FGR221 Roller Shutter Controller

This describes the Z-Wave device FGR221, manufactured by Fibargroup with the thing type UID of fibaro_fgr221_00_000.

Roller Shutter Controller

Channels

The following table summarises the channels available for the FGR221 Roller Shutter Controller.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Blinds control blinds_control blinds_control Blinds Rollershutter

Blinds control

Invert control

Invert the blinds control

Property Value      
Configuration ID config_invert_control      
Data Type BOOLEAN   Default Value false
Options Yes (true)      
  No (false)      

Invert percentage value

Invert the blinds percentage value

Property Value      
Configuration ID config_invert_percent      
Data Type BOOLEAN   Default Value false
Options Yes (true)      
  No (false)      

Step duration

Sets the dim rate speed
Values from 1 to 127 are defined in seconds, while values from 128 to 254 are defined in minutes.

Property Value      
Configuration ID config_duration      
Data Type INTEGER      
Range 1 to 254   Default Value 255
Options Device Default (255)      
  Change Instantly (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the FGR221 Roller Shutter Controller. Detailed information on each parameter can be found below.

Parameter Description
1: Enable/Disable ALL ON/OFF Activate/Deactive ALL ON/OFF
10: Control key #2 behaviour Turning off the shutter positioning function
14: Inputs Button/Switch configuration Binary inputs type configuration
20: Dimmer/Roller shutter control Options for changing parameter 1-99, default 16
30: General Alarm set for shutter no. 1
31: Alarm of flooding with water set for relay the shutter
32: Smoke, CO, CO2 Alarm. Set for the roller shutter.
33: Temperature Alarm set for roller shutter
41: Scene activation functionality Only valid for the 1.9 version of FGR221.
1: Group 1  
2: Group 2  
3: Controller Updates  

1: Enable/Disable ALL ON/OFF

Activate/Deactive ALL ON/OFF

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 255
Options ALL ON active / ALL OFF active (-1)      
  ALL ON disabled/ ALL OFF disabled (0)      
  ALL ON disabled/ ALL OFF active (1)      
  ALL ON active / ALL OFF disabled (2)      

10: Control key #2 behaviour

Turning off the shutter positioning function

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 0
Options Turning on the shutter positioning function - Default (0)      
  Turning off the shutter positioning function (1)      

14: Inputs Button/Switch configuration

Binary inputs type configuration

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 0
Options Mono-stable input (button) (0)      
  Bi-stable input (switch) (1)      
  Single Mono-stable switch (2)      

20: Dimmer/Roller shutter control

Options for changing parameter 1-99, default 16

Property Value
Configuration ID config_20_1
Data Type INTEGER
Range 0 to 255
Default Value 16

30: General Alarm

set for shutter no. 1

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 2
Options DEACTIVATION (0)      
  OPEN SHUTTER ALARM (1)      
  CLOSED SHUTTER ALARM (2)      

31: Alarm of flooding with water

set for relay the shutter

Property Value      
Configuration ID config_31_1      
Data Type INTEGER   Default Value 0
Options DEACTIVATION (0)      
  OPEN SHUTTER ALARM (1)      
  CLOSED SHUTTER ALARM (2)      

32: Smoke, CO, CO2 Alarm.

Set for the roller shutter.

Property Value      
Configuration ID config_32_1      
Data Type INTEGER   Default Value 1
Options DEACTIVATION (0)      
  OPEN SHUTTER ALARM (1)      
  CLOSED SHUTTER ALARM (2)      

33: Temperature Alarm

set for roller shutter

Property Value      
Configuration ID config_33_1      
Data Type INTEGER   Default Value 1
Options DEACTIVATION (0)      
  OPEN SHUTTER ALARM (1)      
  CLOSED SHUTTER ALARM (2)      

41: Scene activation functionality

Only valid for the 1.9 version of FGR221.

Overview

The device offers the possibility of sending commands compatible with Command class scene activation. Information is sent to devices assigned to association group no. 3.

Property Value      
Configuration ID config_41_1      
Data Type INTEGER   Default Value 0
Options Deactivation of functionality - Default (0)      
  Activation of functionality (1)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Controller Updates

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.