FGBS001 Universal Binary Sensor

This describes the Z-Wave device FGBS001, manufactured by Fibargroup with the thing type UID of fibaro_fgbs001_00_000.

Universal Binary Sensor

Channels

The following table summarises the channels available for the FGBS001 Universal Binary Sensor.

Channel Channel Id Channel Type UID Category Item Type
Scene Number scene_number scene_number   Number
Binary Sensor 1 sensor_binary1 sensor_binary Door Switch
Alarm 1 alarm_general1 alarm_general Door Switch
Binary Sensor 2 sensor_binary2 sensor_binary Door Switch
Alarm 2 alarm_general2 alarm_general Door Switch
Temperature 1 sensor_temperature3 sensor_temperature Temperature Number
Temperature 2 sensor_temperature4 sensor_temperature Temperature Number
Temperature 3 sensor_temperature5 sensor_temperature Temperature Number
Temperature 4 sensor_temperature6 sensor_temperature Temperature Number

Temperature 1

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Temperature 2

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Temperature 3

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Temperature 4

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the FGBS001 Universal Binary Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: IN1 Alarm Cancellation Delay Input I alarm cancellation delay.
2: IN2 Alarm Cancellation Delay Input 2 alarm cancellation delay.
3: Type of input no. 1 Type of input no. 1, what the input 1 will report if no contact is made
4: Type of input no. 2 Type of input no. 2, what the input 2 will report if no contact is made
5: Type of transmitted control frame for association group 1 Type of transmitted control frame for association group 1.
6: Type of transmitted control frame for association group 2 Type of transmitted control frame for association group 2
7: Forced Level of Dimming group 1 Value of the parameter specifying the forced levels.
8: Forced Level of Dimming group 2 Value of the parameter specifying forced levels.
9: Deactivate transmission of frame canceling alarm Deactivating transmission of the frame cancelling the alarm
10: Interval between successive readings of temperature sensors Interval between successive readings of temperature
11: Interval betw. forcing to send report concerning the temp. The forced report is sent immediately after
12: Insensitiveness to temperature changes. This is the maximum acceptable difference between
13: Transmitting the alarm or control frame broadcast mode Transmitting the alarm or control frame in ‘broadcast’ mode
14: Scene activation Enable/Disable scene functionality.
1: Input 1  
2: Input 2  
3: Controller Updates Reports on the condition of the device

1: IN1 Alarm Cancellation Delay

Input I alarm cancellation delay.

Overview

Additional delay after an alarm from input IN1 has ceased. The parameter allows you to specify additional time, after which the input no. 1 alarm is cancelled once its violation has ceased.

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

2: IN2 Alarm Cancellation Delay

Input 2 alarm cancellation delay.

Overview

Additional delay after an alarm from input IN2 has ceased. The parameter allows you to specify additional time, after which the input no. 2 alarm is cancelled once its violation has ceased.

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

3: Type of input no. 1

Type of input no. 1, what the input 1 will report if no contact is made

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options NO (Normal Open) (0)      
  NC (Normal Close) (1)      
  MONOSTABLE (2)      
  BISTABLE (3)      

4: Type of input no. 2

Type of input no. 2, what the input 2 will report if no contact is made

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 1
Options NO (Normal Open) (0)      
  NC (Normal Close) (1)      
  MONOSTABLE (2)      
  BISTABLE (3)      

5: Type of transmitted control frame for association group 1

Type of transmitted control frame for association group 1.

Overview

Activated via input IN1. The parameter allows to specify the type of alarm frame or to force transmission of control commands (BASIC_SET)

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 255
Options ALARM GENERIC (0)      
  ALARM SMOKE (1)      
  ALARM CO (2)      
  ALARM CO2 (3)      
  ALARM HEAT (4)      
  ALARM WATER (5)      
  BASIC_SET (255)      

6: Type of transmitted control frame for association group 2

Type of transmitted control frame for association group 2

Overview

Activated via input IN2. The parameter allows to specify the type of alarm frame or to force transmission of control commands (BASIC_SET)

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 255
Options ALARM GENERIC (0)      
  ALARM SMOKE (1)      
  ALARM CO (2)      
  ALARM CO2 (3)      
  ALARM HEAT (4)      
  ALARM WATER (5)      
  BASIC_SET (255)      

7: Forced Level of Dimming group 1

Value of the parameter specifying the forced levels.

