FGK101 Door Opening Sensor

This describes the Z-Wave device FGK101, manufactured by Fibargroup with the thing type UID of fibaro_fgk101_03_002.

Door Opening Sensor

Channels

The following table summarises the channels available for the FGK101 Door Opening Sensor.

Channel Channel Id Channel Type UID Category Item Type
Scene Number scene_number scene_number   Number
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (Temperature) sensor_temperature sensor_temperature Temperature Number
Door Sensor sensor_door sensor_door Door Contact
Tamper Alarm alarm_tamper alarm_tamper   Switch
  battery-level system.battery-level    
Alarm (general) alarm_general alarm_general Door Switch

Sensor (Temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the FGK101 Door Opening Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Operations mode Parameter defines device operation mode
2: Door/Window or alarm status Parameter defines state of the sensor when the magnet …
3: Visual LED indications This parameter defines events indicated by the visual …
4: Range test after double click Allows to enable activation of Z-Wave range test with …
10: 2nd association group triggers Parameter defines events which result in sending on/off …
11: Commands sent to 2nd association group Command frames sent to devices added to the 2nd association group.
12: Value of ON command frame sent to 2nd association group Value of ON command frame sent to 2nd association group
13: Value of OFF command frame sent to 2nd association group The value of 0 turns OFF the device, 255 turns it ON.
14: Time delay of ON command frame Time period after which ON command frame will be sent.
15: Time delay of OFF command frame Time period after which OFF command frame will be sent.
20: Type of sent alarm frames Type of control frames transmitted to the main controller …
30: Delay of tamper alarm cancellation Time period after which a tamper alarm will be cancelled.
31: Reporting tamper alarm cancellation Reporting cancellation of tamper alarm to the controller …
50: Interval of temperature measurements This parameter defines how often the temperature will …
51: Temperature reports threshold This parameter defines the change of temperature in …
52: Interval of temperature reports This parameter determines how often the temperature …
53: Temperature offset The value to be added to the actual temperature, measured …
54: Temperature alarm reports Temperature alarms reported to the Z-Wave controller.
55: High temperature alarm threshold If temperature is higher than set value, overheat …
56: Low temperature alarm threshold If temperature is lower than the set value, underheat …
70: Scene activation functionality The device can trigger scenes using scene IDs assigned …
71: Alarm broadcast Settings for broadcasting ON/OFF commands, sensor …
72: Associations in Z-Wave network Security Mode This parameter defines how commands are sent in …
1: Lifeline  
2: Control  
3: Alarm  
4: Sensor ZW3  
5: Tamper ZW3  

1: Operations mode

Parameter defines device operation mode

Overview

Available settings:

0 - Door/Window Sensor or external alarm sensor
1 - external button

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 1
Default Value 0

2: Door/Window or alarm status

Parameter defines state of the sensor when the magnet …

Overview

… is close. If the alarm sensor is connected, it determines the output type. Parameter inactive in external button mode (parameter 1 set to 1).

Available settings:

0 - Door/Window Sensor or external alarm sensor
1 - external button

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 1
Default Value 0

3: Visual LED indications

This parameter defines events indicated by the visual …

Overview

… LED indicator. Disabling events might extend battery life.

Available settings:

0 - no indications
1 - indication of opening/closing status change
(input IN)
2 - indication of wake up (1 x click or periodical)
4 - indication of device tampering

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 6
Default Value 6

4: Range test after double click

Allows to enable activation of Z-Wave range test with …

Overview

… double click of a TMP button.

Available settings:

0 - disabled
1 - enabled

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 1
Default Value 0

10: 2nd association group triggers

Parameter defines events which result in sending on/off …

Overview

… commands to devices added to the 2nd association group. These commands are sent alternately to switch the devices on and off. Commands represent the values of BASIC SET command frames. Parameter is inactive in external button mode (parameter 1 set to 1).

Available settings:

0 - switch after opening and closing
1 - switch after opening
2 - switch after closing

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 2
Default Value 0

11: Commands sent to 2nd association group

Command frames sent to devices added to the 2nd association group.

Overview

Available settings:

0 - ON
1 - OFF
2 - ON & OFF

Property Value
Configuration ID config_11_1
Data Type INTEGER
Range 0 to 2
Default Value 2

12: Value of ON command frame sent to 2nd association group

Value of ON command frame sent to 2nd association group

Overview

The value of 0 turns OFF the device, 255 turns it On. In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set
an associated device to a specifed level.

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 255
Default Value 255

13: Value of OFF command frame sent to 2nd association group

The value of 0 turns OFF the device, 255 turns it ON.

Overview

In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an associated device to a specified level

The value of 0 turns OFF the device, 255 turns it On. In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set
an associated device to a specifed level.

Property Value
Configuration ID config_13_2
Data Type INTEGER
Range 0 to 255
Default Value 0

14: Time delay of ON command frame

Time period after which ON command frame will be sent.

Property Value
Configuration ID config_14_2
Data Type INTEGER
Range 0 to 32400
Default Value 0

15: Time delay of OFF command frame

Time period after which OFF command frame will be sent.

Property Value
Configuration ID config_15_2
Data Type INTEGER
Range 0 to 32400
Default Value 0

20: Type of sent alarm frames

Type of control frames transmitted to the main controller …

Overview

… and 3rd association group “Alarm”. If an external sensor is connected to IN input, it is possible to choose its functionality. Otherwise it is recommended to set this parameter to default value.

