FGPB101 A real push button (switch) available in several colors.

This describes the Z-Wave device FGPB101, manufactured by Fibargroup with the thing type UID of fibaro_fgpb101_00_000.

A real push button (switch) available in several colors.

Channels

The following table summarises the channels available for the FGPB101 A real push button (switch) available in several colors..

Channel Channel Id Channel Type UID Category Item Type
Scene Number scene_number scene_number   Number
Alarm alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the FGPB101 A real push button (switch) available in several colors.. Detailed information on each parameter can be found below.

Parameter Description
1: Scenes sent to the controller This parameter determines which actions result in sending scene IDs to them.
3: Associations in Z-Wave network Security Mode This parameter defines how commands are sent in specified association groups
10: Key Pressed 1 time – command sent to 2nd group Associated in 2nd association group after a single click.
11: Key Pressed 1 time – value of SWITCH ON sent to 2nd group Value of SWITCH ON command sent to devices in 2nd association group
12: Key Pressed 2 times – command sent to 2nd group Commands sent to devices associated in 2nd association group
13: Key Pressed 2 times – value of SWITCH ON sent to 2nd group SWITCH ON command in 2nd association group after double click
14: Key Pressed 3 times – command sent to 2nd group Commands associated in 2nd association group after a triple click.
15: Key Pressed 3 times – value of SWITCH ON sent to 2nd group Value of SWITCH ON command sent in 2nd association group after a triple click
20: Key Pressed 1 time – command sent to 3rd group Ssent to devices associated in 3rd association group after a single click.
21: Key Pressed 1 time – value of SWITCH ON sent to 3rd group Value of SWITCH ON command sent in 3rd association group after a single click.
22: Key Pressed 2 times – command sent to 3rd group Sent to associated in 3rd association group after a double click.
23: Key Pressed 2 times – value of SWITCH ON sent to 3rd group Value of SWITCH ON command sent in 3rd association group after a double click.
24: Key Pressed 3 times – command sent to 3rd group Sent to devices associated in 3rd association group after a triple click.
25: Key Pressed 3 times – value of SWITCH ON sent to 3rd group Value SWITCH ON command sent in 3rd association group after a triple click.
29: Key Held Down – command sent to 3rd group Sent associated in 3rd association group after holding the button down.
30: Alarm frame triggers Which actions result in sending alarm frames to 4th association group.
1: Lifeline reports the device status and allows for assigning single device only (main controller by …
2: On/Off assigned to clicking the button and is used to turn on/off associated devices
3: Dimmer is assigned to holding the button and is used to change level of associated devices
4: Alarm assigned to clicking and/or holding the button (triggers are defined in parameter 30) and …

1: Scenes sent to the controller

This parameter determines which actions result in sending scene IDs to them.

Overview

This parameter determines which actions result in sending scene IDs and attributes assigned to them.

Available settings:

1 - Key Pressed 1 time
2 - Key Pressed 2 times 
4 - Key Pressed 3 times
8 - Key Pressed 4 times
16 - Key Pressed 5 times
32 - Key Held Down
64 - Key Released

Values of parameter 1 may be combined, e.g. 1+2=3 means that scenes will be sent after pressing the button once or twice.

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 1 to 127
Default Value 127

3: Associations in Z-Wave network Security Mode

This parameter defines how commands are sent in specified association groups

Overview

This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network Security Mode. It does not apply to 1st „Lifeline” group.

1 - 2nd group sent as secure
2 - 3rd group sent as secure
4 - 4th group sent as secure

Values of parameter 3 may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 1 to 7
Default Value 7

10: Key Pressed 1 time – command sent to 2nd group

Associated in 2nd association group after a single click.

Overview

This parameter defines commands sent to devices associated in 2nd association group after a single click.

Available settings:

0 - no action
1 - SWITCH ON
2 - SWITCH OFF
3 - SWITCH ON/OFF – alternately

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 3
Default Value 3

11: Key Pressed 1 time – value of SWITCH ON sent to 2nd group

Value of SWITCH ON command sent to devices in 2nd association group

Overview

This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a single click.

Available settings:

1-255 - sent value

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 1 to 255
Default Value 255

12: Key Pressed 2 times – command sent to 2nd group

Commands sent to devices associated in 2nd association group

Overview

This parameter defines commands sent to devices associated in 2nd association group after a double click.

Available settings:

0 - no action
1 - SWITCH ON
2 - SWITCH OFF
3 - SWITCH ON/OFF – alternately

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 0 to 3
Default Value 1

13: Key Pressed 2 times – value of SWITCH ON sent to 2nd group

SWITCH ON command in 2nd association group after double click

Overview

This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a double click.

