FGFS101 Flood Sensor

This describes the Z-Wave device FGFS101, manufactured by Fibargroup with the thing type UID of fibaro_fgfs101_00_000.

Flood Sensor

Channels

The following table summarises the channels available for the FGFS101 Flood Sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
  battery-level system.battery-level    
Alarm (general) alarm_general alarm_general Door Switch
Alarm (water) sensor_flood sensor_flood   Switch
Binary Sensor 1 sensor_binary1 sensor_binary Door Switch
Sensor (temperature) 2 sensor_temperature2 sensor_temperature Temperature Number

Sensor (temperature) 2

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the FGFS101 Flood Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Alarm Cancellation Delay Time period (in seconds) that an alarm will still be indicated after the alarm condition h…
2: Acoustic and visual signals On / Off in case of flooding Parameter allows for LED indicator and acoustic alarm deactivation in case of flooding det…
5: Type of alarm frame sent to 1-st association group (FLOOD) Parameter determines a type of command frame sent by the Sensor in case flooding has been …
7: Forced Level of Dimming group 1 Value of the parameter specifying the forced level of dimming / opening sun blinds when co…
9: Alarm cancelling or turning a device off (Basic) command frame deactivation Set to 0 to disable all-clear basic set & alarm frame generation. After flooding, device w…
10: Interval between successive readings of temperature sensors Interval between successive readings of temperature in seconds.
12: Insensitiveness to temperature changes. Determines a minimum temperature change value (insensitivity level; def: 0,5C), resulting …
13: Alarm BROADCAST Transmit the alarm or control frame in ‘broadcast’ mode. Information sent in this mode is …
50: Low temperature alarm threshold The parameter stores a temperature value (def. 15C), below which LED indicator blinks with…
51: High temperature alarm threshold The parameter stores a temperature value (def. 35C), above which LED indicator blinks with…
61: Low temperature alarm indicator colour Default is blue (0x000000FF).
62: High temperature alarm indicator colour Default is red (0x00FF0000). 65535 * Red + 256 * Green + Blue
63: Managing a LED indicator under standard operation Parameter determines LED indicator’s operation. Set to 0 turns the indicator off, saving a…
73: Temperature measurement compensation Parameter stores a temperature value to be added to or deducted from the current temperatu…
74: Alarm frame sent to 2-nd Association Group activation (MOVEMENT_TAMPER / BUTTON_TAMPER) The device is able to turn on alarms resulting from se…
75: Visual and audible alarms duration Visual and audible alarm duration
76: Alarm frame / basic set frame retransmission time when flooding Parameter determines time period after which an alarm frame will be retransmitted. Value o…
77: Flood sensor functionality turned off Allows for turning of the internal flood sensor. Tamper and built in temperature sensor wi…
1: Flood Alarm  
2: Tilt & Tamper Sensors  
3: Device Status  

1: Alarm Cancellation Delay

Time period (in seconds) that an alarm will still be indicated after the alarm condition has ceased.

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 3600
Default Value 0

2: Acoustic and visual signals On / Off in case of flooding

Parameter allows for LED indicator and acoustic alarm deactivation in case of flooding detection

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 3
Options Acoustic and visual alarms inactive (0)      
  Acoustic alarm inactive, visual alarm active (1)      
  Acoustic alarm active, visual alarm inactive (2)      
  Acoustic and visual alarms active (3)      

5: Type of alarm frame sent to 1-st association group (FLOOD)

Parameter determines a type of command frame sent by the Sensor in case flooding has been detected or cancelled

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 255
Options ALARM WATER (0)      
  BASIC_SET (255)      

7: Forced Level of Dimming group 1

Value of the parameter specifying the forced level of dimming / opening sun blinds when comes ‘switch on’ / ‘open’ command to devices from association group no. 1.
In the case of alarm frames the alarm priority is specified. Possible parameter setti

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 1 to 255
Default Value 255

9: Alarm cancelling or turning a device off (Basic) command frame deactivation

Set to 0 to disable all-clear basic set & alarm frame generation. After flooding, device will keep reporting flooding even if flooding ceased.

Property Value      
Configuration ID config_9_1      
Data Type INTEGER   Default Value 1
Options Alarm (flooding) cancellation inactive (0)      
  Alarm (flooding) cancellation active (1)      

10: Interval between successive readings of temperature sensors

Interval between successive readings of temperature in seconds.

Property Value
Configuration ID config_10_2
Data Type INTEGER
Range 1 to 32767
Default Value 300

12: Insensitiveness to temperature changes.

Determines a minimum temperature change value (insensitivity level; def: 0,5C), resulting in a temperature report being sent to the main controller, according to the Parameter 10 settings

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 1000
Default Value 50

13: Alarm BROADCAST

Transmit the alarm or control frame in ‘broadcast’ mode. Information sent in this mode is not repeated by the mesh network.

