FGDW002 Fibaro Door Window Sensor 2

This describes the Z-Wave device FGDW002, manufactured by Fibargroup with the thing type UID of fibaro_fgdw002_00_000.

Fibaro Door Window Sensor 2

Wakeup Information

Available settings: 0 or 3600-64800 (in seconds (1-18h), 3600s (1h)
step)
Default setting: 21600 (6h)

The Door/Window Sensor will wake up after each defined time interval and always try to connect with the main controller. After a successful communication attempt, the sensor will update configuration parameters, associations and settings and will go into standby mode.

After failed communication attempt (e.g. lack of Z-Wave range) the device will go into standby mode and retry to establish connection with the main controller after the next time interval.

Setting wake up interval to 0 disables sending Wake Up Notification frame automatically.

Wake up may be still performed manually by a clicking one of the TMP buttons (while the other button is pressed).

Longer time interval means less frequent communication and thus a longer battery life.

Channels

The following table summarises the channels available for the FGDW002 Fibaro Door Window Sensor 2.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Tamper alarm alarm_tamper alarm_tamper   Switch
Door sensor sensor_door sensor_door Door Contact
Alarm (power) alarm_power alarm_power Door Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the FGDW002 Fibaro Door Window Sensor 2. Detailed information on each parameter can be found below.

Parameter Description
1: Door/window state What state is door/window when the magnet is close to the sensor
2: Visual LED indications - Open/close Visual LED indications - Open/close
2: Visual LED indications - wake up Visual LED indications - wake up
2: Visual LED indications - tampering Visual LED indications - tampering
3: Associations in Z-Wave network Security Mode Associations in Z-Wave network Security Mode
11: 2nd association group triggers 2nd association group triggers
12: Value of ON command frame sent to 2nd association group Value of ON command frame sent to 2nd association group
13: Value of OFF command frame sent to 2nd association group Value of OFF command frame sent to 2nd association group
14: Association for opening - time delay Association for opening - time delay
15: Association for closing - time delay Association for closing - time delay
30: Tamper - alarm cancellation delay Tamper - alarm cancellation delay
31: Tamper - reporting alarm cancellation Tamper - reporting alarm cancellation
50: Interval of temperature measurements Interval of temperature measurements
51: Temperature reports threshold Temperature reports threshold
52: Interval of temperature reports Interval of temperature reports
53: Temperature offset Temperature offset
54: Temperature alarm reports Temperature alarm reports
55: High temperature alarm threshold High temperature alarm threshold
56: Low temperature alarm threshold Low temperature alarm threshold
1: Lifeline reports the device status and allows for assigning single device only (main controller by …
2: On/Off is assigned to the device status - Hall effect sensor (sends Basic Set command frames)
3: Tamper is assigned to the TMP switch (sends alarm command frames)

1: Door/window state

What state is door/window when the magnet is close to the sensor

Overview

0 - closed when magnet near

1 - opened when magnet near

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options closed when magnet near (0)      
  opened when magnet near (1)      

2: Visual LED indications - Open/close

Visual LED indications - Open/close

Overview

Set or reset the indication of opening/closing status change (input IN) by the visual LED indicator.
Disabling events might extend battery life.

Property Value      
Configuration ID config_2_1_00000001      
Data Type INTEGER   Default Value 0
Options no indication (0)      
  open/close indication (1)      

2: Visual LED indications - wake up

Visual LED indications - wake up

Overview

Show indication of wake up events by the visual LED indicator.
Disabling events might extend battery life.

Property Value      
Configuration ID config_2_1_00000002      
Data Type INTEGER   Default Value 1
Options no indication (0)      
  Enable wake up notification (2)      

2: Visual LED indications - tampering

Visual LED indications - tampering

Overview

Enable or disable device tampering events indicated by the visual LED indicator.
Disabling events might extend battery life.

Property Value      
Configuration ID config_2_1_00000004      
Data Type INTEGER   Default Value 1
Options no indication (0)      
  Enable indication of device tampering (4)      

3: Associations in Z-Wave network Security Mode

Associations in Z-Wave network Security Mode

Overview

This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network Security Mode. It does not apply to 1st group “Lifeline”.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 3
Options none of the groups sent as secure (0)      
  2nd group "On/Off" sent as secure (1)      
  3rd group "Tamper" sent as secure (2)      
  2nd and 3rd group sent as secure (3)      

11: 2nd association group triggers

2nd association group triggers

Overview

Parameter defines events which result in sending on/off commands to devices added to the 2nd association group.

These commands are sent alternately to switch the devices on and off.

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 0
Options switch after opening and closing (0)      
  switch after opening (parameter 12) (1)      
  switch after closing (parameter 13) (2)      

12: Value of ON command frame sent to 2nd association group

Value of ON command frame sent to 2nd association group

Overview

Value sent to devices in 2nd association group when opening is detected The value of 0 turns OFF the device, 255 turns it ON. In case of associating devices allowing smooth control, values 1-99 allow to set an associated device to a specified level.