Available settings:

1-255 - sent value

Property Value
Configuration ID config_13_2
Data Type INTEGER
Range 1 to 255
Default Value 99

14: Key Pressed 3 times – command sent to 2nd group

Commands associated in 2nd association group after a triple click.

Overview

This parameter defines commands sent to devices associated in 2nd association group after a triple click.

Available settings:

0 - no action
1 - SWITCH ON
2 - SWITCH OFF
3 - SWITCH ON/OFF – alternately

Property Value
Configuration ID config_14_1
Data Type INTEGER
Range 0 to 3
Default Value 0

15: Key Pressed 3 times – value of SWITCH ON sent to 2nd group

Value of SWITCH ON command sent in 2nd association group after a triple click

Overview

This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a triple click.

Available settings:

1-255 - sent value

Property Value
Configuration ID config_15_2
Data Type INTEGER
Range 1 to 255
Default Value 255

20: Key Pressed 1 time – command sent to 3rd group

Ssent to devices associated in 3rd association group after a single click.

Overview

This parameter defines commands sent to devices associated in 3rd association group after a single click.

Available settings:

0 - no action
1 - SWITCH ON
2 - SWITCH OFF
3 - SWITCH ON/OFF – alternately

Property Value
Configuration ID config_20_1
Data Type INTEGER
Range 0 to 3
Default Value 3

21: Key Pressed 1 time – value of SWITCH ON sent to 3rd group

Value of SWITCH ON command sent in 3rd association group after a single click.

Overview

This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a single click.

Available settings:

1-255 - sent value

Property Value
Configuration ID config_21_2
Data Type INTEGER
Range 1 to 255
Default Value 255

22: Key Pressed 2 times – command sent to 3rd group

Sent to associated in 3rd association group after a double click.

Overview

This parameter defines commands sent to devices associated in 3rd association group after a double click.

Available settings:

0 - no action
1 - SWITCH ON
2 - SWITCH OFF
3 - SWITCH ON/OFF – alternately

Property Value
Configuration ID config_22_1
Data Type INTEGER
Range 0 to 3
Default Value 1

23: Key Pressed 2 times – value of SWITCH ON sent to 3rd group

Value of SWITCH ON command sent in 3rd association group after a double click.

Overview

This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a double click.

Available settings:

1-255 - sent value

Property Value
Configuration ID config_23_2
Data Type INTEGER
Range 1 to 255
Default Value 99

24: Key Pressed 3 times – command sent to 3rd group

Sent to devices associated in 3rd association group after a triple click.

Overview

This parameter defines commands sent to devices associated in 3rd association group after a triple click.

Available settings:

0 - no action
1 - SWITCH ON
2 - SWITCH OFF
3 - SWITCH ON/OFF – alternately

Property Value
Configuration ID config_24_1
Data Type INTEGER
Range 0 to 3
Default Value 0

25: Key Pressed 3 times – value of SWITCH ON sent to 3rd group

Value SWITCH ON command sent in 3rd association group after a triple click.

Overview

This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a triple click.

Available settings:

1-255 - sent value

Property Value
Configuration ID config_25_2
Data Type INTEGER
Range 1 to 255
Default Value 255

29: Key Held Down – command sent to 3rd group

Sent associated in 3rd association group after holding the button down.

Overview

This parameter defines commands sent to devices associated in 3rd association group after holding the button down.

Available settings:

0 - no action
1 - START LEVEL CHANGE UP (brightening)
2 - START LEVEL CHANGE DOWN (dimming)
3 - START LEVEL CHANGE UP/DOWN (brightening/dimming) – alternately

Property Value
Configuration ID config_29_1
Data Type INTEGER
Range 0 to 3
Default Value 3

30: Alarm frame triggers

Which actions result in sending alarm frames to 4th association group.

Overview

Parameter determines which actions result in sending alarm frames to 4th association group.

Available settings:

1 - Key Pressed 1 time
2 - Key Pressed 2 times
4 - Key Pressed 3 times
8 - Key Pressed 4 times
16 - Key Pressed 5 times
32 - Key Held Down
64 - Key Released

Values of parameter 30 may be combined, e.g. 1+2=3 means that alarm frames will be sent after pressing the button once or twice.

Property Value
Configuration ID config_30_1
Data Type INTEGER
Range 1 to 127
Default Value 127

1: Lifeline

reports the device status and allows for assigning single device only (main controller by default)

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: On/Off

assigned to clicking the button and is used to turn on/off associated devices

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Dimmer

is assigned to holding the button and is used to change level of associated devices

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Alarm

assigned to clicking and/or holding the button (triggers are defined in parameter 30) and is used to send alarm frames to associated devices

Property Value
Configuration ID group_4
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.