FGKF601 Keyfob

This describes the Z-Wave device FGKF601, manufactured by Fibargroup with the thing type UID of fibaro_fgkf601_00_000.

Keyfob

Channels

The following table summarises the channels available for the FGKF601 Keyfob.

Channel Channel Id Channel Type UID Category Item Type
Scene Number scene_number scene_number   Number
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the FGKF601 Keyfob. Detailed information on each parameter can be found below.

Parameter Description
1: Lock Mode - unlocking sequence 0 - Lock Mode disabled, 9-28086 - unlocking sequence
2: Lock Mode - time to lock and locking button 0 - Lock Mode disabled, 5-1791 - calculated value
3: First scene sequence 0 - 1st sequence disabled, 9-28086 - value of sequence
4: Second scene sequence 0 - 2nd sequence disabled, 9-28086 - value of sequence
5: Third scene sequence 0 - 3rd sequence disabled, 9-28086 - value of sequence
6: Fourth scene sequence 0 - 4th sequence disabled, 9-28086 - value of sequence
7: Fifth scene sequence 0 - 5th sequence disabled, 9-28086 - value of sequence
8: Sixth scene sequence 0 - 6th sequence disabled, 9-28086 - value of sequence
9: Sequences - timeout 5-30 (0.5-3s, 0.1s step) - time to lock
10: Single button associations - operating mode  
11: Value sent to □ association group 1-99 or 255 (last state)
12: Value sent to ○ association group 1-99 or 255 (last state)
13: Value sent to x association group 1-99 or 255 (last state)
14: Value sent to Δ association group 1-99 or 255 (last state)
15: Value sent to - association group 1-99 or 255 (last state)
16: Value sent to + association group 1-99 or 255 (last state)
17: Paired buttons association for □ and ○  
18: Paired buttons association for x and Δ  
19: Paired buttons association for - and +  
21: Scene activation for □ button 1 = 1 time, 2 = 2 times, 4 = 3 times, 8 = held down and released
22: Scene activation for ○ button 1 = 1 time, 2 = 2 times, 4 = 3 times, 8 = held down and released
23: Scene activation for x button 1 = 1 time, 2 = 2 times, 4 = 3 times, 8 = held down and released
24: Scene activation for Δ button 1 = 1 time, 2 = 2 times, 4 = 3 times, 8 = held down and released
25: Scene activation for - button 1 = 1 time, 2 = 2 times, 4 = 3 times, 8 = held down and released
26: Scene activation for + button 1 = 1 time, 2 = 2 times, 4 = 3 times, 8 = held down and released
29: Associations in Z-Wave network security mode  
1: Lifeline “Lifeline” reports the device status and allows for assigning single device only (main con…
2: Square - On/Off “Square - On/Off” is assigned to clicking the □ button and is used to turn on/off associat…
3: Square - Multilevel “Square - Multilevel” is assigned to clicking and holding the □ button and is used to turn…
4: Circle - On/Off “Circle - On/Off” is assigned to clicking the ○ button and is used to turn on/off associat…
5: Circle - Multilevel “Circle - Multilevel” is assigned to clicking and holding the ○ button and is used to turn…
6: Cross - On/Off “Cross - On/Off” is assigned to clicking the x button and is used to turn on/off associate…
7: Cross - Multilevel “Cross - Multilevel” is assigned to clicking and holding the x button and is used to turn …
8: Triangle - On/Off “Triangle - On/Off” is assigned to clicking the Δ button and is used to turn on/off associ…
9: Triangle - Multilevel “Triangle - Multilevel” is assigned to clicking and holding the Δ button and is used to tu…
10: Minus - On/Off “Minus - On/Off” is assigned to clicking the - button and is used to turn on/off associate…
11: Minus - Multilevel “Minus - Multilevel” is assigned to clicking and holding the - button and is used to turn …
12: Plus - On/Off “Plus - On/Off” is assigned to clicking the + button and is used to turn on/off associated…
13: Plus - Multilevel “Plus - Multilevel” is assigned to clicking and holding the + button and is used to turn o…

1: Lock Mode - unlocking sequence

0 - Lock Mode disabled, 9-28086 - unlocking sequence

Overview

This parameter allows to activate Lock Mode and set up unlocking sequence. Device will lock after time set in parameter 2 or after pressing and holding selected button. 

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 28086
Default Value 0

2: Lock Mode - time to lock and locking button

0 - Lock Mode disabled, 5-1791 - calculated value

Overview

This parameter allows to set time that must elapse from the last press of the button to lock the device and locking button.

Setting locking button will deactivate associations and scenes for pressing and holding the selected button.

This parameter is irrelevant if parameter 1 is set to 0 (Lock Mode disable).

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 1791
Default Value 60

3: First scene sequence

0 - 1st sequence disabled, 9-28086 - value of sequence

Overview

This parameter allows to set up sequence that activates scene with ID 7. See “Sequences” on page 10 for more information.

