FGRGBW RGBW Controller

This describes the Z-Wave device FGRGBW, manufactured by Fibargroup with the thing type UID of fibaro_fgrgbw_00_000.

RGBW Controller

Channels

The following table summarises the channels available for the FGRGBW RGBW Controller.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Sensor (power) sensor_power sensor_power Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Color color_color color_color   Color
Start animation scene_number_param72 scene_number   Number
Red switch_dimmer2 switch_dimmer DimmableLight Dimmer
Green switch_dimmer3 switch_dimmer DimmableLight Dimmer
Blue switch_dimmer4 switch_dimmer DimmableLight Dimmer
White switch_dimmer5 switch_dimmer DimmableLight Dimmer

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Red

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Green

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Blue

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

White

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the FGRGBW RGBW Controller. Detailed information on each parameter can be found below.

Parameter Description
1: ALL ON / ALL OFF function activation Activation/deactivation of ALL ON/ALL OFF functions.
6: Associations command class choice Associations command class choice. By default, Normal (Dimmer) - BASIC_SET/SWITCH_MULTIL…
8: Outputs state change mode MODE1, Example: change saturation level from 0% to 99% Parameter 9: Step = 5 Parameter 10:…
9: Step value (relevant for MODE1) Step value (relevant for MODE1).
10: Time between steps (relevant for MODE1) Time between steps (relevant for MODE1).
11: Time for changing from start to end value Step value (relevant for MODE1).
12: Maximum Brightening level Maximum Brightening level.
13: Minimum dim level Minimum dim level. Default setting: 2 Available settings: 3 - 255.
14: Inputs/Outputs configuration - relevant for main controllers other than Home Center 2 only Inputs/Outputs configuration - relevant for main controllers other than Home Center 2 only…
16: Remember device status after power failure Define how will the Plug react after the power supply is back on. Default setting: 1 Avail…
30: Alarm of any type (General alarm, flood alarm, smoke alarm: CO, CO2, temperature alarm.) Alarm of any type (General alarm, flood alarm, smoke alarm: CO, CO2, temperature alarm.) D…
38: Alarm sequence program Alarm sequence program.
39: Active PROGRAM alarm time IActive PROGRAM alarm time.
42: Command class reporting Outputs status change Command class reporting Outputs status change. Default setting: 0
43: Reporting 0-10v analog inputs change threshold Parameter defines a value by which input voltage must change in order to be reported to th…
44: Power load reporting frequency Parameter defines Time between reports. The report will be sent if last reported value dif…
45: Reporting Changes in energy consumed by controlled devices Defines the required change in power to generate an unsolicited power report.
71: Response to BRIGHTNESS set to 0% Response to BRIGHTNESS set to 0%. Default setting: 1
72: Starting animation program Starting animation programm. Starting predefined program when device set to work in RGB/RG…
73: Triple click action Triple click action. Default setting: 0
1: Assigned to IN1 input  
2: Assigned to IN2 input  
3: Assigned to IN3 input  
4: Assigned to IN4 input  
5: Reports device status  

1: ALL ON / ALL OFF function activation

Activation/deactivation of ALL ON/ALL OFF functions.

Overview

By default, ALL ON active ALL OFF active.

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 255
Options ALL ON active ALL OFF active (-1)      
  ALL ON inactive ALL OFF inactive (0)      
  ALL ON inactive ALL OFF active (1)      
  ALL ON active ALL OFF inactive (2)      

6: Associations command class choice

Associations command class choice. By default, Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP. Default setting: Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 0
Options Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP (0)      
  Normal (RGBW) - COLOR_CONTROL_SET/START/STOP_STATE_CHANGE (1)      
  Normal (RGBW) - COLOR_CONTROL_SET (2)      
  Brightness - BASIC_SET/SWITCH_MULTILEVEL_START/STOP (3)      
  Rainbow (RGBW) - COLOR_CONTROL_SET (4)      

8: Outputs state change mode

MODE1, Example: change saturation level from 0% to 99% Parameter 9: Step = 5 Parameter 10: Time between steps: 10ms. Default setting: MODE1

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 0
Options MODE1 (related parameters: 9-step value, 10-time between steps) (0)      
  MODE2 (related parameters: 11-time to change value, relevant for RGB/R (1)      

9: Step value (relevant for MODE1)

Step value (relevant for MODE1).
Default setting: 1
Available settings: 1 - 255.

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 1 to 255
Default Value 1

10: Time between steps (relevant for MODE1)

Time between steps (relevant for MODE1).
Default setting: 10 ms
0 - immediate change of state
Available settings: 1 - 60000 ms.

