturer defined default value is 3 (ALARM FLASHING - relay will turn ON and OFF periodically (see param.39).

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Parameter 31: Relay 1: Response to Water Flood Alarm

The following option values may be configured -:

Value Description
0 DEACTIVATION - no response to alarm frames
1 ALARM RELAY ON - relay will turn ON upon receipt of alarm frame
2 ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame
3 ALARM FLASHING - relay will turn ON and OFF periodically (see param.39

The manufacturer defined default value is 2 (ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame).

This parameter has the configuration ID config_31_1 and is of type INTEGER.

Parameter 32: Relay 1: Response to Smoke, CO, CO2 Alarm

The following option values may be configured -:

Value Description
0 DEACTIVATION - no response to alarm frames
1 ALARM RELAY ON - relay will turn ON upon receipt of alarm frame
2 ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame
3 ALARM FLASHING - relay will turn ON and OFF periodically (see param.39

The manufacturer defined default value is 3 (ALARM FLASHING - relay will turn ON and OFF periodically (see param.39).

This parameter has the configuration ID config_32_1 and is of type INTEGER.

Parameter 33: Relay 1: Response to Temperature Alarm

The following option values may be configured -:

Value Description
0 DEACTIVATION - no response to alarm frames
1 ALARM RELAY ON - relay will turn ON upon receipt of alarm frame
2 ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame
3 ALARM FLASHING - relay will turn ON and OFF periodically (see param.39

The manufacturer defined default value is 1 (ALARM RELAY ON - relay will turn ON upon receipt of alarm frame).

This parameter has the configuration ID config_33_1 and is of type INTEGER.

Parameter 39: ALARM FLASHING alarm time

Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_39_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The FGS211 supports 3 association groups.

Group 1: Switch 1

This group supports 16 nodes.

Group 2: Switch 2

This group supports 16 nodes.

Group 3: Controller Updates

This group supports 1 nodes.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC|

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.