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 0 to 28086
Default Value 0

4: Second scene sequence

0 - 2nd sequence disabled, 9-28086 - value of sequence

Overview

This parameter allows to set up sequence that activates scene with ID 8.

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 0 to 28086
Default Value 0

5: Third scene sequence

0 - 3rd sequence disabled, 9-28086 - value of sequence

Overview

This parameter allows to set up sequence that activates scene with ID 9.

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 0 to 28086
Default Value 0

6: Fourth scene sequence

0 - 4th sequence disabled, 9-28086 - value of sequence

Overview

This parameter allows to set up sequence that activates scene with ID 10. 

Property Value
Configuration ID config_6_2
Data Type INTEGER
Range 0 to 28086
Default Value 0

7: Fifth scene sequence

0 - 5th sequence disabled, 9-28086 - value of sequence

Overview

This parameter allows to set up sequence that activates scene with ID 11. 

Property Value
Configuration ID config_7_2
Data Type INTEGER
Range 0 to 28086
Default Value 0

8: Sixth scene sequence

0 - 6th sequence disabled, 9-28086 - value of sequence

Overview

This parameter allows to set up sequence that activates scene with ID 12.

Property Value
Configuration ID config_8_2
Data Type INTEGER
Range 0 to 28086
Default Value 0

9: Sequences - timeout

5-30 (0.5-3s, 0.1s step) - time to lock

Overview

This parameter allows to set time that must elapse from the last click of the button to check if the sequence is valid.

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 5 to 30
Default Value 10

10: Single button associations - operating mode

Overview

This parameter allows to choose operating mode for single button associations. 

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 0
Options single click switches state to opposite (0)      
  single click => opposite, double click => max (1)      
  single click turns on, double click turns off (2)      

11: Value sent to □ association group

1-99 or 255 (last state)

Overview

This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices.

1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them on

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 1 to 255
Default Value 255

12: Value sent to ○ association group

1-99 or 255 (last state)

Overview

This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices.

1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them on

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 1 to 255
Default Value 255

13: Value sent to x association group

1-99 or 255 (last state)

Overview

This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices.

1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them on

Property Value
Configuration ID config_13_2
Data Type INTEGER
Range 1 to 255
Default Value 255

14: Value sent to Δ association group

1-99 or 255 (last state)

Overview

This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices.

1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them on

Property Value
Configuration ID config_14_2
Data Type INTEGER
Range 1 to 255
Default Value 255

15: Value sent to - association group

1-99 or 255 (last state)

Overview

This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices.

1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them on

Property Value
Configuration ID config_15_2
Data Type INTEGER
Range 1 to 255
Default Value 255

16: Value sent to + association group

1-99 or 255 (last state)

Overview

This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices.

1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them on

Property Value
Configuration ID config_16_2
Data Type INTEGER
Range 1 to 255
Default Value 255

17: Paired buttons association for □ and ○

Overview

This parameter allows to activate paired buttons association mode for □ and ○ buttons. Paired buttons are dependent and association are sent only to □ groups. ○ turns devices on and increases value, □ turns them off and decreases value.

Property Value      
Configuration ID config_17_1      
Data Type INTEGER   Default Value 0
Options paired buttons association inactive (0)      
  paired buttons association active (1)      

18: Paired buttons association for x and Δ

Overview

This parameter allows to activate paired buttons association mode for x and Δ buttons. Paired buttons are dependent and association are sent only to x groups. Δ turns devices on and increases value, x turns them off and decreases value.

Property Value      
Configuration ID config_18_1      
Data Type INTEGER   Default Value 0
Options paired buttons association inactive (0)      
  paired buttons association active (1)      

19: Paired buttons association for - and +

Overview

This parameter allows to activate paired buttons association mode for - and + buttons. Paired buttons are dependent and association are sent only to - groups. + turns devices on and increases value, - turns them off and decreases value. 

Property Value      
Configuration ID config_19_1      
Data Type INTEGER   Default Value 0
Options paired buttons association inactive (0)      
  paired buttons association active (1)      

21: Scene activation for □ button

1 = 1 time, 2 = 2 times, 4 = 3 times, 8 = held down and released

Overview

This parameter determines which actions result in sending assigned scene IDs and attributes to the controller.

1 - Key pressed 1 time
2 - Key pressed 2 times
4 - Key pressed 3 times
8 - Key held down & released

Combine multiple actions by or’ing the values.

Property Value
Configuration ID config_21_1
Data Type INTEGER
Range 0 to 15
Default Value 9

22: Scene activation for ○ button

1 = 1 time, 2 = 2 times, 4 = 3 times, 8 = held down and released

Overview

This parameter determines which actions result in sending assigned scene IDs and attributes to the controller.

1 - Key pressed 1 time
2 - Key pressed 2 times
4 - Key pressed 3 times
8 - Key held down & released

Combine multiple actions by or’ing the values.

Property Value
Configuration ID config_22_1
Data Type INTEGER
Range 0 to 15
Default Value 9

23: Scene activation for x button

1 = 1 time, 2 = 2 times, 4 = 3 times, 8 = held down and released

Overview

This parameter determines which actions result in sending assigned scene IDs and attributes to the controller.