Property Value
Configuration ID config_10_2
Data Type INTEGER
Range 0 to 60000
Default Value 10

11: Time for changing from start to end value

Step value (relevant for MODE1).
Default setting: 67 (3s)
0: immediate change
1-63: 20-126 [ms] value*20ms
65-127: 1-63 [s] (value-64)*1s
129-191: 10-630 [s] (value-128)*10s

Property Value
Configuration ID config_11_1
Data Type INTEGER
Range 1 to 255
Default Value 67

12: Maximum Brightening level

Maximum Brightening level.
Default setting: 255
Available settings: 3 - 255.

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 3 to 255
Default Value 255

13: Minimum dim level

Minimum dim level. Default setting: 2 Available settings: 3 - 255.

Property Value
Configuration ID config_13_1
Data Type INTEGER
Range 2 to 255
Default Value 2

14: Inputs/Outputs configuration - relevant for main controllers other than Home Center 2 only

Inputs/Outputs configuration - relevant for main controllers other than Home Center 2 only.
Default setting: 4369
Controlled device: RGBW, toggle switch inputs (NORMAL MODE).

Property Value
Configuration ID config_14_2
Data Type INTEGER
Range 0 to 65535
Default Value 4369

16: Remember device status after power failure

Define how will the Plug react after the power supply is back on. Default setting: 1 Available settings: 0 - Device does not memorize its state aft

Property Value      
Configuration ID config_16_1      
Data Type INTEGER   Default Value 1
Options Do not remember state (0)      
  Remember state before power failure (1)      

30: Alarm of any type (General alarm, flood alarm, smoke alarm: CO, CO2, temperature alarm.)

Alarm of any type (General alarm, flood alarm, smoke alarm: CO, CO2, temperature alarm.) Default setting: INACTIVE

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options INACTIVE - the device doesn't respond to alarm frames (0)      
  ALARM ON - the device turns on once alarm is detected (all channels se (1)      
  ALARM OFF - the device turns off once alarm is detected (all channels (2)      
  ALARM PROGRAM - alarm sequence turns on (program selected in parameter (3)      

38: Alarm sequence program

Alarm sequence program.
Default setting: 10
1-10 specifies alarm program number.

Property Value
Configuration ID config_38_1
Data Type INTEGER
Range 1 to 10
Default Value 10

39: Active PROGRAM alarm time

IActive PROGRAM alarm time.
Default setting: 600s
1-65534 specifies alarm time in seconds.

Property Value
Configuration ID config_39_2
Data Type INTEGER
Range 1 to 65534
Default Value 600

42: Command class reporting Outputs status change

Command class reporting Outputs status change. Default setting: 0

Property Value      
Configuration ID config_42_1      
Data Type INTEGER   Default Value 0
Options Reporting as a result of inputs and controllers actions (SWITCH MULTIL (0)      
  Reporting as a result of inputs actions (SWITCH MULTILEVEL) (1)      
  Reporting as a result of inputs actions (COLOR CONTROL) (2)      

43: Reporting 0-10v analog inputs change threshold

Parameter defines a value by which input voltage must change in order to be reported to the main controller.
New value is calculated based on last reported value.
Default setting: 5

Property Value
Configuration ID config_43_1
Data Type INTEGER
Range 1 to 100
Default Value 5

44: Power load reporting frequency

Parameter defines Time between reports. The report will be sent if last reported value differs from the current value, else reports will also be sent in case of polling.
Default setting: 3 600 (s)

Property Value
Configuration ID config_44_2
Data Type INTEGER
Range 1 to 65534
Default Value 30

45: Reporting Changes in energy consumed by controlled devices

Defines the required change in power to generate an unsolicited power report.
New, reported energy value is calculated based on last reported value.
Default setting: 10 (0,1 kWh).

Property Value
Configuration ID config_45_1
Data Type INTEGER
Range 1 to 255
Default Value 1

71: Response to BRIGHTNESS set to 0%

Response to BRIGHTNESS set to 0%. Default setting: 1

Property Value      
Configuration ID config_71_1      
Data Type INTEGER   Default Value 1
Options illumination colour set to white (all channels controlled together) (0)      
  last set colour is memorized (1)      

72: Starting animation program

Starting animation programm. Starting predefined program when device set to work in RGB/RGBW mode (parameter 14) - relevant for main controllers other than Home Center 2 only. Default setting: 1

Property Value
Configuration ID config_72_1
Data Type INTEGER
Range 1 to 10
Default Value 1

73: Triple click action

Triple click action. Default setting: 0

Property Value      
Configuration ID config_73_1      
Data Type INTEGER   Default Value 0
Options NODE INFO control frame is sent (0)      
  starting favourite program (1)      

1: Assigned to IN1 input

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Assigned to IN2 input

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Assigned to IN3 input

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Assigned to IN4 input

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Reports device status

Property Value
Configuration ID group_5
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.