FGFS101 Flood Sensor

This describes the Z-Wave device FGFS101, manufactured by Fibargroup with the thing type UID of fibaro_fgfs101_23_023.

Flood Sensor

Channels

The following table summarises the channels available for the FGFS101 Flood Sensor.

Channel Channel Id Channel Type UID Category Item Type
  battery-level system.battery-level    
Alarm (flood) alarm_flood alarm_flood Door Switch
Binary Sensor (flood) sensor_binary1 sensor_binary Door Switch
Sensor (temperature) sensor_temperature2 sensor_temperature Temperature Number
Alarm (tamper) alarm_tamper2 alarm_tamper   Switch

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the FGFS101 Flood Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Alarm Cancellation Delay Additional delay after an alarm has ceased
2: Acoustic and visual signals On / Off in case of flooding LED indicator and acoustic alarm deactivation
5: Type of alarm frame sent to 1-st association group (FLOOD) Command frame sent by the Sensor in case flooding
7: Forced Level of Dimming group 1 Value of the parameter specifying linking to association group no. 1
9: Alarm cancelling or turning a device off Allows for deactivating device turn off and alarm cancellation functions
10: Interval between successive readings of temperature sensors Interval between successive readings of temperature in seconds.
12: Insensitiveness to temperature changes. Determines a minimum temperature change value (insensitivity level; def: 0,5C)
13: Alarm BROADCAST Transmitting the alarm or control frame in ‘broadcast’ mode
50: Low temperature alarm threshold The parameter stores a temperature value, below which LED indicator blinks.
51: High temperature alarm threshold The parameter stores a temperature value, above which LED indicator blinks.
61: Low temperature alarm indicator colour Default is blue (0x000000FF).
62: High temperature alarm indicator colour Default is red (0x00FF0000).
63: Managing a LED indicator under standard operation Parameter determines LED indicator’s operation
73: Temperature measurement compensation Parameter stores a offset value from the current temperature
74: Alarm frame sent to 2-nd Association Group activation sensor’s vibrations alarm
75: Visual and audible alarms duration Silence the Flood Sensor.
76: Visual and audible alarms duration Period after which an alarm frame will be retransmitted
77: Flood sensor functionality turned off Turning of the internal flood sensor.
1: Flood Alarm  
2: Tilt Sensor  
3: Device Status  

1: Alarm Cancellation Delay

Additional delay after an alarm has ceased

Overview

Additional delay after an alarm has ceased. The parameter allows you to specify additional time, after which the alarm is cancelled once its violation has ceased

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 3600
Default Value 0

2: Acoustic and visual signals On / Off in case of flooding

LED indicator and acoustic alarm deactivation

Overview

Parameter allows for LED indicator and acoustic alarm deactivation in case of flooding detection

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 3
Options Acoustic and visual alarms inactive (0)      
  Acoustic alarm inactive, visual alarm active (1)      
  Acoustic alarm active, visual alarm inactive (2)      
  Acoustic and visual alarms active (3)      

5: Type of alarm frame sent to 1-st association group (FLOOD)

Command frame sent by the Sensor in case flooding

Overview

Parameter determines a type of command frame sent by the Sensor in case flooding has been detected or cancelled

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 255
Options ALARM WATER (0)      
  BASIC_SET (255)      

7: Forced Level of Dimming group 1

Value of the parameter specifying linking to association group no. 1

Overview

Value of the parameter specifying the forced level of dimming / opening sun blinds when comes switch on / open command to devices from association group no. 1. In the case of alarm frames the alarm priority is specified. Possible parameter settings.

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 1 to 255
Default Value 255

9: Alarm cancelling or turning a device off

Allows for deactivating device turn off and alarm cancellation functions

Overview

Allows for deactivating device turn off and alarm cancellation functions for the devices assigned to 1-st association group

Property Value      
Configuration ID config_9_1      
Data Type INTEGER   Default Value 0
Options Alarm (flooding) cancellation inactive (0)      
  Alarm (flooding) cancellation active (1)      

10: Interval between successive readings of temperature sensors

Interval between successive readings of temperature in seconds.

Overview

Interval between successive readings of temperature from all sensors connected to the device in seconds.

Property Value
Configuration ID config_10_2
Data Type INTEGER
Range 1 to 32767
Default Value 300

12: Insensitiveness to temperature changes.