1 - Key pressed 1 time
2 - Key pressed 2 times
4 - Key pressed 3 times
8 - Key held down & released

Combine multiple actions by or’ing the values.

Property Value
Configuration ID config_23_1
Data Type INTEGER
Range 0 to 15
Default Value 9

24: Scene activation for Δ button

1 = 1 time, 2 = 2 times, 4 = 3 times, 8 = held down and released

Overview

This parameter determines which actions result in sending assigned scene IDs and attributes to the controller.

1 - Key pressed 1 time
2 - Key pressed 2 times
4 - Key pressed 3 times
8 - Key held down & released

Combine multiple actions by or’ing the values.

Property Value
Configuration ID config_24_1
Data Type INTEGER
Range 0 to 15
Default Value 9

25: Scene activation for - button

1 = 1 time, 2 = 2 times, 4 = 3 times, 8 = held down and released

Overview

This parameter determines which actions result in sending assigned scene IDs and attributes to the controller.

1 - Key pressed 1 time
2 - Key pressed 2 times
4 - Key pressed 3 times
8 - Key held down & released

Combine multiple actions by or’ing the values.

Property Value
Configuration ID config_25_1
Data Type INTEGER
Range 0 to 15
Default Value 9

26: Scene activation for + button

1 = 1 time, 2 = 2 times, 4 = 3 times, 8 = held down and released

Overview

This parameter determines which actions result in sending assigned scene IDs and attributes to the controller.

1 - Key pressed 1 time
2 - Key pressed 2 times
4 - Key pressed 3 times
8 - Key held down & released

Combine multiple actions by or’ing the values.

Property Value
Configuration ID config_26_1
Data Type INTEGER
Range 0 to 15
Default Value 9

29: Associations in Z-Wave network security mode

Overview

Parameter defines how commands are sent in specified association groups: using Security Mode or not. Parameter is active only in Z-Wave network Security Mode. It does not apply to 1st “Lifeline” association group.

Available settings:

1 - 2nd group sent using Security Mode
2 - 3rd group sent using Security Mode
4 - 4th group sent using Security Mode
8 - 5th group sent using Security Mode
16 - 6th group sent using Security Mode
32 - 7th group sent using Security Mode
64 - 8th group sent using Security Mode
128 - 9th group sent using Security Mode
256 - 10th group sent using Security Mode
512 - 11th group sent using Security Mode
1024 - 12th group sent using Security Mode
2048 - 13th group sent using Security Mode

Set multiple values by or’ing the values together.

Property Value
Configuration ID config_29_2
Data Type INTEGER
Range 0 to 4095
Default Value 4095

1: Lifeline

“Lifeline” reports the device status and allows for assigning single device only (main controller by default).

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Square - On/Off

“Square - On/Off” is assigned to clicking the □ button and is used to turn on/off associated devices.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Square - Multilevel

“Square - Multilevel” is assigned to clicking and holding the □ button and is used to turn on/off and change level of associated devices.

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Circle - On/Off

“Circle - On/Off” is assigned to clicking the ○ button and is used to turn on/off associated devices.

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Circle - Multilevel

“Circle - Multilevel” is assigned to clicking and holding the ○ button and is used to turn on/off and change level of associated devices.

Property Value
Configuration ID group_5
Data Type TEXT
Range to

6: Cross - On/Off

“Cross - On/Off” is assigned to clicking the x button and is used to turn on/off associated devices.

Property Value
Configuration ID group_6
Data Type TEXT
Range to

7: Cross - Multilevel

“Cross - Multilevel” is assigned to clicking and holding the x button and is used to turn on/off and change level of associated devices.

Property Value
Configuration ID group_7
Data Type TEXT
Range to

8: Triangle - On/Off

“Triangle - On/Off” is assigned to clicking the Δ button and is used to turn on/off associated devices.

Property Value
Configuration ID group_8
Data Type TEXT
Range to

9: Triangle - Multilevel

“Triangle - Multilevel” is assigned to clicking and holding the Δ button and is used to turn on/off and change level of associated devices.

Property Value
Configuration ID group_9
Data Type TEXT
Range to

10: Minus - On/Off

“Minus - On/Off” is assigned to clicking the - button and is used to turn on/off associated devices.

Property Value
Configuration ID group_10
Data Type TEXT
Range to

11: Minus - Multilevel

“Minus - Multilevel” is assigned to clicking and holding the - button and is used to turn on/off and change level of associated devices.

Property Value
Configuration ID group_11
Data Type TEXT
Range to

12: Plus - On/Off

“Plus - On/Off” is assigned to clicking the + button and is used to turn on/off associated devices.

Property Value
Configuration ID group_12
Data Type TEXT
Range to

13: Plus - Multilevel

“Plus - Multilevel” is assigned to clicking and holding the + button and is used to turn on/off and change level of associated devices.

Property Value
Configuration ID group_13
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.