Overview

NOTE: If the broadcast mode of information transmission is activated for a given alarm, then the information is not relayed through the mesh network.  It is only heard by directly reachable devices.

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 0
Options Broadcast inactive (0)      
  Flood broadcast mode active, Tamper broadcast mode inactive (1)      
  Flood broadcast mode inactive, Tamper broadcast mode active (2)      
  Flood and Tamper broadcast mode active (3)      

50: Low temperature alarm threshold

The parameter stores a temperature value (def. 15C), below which LED indicator blinks with a colour determined by a Parameter 61 settings. By default the LED indicator blinks blue.

Overview

Negative numbers are encoded in U2 (two’s compliment) standard.

-1 actual temperature = 65535 reported

-10000 = 55536

-32768 = 32768

32767 = 32767

Property Value
Configuration ID config_50_2
Data Type INTEGER
Range -10000 to 10000
Default Value 1500

51: High temperature alarm threshold

The parameter stores a temperature value (def. 35C), above which LED indicator blinks with a colour determined by the Parameter 62 settings. By default the LED indicator blinks red

Property Value
Configuration ID config_51_2
Data Type INTEGER
Range -10000 to 10000
Default Value 3500

61: Low temperature alarm indicator colour

Default is blue (0x000000FF).

Overview

NOTE: A main controller interprets colours as a sum of it component colours value. Each colours value is a number from 0 to 255. Eg: Indicated colour = 65536 * RED value + 256 * GREEN value + BLUE value

Property Value
Configuration ID config_61_4
Data Type INTEGER
Range 0 to 16777215
Default Value 255

62: High temperature alarm indicator colour

Default is red (0x00FF0000). 65535 * Red + 256 * Green + Blue

Overview

NOTE: A main controller interprets colours as a sum of it component colours value. Each colours value is a number from 0 to 255. Eg: Indicated colour = 65536 * RED value + 256 * GREEN value + BLUE value

Property Value
Configuration ID config_62_4
Data Type INTEGER
Range 0 to 16777215
Default Value 16711680

63: Managing a LED indicator under standard operation

Parameter determines LED indicator’s operation. Set to 0 turns the indicator off, saving a battery life

Property Value      
Configuration ID config_63_1      
Data Type INTEGER   Default Value 2
Options LED indicator doesn’t indicate the temperature (0)      
  LED indicator blinks temperature every measurement (1)      
  LED indicator indicates the temperature continuously (2)      

73: Temperature measurement compensation

Parameter stores a temperature value to be added to or deducted from the current temperature measured by internal temperature sensor in order to compensate the difference between air temperature and temperature at the floor level

Property Value
Configuration ID config_73_2
Data Type INTEGER
Range -10000 to 10000
Default Value 0

74: Alarm frame sent to 2-nd Association Group activation

(MOVEMENT_TAMPER / BUTTON_TAMPER) The device is able to turn on alarms resulting from sensor’s vibrations e.g. when the sensor is moved, or the TMP button released. 2-nd Association Group alarms are not cancelled.

Property Value      
Configuration ID config_74_1      
Data Type INTEGER   Default Value 2
Options Tamper alarms inactive (0)      
  Button tamper alarm active (1)      
  Movement tamper alarm active (2)      
  Button and movement tampers alarm active (3)      

75: Visual and audible alarms duration

Visual and audible alarm duration

Overview

User can silence the Flood Sensor. Because the Sensor’s alarm may last for a long time, it’s possible to turn off visual and audible alarm signaling to save battery. The parameter determines a time period after which alarm will become “quiet” - still active but the device will go into battery saving mode.  Visual or acoustic alarm will be reactivated after time period specified in parameter 76.  When alarm status ceases, alarm will be turned off immediately.

Value of 0 means visual and accoustic alarms are active indefinitely.  In battery power mode sensor will never go to sleep which may shorten battery life significantly.

Property Value
Configuration ID config_75_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

76: Alarm frame / basic set frame retransmission time when flooding

Parameter determines time period after which an alarm frame will be retransmitted. Value of 0 disables alarm frame retransmission.

Overview

NOTE: In case the time period set in this parameter is shorter than the one specified in parameter 75, the device will not quiet the alarm; it will remain active.

Property Value
Configuration ID config_76_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

77: Flood sensor functionality turned off

Allows for turning of the internal flood sensor. Tamper and built in temperature sensor will remain active

Property Value      
Configuration ID config_77_1      
Data Type INTEGER   Default Value 0
Options Default flood sensor operation (flood detection, reactions) (0)      
  Built in flood sensor TURNED OFF (1)      

1: Flood Alarm

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Tilt & Tamper Sensors

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Device Status

Property Value
Configuration ID group_3
Data Type TEXT
Range to