Available settings:

0 - Door/Window Sensor (General Purpose Alarm)
1 - smoke sensor (Smoke Alarm)
2 - CO detector (CO Alarm)
3 - CO2 detector (CO2 Alarm)
4 - high temperature sensor (Heat Alarm)
5 - flood sensor (Water Alarm)

Property Value
Configuration ID config_20_1
Data Type INTEGER
Range 0 to 5
Default Value 0

30: Delay of tamper alarm cancellation

Time period after which a tamper alarm will be cancelled.

Property Value
Configuration ID config_30_2
Data Type INTEGER
Range 0 to 32400
Default Value 5

31: Reporting tamper alarm cancellation

Reporting cancellation of tamper alarm to the controller …

Overview

… and 5th association group.

Available settings:

0 - do not send tamper cancellation report
1 - send tamper cancellation report

Property Value
Configuration ID config_31_1
Data Type INTEGER
Range 0 to 1
Default Value 1

50: Interval of temperature measurements

This parameter defines how often the temperature will …

Overview

… be measured. The shorter the time, the more frequently the temperature will be measured, but the battery life will shorten.

Available settings:

0 - temperature measurements disabled
5-32400 - time in seconds

Property Value
Configuration ID config_50_2
Data Type INTEGER
Range 0 to 32400
Default Value 300

51: Temperature reports threshold

This parameter defines the change of temperature in …

Overview

…comparison with last reported, resulting in temperature report being sent to the main controller.

Available settings:

0 - temperature reports based on threshold disabled
1-300 - temperature threshold (0.1-30°C, 0.1°C step)

Property Value
Configuration ID config_51_2
Data Type INTEGER
Range 0 to 300
Default Value 10

52: Interval of temperature reports

This parameter determines how often the temperature …

Overview

…  reports will be sent to the main controller.

Available settings:

0 - periodic temperature reports disabled
5-32400 - time in seconds

Property Value
Configuration ID config_52_2
Data Type INTEGER
Range 0 to 32400
Default Value 0

53: Temperature offset

The value to be added to the actual temperature, measured …

Overview

… by the sensor (temperature compensation).

Available settings:

-1000-1000 (-100-100°C, 0.1°C step)

Property Value
Configuration ID config_53_4
Data Type INTEGER
Range -1000 to 1000
Default Value 0

54: Temperature alarm reports

Temperature alarms reported to the Z-Wave controller.

Overview

Thresholds are set in parameters 55 and 56.

Available settings:

0 - temperature alarms disabled
1 - high temperature alarm
2 - low temperature alarm
3 - high and low temperature alarms enabled

Property Value
Configuration ID config_54_1
Data Type INTEGER
Range 0 to 3
Default Value 0

55: High temperature alarm threshold

If temperature is higher than set value, overheat …

Overview

… notification will be sent and high temperature scene will be triggered (if activated).

Available settings:

0-1000 (0-100°C, 0.1°C step)

Property Value
Configuration ID config_55_2
Data Type INTEGER
Range 0 to 1000
Default Value 540

56: Low temperature alarm threshold

If temperature is lower than the set value, underheat …

Overview

… notification will be sent and low temperature scene will be triggered (if activated).

Available settings:

-300-700 (-30-70°C, 0.1°C step)

Property Value
Configuration ID config_56_2
Data Type INTEGER
Range -300 to 700
Default Value 40

70: Scene activation functionality

The device can trigger scenes using scene IDs assigned …

Overview

… to different events. To deactivate all scenes set the value to 0. To activate all scenes set the value to 3903.

Available settings:

1 - [ID 10] opening door/window (single click)
2 - [ID 11] closing door/window (single click)
4 - [ID 12] holding
8 - [ID 13] releasing
16 - [ID 14] double click
32 - [ID 15] triple click
256 - [ID 50] high temperature - door/window
opened
512 - [ID 50] high temperature - door/window
closed
1024 - [ID 51] low temperature - door/window
opened
2048 - [ID 51] low temperature - door/window
closed

Property Value
Configuration ID config_70_2
Data Type INTEGER
Range 0 to 2048
Default Value 0

71: Alarm broadcast

Settings for broadcasting ON/OFF commands, sensor …

Overview

… alarm and tamper alarm. Value other than 0 means alarms are sent in Broadcast Mode, to all devices only within the range of the device. They are not repeated by the mesh network.

Available settings:

0 - broadcasts inactive
1 - ON/OFF commands broadcast active
2 - sensor alarm broadcast active
4 - tamper alarm broadcast active

Property Value
Configuration ID config_71_1
Data Type INTEGER
Range 0 to 4
Default Value 0

72: Associations in Z-Wave network Security Mode

This parameter defines how commands are sent in …

Overview

… specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st group “Lifeline”.

Available settings:

0 - none of the groups sent as secure
1 - 2nd group ”Control” sent as secure
2 - 3rd group ”Alarm” sent as secure
4 - 4th group “Sensor ZW3” sent as secure
8 - 5th group “Tamper ZW3” sent as secure

15 - (all)

Property Value
Configuration ID config_72_1
Data Type INTEGER
Range 0 to 15
Default Value 15

1: Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Control

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Alarm

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Sensor ZW3

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Tamper ZW3

Property Value
Configuration ID group_5
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.