Determines a minimum temperature change value (insensitivity level; def: 0,5C)

Overview

Determines a minimum temperature change value (insensitivity level; def: 0,5C), resulting in a temperature report being sent to the main controller, according to the Parameter 10 settings

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 1000
Default Value 50

13: Alarm BROADCAST

Transmitting the alarm or control frame in ‘broadcast’ mode

Overview

Transmitting the alarm or control frame in ‘broadcast’ mode (i.e. to all devices within range), information sent in this mode is not repeated by the mesh network. NOTE: If the broadcast mode of information transmission is activated for a given 

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 0
Options Broadcast inactive (0)      
  Flood broadcast mode active, Tamper broadcast mode inactive (1)      
  Tamper broadcast mode inactive, Tamper broadcast mode active (2)      
  Flood and Tamper broadcast mode active (3)      

50: Low temperature alarm threshold

The parameter stores a temperature value, below which LED indicator blinks.

Overview

The parameter stores a temperature value (def. 15C), below which LED indicator blinks with a colour determined by a Parameter 61 settings. By default the LED indicator blinks blue. NOTE: The main controller does not interpret negative numbers 

Property Value
Configuration ID config_50_2
Data Type INTEGER
Range -10000 to 10000
Default Value 1500

51: High temperature alarm threshold

The parameter stores a temperature value, above which LED indicator blinks.

Property Value
Configuration ID config_51_2
Data Type INTEGER
Range -10000 to 10000
Default Value 3500

61: Low temperature alarm indicator colour

Default is blue (0x000000FF).

Overview

Default is blue (0x000000FF). NOTE: A main controller interprets colours as a sum of it component colours value. Each colours value is a number from 0 to 255. Eg: Indicated colour = 65536 * RED value + 256 * GREEN value + BLUE value

Property Value
Configuration ID config_61_4
Data Type INTEGER
Range 0 to 16777215
Default Value 255

62: High temperature alarm indicator colour

Default is red (0x00FF0000).

Overview

Default is red (0x00FF0000). NOTE: A main controller interprets colours as a sum of it component colours value. Each colours value is a number from 0 to 255. Eg: Indicated colour = 65536 * RED value + 256 * GREEN value + BLUE value

Property Value
Configuration ID config_62_4
Data Type INTEGER
Range 0 to 16777215
Default Value 16711680

63: Managing a LED indicator under standard operation

Parameter determines LED indicator’s operation

Overview

Parameter determines LED indicator’s operation. Set to 0 turns the indicator off, saving a battery life

Property Value      
Configuration ID config_63_1      
Data Type INTEGER   Default Value 2
Options LED indicator doesn’t indicate the temperature (0)      
  LED indicator indicates the temperature (blink) (1)      
  LED indicator indicates the temperature continuously (2)      

73: Temperature measurement compensation

Parameter stores a offset value from the current temperature

Overview

Parameter stores a temperature value to be added to or deducted from the current temperature measured by internal temperature sensor in order to compensate the difference between air temperature and temperature at the floor level

Property Value
Configuration ID config_73_2
Data Type INTEGER
Range -10000 to 10000
Default Value 0

74: Alarm frame sent to 2-nd Association Group activation

sensor’s vibrations alarm

Overview

(MOVEMENT_TAMPER / BUTTON_TAMPER) The device is able to turn on alarms resulting from sensor’s vibrations e.g. when the sensor is moved, or the TMP button released. 2-nd Association Group alarms are not cancelled.

Property Value      
Configuration ID config_74_1      
Data Type INTEGER   Default Value 2
Options Tamper alarms inactive (0)      
  Button tamper alarm active (1)      
  Movement tamper alarm active (2)      
  Button and movement tampers alarm active (3)      

75: Visual and audible alarms duration

Silence the Flood Sensor.

Overview

The user can silence the Flood Sensor. Because the Sensor’s alarm may last for a long time, it’s possible to turn off visual and audible alarm signaling to save battery. The parameter determines a time period after which alarm will become “quiet” - still 

Property Value
Configuration ID config_75_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

76: Visual and audible alarms duration

Period after which an alarm frame will be retransmitted

Overview

Parameter determines a time period after which an alarm frame will be retransmitted. The value of 0 cancels an alarm frame retransmission. The value of 65535 means ‘each 1 second’. NOTE: In case a time period set in this parameter is shorter th

Property Value
Configuration ID config_76_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

77: Flood sensor functionality turned off

Turning of the internal flood sensor.

Overview

Allows for turning of the internal flood sensor. Tamper and built in temperature sensor will remain active

Property Value      
Configuration ID config_77_1      
Data Type INTEGER   Default Value 0
Options Default flood sensor operation (flood detection, reactions) (0)      
  Built in flood sensor TURNED OFF (1)      

1: Flood Alarm

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Tilt Sensor

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Device Status

Property Value
Configuration ID group_3
Data Type TEXT
Range to