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 255
Default Value 255

13: Value of OFF command frame sent to 2nd association group

Value of OFF command frame sent to 2nd association group

Overview

Value sent to devices in 2nd association group when closing is detected The value of 0 turns OFF the device, 255 turns it ON. In case of associating devices allowing smooth control, values 1-99 allow to set an associated device to a specified level.

Property Value
Configuration ID config_13_2
Data Type INTEGER
Range 0 to 255
Default Value 255

14: Association for opening - time delay

Association for opening - time delay

Overview

Time that must elapse from opening to send the command frame to to devices in 2nd association group.

Property Value
Configuration ID config_14_2
Data Type INTEGER
Range 0 to 32400
Default Value 0

15: Association for closing - time delay

Association for closing - time delay

Overview

Time (in seconds) that must elapse from closing to send the command frame to devices in 2nd association group

Property Value
Configuration ID config_15_2
Data Type INTEGER
Range 0 to 32400
Default Value 0

30: Tamper - alarm cancellation delay

Tamper - alarm cancellation delay

Overview

Time period after which a tamper alarm will be cancelled.

Property Value
Configuration ID config_30_2
Data Type INTEGER
Range 0 to 32400
Default Value 5

31: Tamper - reporting alarm cancellation

Tamper - reporting alarm cancellation

Overview

Reporting cancellation of tamper alarm to the controller and 3rd association group.

Property Value      
Configuration ID config_31_1      
Data Type INTEGER   Default Value 0
Options do not send tamper cancellation report (0)      
  send tamper cancellation report (1)      

50: Interval of temperature measurements

Interval of temperature measurements

Overview

This parameter defines how often the temperature will be measured. The shorter the time, the more frequently the temperature will be measured, but the battery life will shorten.

Property Value
Configuration ID config_50_2
Data Type INTEGER
Range 0 to 32400
Default Value 300

51: Temperature reports threshold

Temperature reports threshold

Overview

This parameter defines the change of temperature in comparison with last reported, resulting in temperature report being sent to the main controller.

Available settings:

  • 0 - temperature reports based on threshold disabled
  • 1-300 - temperature threshold (0.1-30°C, 0.1°C step)
Property Value
Configuration ID config_51_2
Data Type INTEGER
Range 0 to 300
Default Value 10

52: Interval of temperature reports

Interval of temperature reports

Overview

This parameter determines how often the temperature reports will be sent to the main controller (regardless of parameters 50 and 51).

Available settings:

  • 0 - periodic temperature reports disabled
  • 300-32400 - time in seconds
Property Value
Configuration ID config_52_2
Data Type INTEGER
Range 0 to 32400
Default Value 0

53: Temperature offset

Temperature offset

Overview

The value to be added to the actual temperature, measured by the sensor (temperature compensation). Available settings: -1000–1000 (-100–100°C, 0.1°C step)

Property Value
Configuration ID config_53_2
Data Type INTEGER
Range -1000 to 1000
Default Value 0

54: Temperature alarm reports

Temperature alarm reports

Overview

Temperature alarms reported to the Z-Wave controller. Thresholds are set in parameters 55 and 56. Available settings: 0 - temperature alarms disabled 1 - high temperature alarm 2 - low temperature alarm 3 - high and low temperature alarms enabled

Property Value      
Configuration ID config_54_1      
Data Type INTEGER   Default Value 0
Options temperature alarms disabled (0)      
  high temperature alarm (1)      
  low temperature alarm (2)      
  high and low temperature alarms enabled (3)      

55: High temperature alarm threshold

High temperature alarm threshold

Overview

If temperature is higher than set value, overheat notification will be sent and high temperature alarm will be triggered (if activated).

Available settings:

  • 1-600 (0.1-60°C, 0.1°C step)
Property Value
Configuration ID config_55_2
Data Type INTEGER
Range 1 to 600
Default Value 350

56: Low temperature alarm threshold

Low temperature alarm threshold

Overview

If temperature is lower than the set value, underheat notification will be sent and low temperature alarm will be triggered (if activated). Available settings: 0-599 (0-59.9°C, 0.1°C step)

Property Value
Configuration ID config_56_2
Data Type INTEGER
Range 0 to 599
Default Value 100

1: Lifeline

reports the device status and allows for assigning single device only (main controller by default).

Overview

reports the device status and allows for assigning single device only (main controller by default).

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: On/Off

is assigned to the device status - Hall effect sensor (sends Basic Set command frames)

Overview

is assigned to the device status - Hall effect sensor (sends Basic Set command frames).

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Tamper

is assigned to the TMP switch (sends alarm command frames)

Overview

is assigned to the TMP switch (sends alarm command frames)

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.