Overview

Value of the parameter specifying the forced levels of dimming / opening sun blinds when comes ‘switch on’ / ‘open’ command to devices from association group no. 1.
In the case of alarm frames the alarm priority is specified.

Possible parameter settings: (1 – 99) and 255
Value of 255 makes it possible to activate the device when using
the Dimmer module it means activating the device and setting it to
the previous stored condition, e.g. when Dimmer is set to 30%, then
deactivated, and then reactivated using command 255, it will
automatically be set to the previous condition, i.e. 30%.

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 1 to 255
Default Value 255

8: Forced Level of Dimming group 2

Value of the parameter specifying forced levels.

Overview

Value of the parameter specifying the forced level of dimming /
opening sun blinds when comes “switch on” / ”open” command to
devices from association group no. 2.
In the case of alarm frames the alarm priority is specified.
Default value: 255
Possible parameter settings:
(1 – 99) and 255
Value of 255 makes it possible to activate the device; when using of
the Dimmer module it means activating the device and setting it to
the previous stored condition, e.g. when Dimmer is set to 30%, then
deactivated, and then reactivated using command 255, it will
automatically be set to the previous condition, i.e. 30%.

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 1 to 255
Default Value 255

9: Deactivate transmission of frame canceling alarm

Deactivating transmission of the frame cancelling the alarm

Overview

or the
control frame deactivating the device (Basic). It allows for disabling
the deactivation function or the alarm cancellation function for
devices associated with the appropriate input of the Fibaro Sensor.
Default value: 0, in the case of association group no. 1 and 2 the
information is sent
Possible parameter settings:
0 – in the case of association group no. 1 and 2 the information is
sent
1 – in the case of association group no. 1 the information is sent. In
the case of association group no. 2 the information is not sent.
2 – in the case of association group no. 1 the information is not
sent. In the case of association group no. 2 the information is sent.
NOTE: Information concerning alarm violation or activation
commands for devices from association groups are always
sent.

Property Value      
Configuration ID config_9_1      
Data Type INTEGER   Default Value 0
Options Groups 1 and 2 sent (0)      
  Group 1 sent, Group 2 not sent. (1)      
  Group 1 not sent, Group 2 sent. (2)      

10: Interval between successive readings of temperature sensors

Interval between successive readings of temperature

Overview

 from all sensors connected to the device in seconds. Note: taking temperature readings from the sensor does not result in sending a temperature condition report to the central hub.

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 1 to 255
Default Value 20

11: Interval betw. forcing to send report concerning the temp.

The forced report is sent immediately after

Overview

 the next reading of temperature from the sensor, irrespective of the settings
of parameter no. 12.
Default value: 200 s
Possible parameter settings:
0 – 255 s
0 – deactivating the function
Note: Frequent sending of temperature condition reports is
reasonable when the sensor is located somewhere where can
occure rapid changes of ambient temperature. In other cases
it is recommended to leave the parameter set to the default
value.

Property Value
Configuration ID config_11_1
Data Type INTEGER
Range 1 to 255
Default Value 200

12: Insensitiveness to temperature changes.

This is the maximum acceptable difference between

Overview

 the last reported temperature and the current temperature taken from the sensor. If the temperatures differ by the set value or more, then a report with the current temperature value is sent to the device

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 0 to 255
Default Value 8

13: Transmitting the alarm or control frame broadcast mode

Transmitting the alarm or control frame in ‘broadcast’ mode

Overview

 (i.e. to all devices within range), information sent in this mode is not repeated by the mesh network.
NOTE: If the broadcast mode of information transmission is activated for a given channel, then transmission of
information in “singlecast” mode to devices assigned to the
association group of this channel is deactivated.

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 0
Options IN1 and IN2 Broadcast inactive (0)      
  IN1 broadcast mode active, Sensor 2 broadcast mode inactive (1)      
  IN1 broadcast mode inactive, Sensor 2 broadcast mode active (2)      
  INI and IN2 broadcast mode active (3)      

14: Scene activation

Enable/Disable scene functionality.

Overview

The device offers the possibility of sending commands compatible with Command class scene activation. Information is sent to devices assigned to association group no. 3.

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 0
Options Scenes disabled (0)      
  Scenes enabled (1)      

1: Input 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Input 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Controller Updates

Reports on the condition of the device

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.