FGRM222 Roller Shutter

This describes the Z-Wave device FGRM222, manufactured by Fibargroup with the thing type UID of fibaro_fgrm222_00_000.

Roller Shutter

Channels

The following table summarises the channels available for the FGRM222 Roller Shutter.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Blinds control blinds_control blinds_control Blinds Rollershutter
Scene Number scene_number scene_number   Number
Sensor (power) sensor_power sensor_power Energy Number
Meter (watts) meter_watts meter_watts Energy Number
Meter (kWh) meter_kwh meter_kwh Energy Number

Blinds control

Invert control

Invert the blinds control

Property Value      
Configuration ID config_invert_control      
Data Type BOOLEAN   Default Value false
Options Yes (true)      
  No (false)      

Invert percentage value

Invert the blinds percentage value

Property Value      
Configuration ID config_invert_percent      
Data Type BOOLEAN   Default Value false
Options Yes (true)      
  No (false)      

Step duration

Sets the dim rate speed
Values from 1 to 127 are defined in seconds, while values from 128 to 254 are defined in minutes.

Property Value      
Configuration ID config_duration      
Data Type INTEGER      
Range 1 to 254   Default Value 255
Options Device Default (255)      
  Change Instantly (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the FGRM222 Roller Shutter. Detailed information on each parameter can be found below.

Parameter Description
1: Local protection Enables/disables local entry. If activated module stops responding to S1 and S2 push butto…
2: Radio protection Enables/disables RF protection. If activated device stops responding to command frames. Co…
3: Reports type Parameters value shoud be set to 1 if the module operates in Venetian Blind mode.
10: Roller Shutter operating modes  
12: Turning time/ delay time In Venetian Blind mode (parameter 10 set to 2) the parameter determines time of full turn …
13: Lamellas positioning mode Parameter influences the lamellas positioning in venetian blind mode (parameter 10 set to …
14: Switch type parameter settings are relevant for Roller Blind Mode and Venetian Blind Mode (parameter 1…
17: Delay time after S2 In roller blind mode or venetian blind mode (parameter 10 set to 0, 1, 2) the parameter de…
18: Motor operation detection Power threshold to be interpreted as reaching a limit switch.
22: Motor operation time Time period for the motor to continue operation.
29: Forced Roller Shutter calibration Seting the parameter to 1 Roller Shutter enters the calibration mode. Parameter is only on…
30: Response to General Alarm  
31: Response to Water Flood Alarm  
32: Response to Smoke, CO, CO2 Alarm  
33: Response to Temperature Alarm  
35: Managing lamellas in response to alarm In Venetian Blind Mode (parameter 10 set to 2), the parameter determines how the lamellas …
40: Power reports Power level change that will result in new power value report being sent. value is a perce…
42: Periodic power or energy reports Time to the next report. Value of 0 means the reports are turned off.
43: Energy reports Energy level change which will result in new energy value report being sent. Value of 0 me…
44: Self-measurement Enables/disables to include the power and energy used by itself in reports to main control…
50: Scenes/ Associations activation Parameter determines whether scenes or associations are activated by the switch keys.
1: Momentary click  
2: Momentary hold  
3: Controller Updates  

1: Local protection

Enables/disables local entry. If activated module stops responding to S1 and S2 push buttons, SCENE ID and association commands will not be sent. Only exception is the B-button.

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 255
Options No protection. Roller Shutter responds to push buttons (0)      
  Local protection active. Roller Shutter does not respond to push butto (2)      

2: Radio protection

Enables/disables RF protection. If activated device stops responding to command frames. Configuration and polling still possible.

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options No protection. Roller Shutter responds to command frames. (0)      
  RF Protection active. Roller Shutter does not respond to the Z-Wave co (1)      

3: Reports type

Parameters value shoud be set to 1 if the module operates in Venetian Blind mode.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Blind position reports sent to the main controller using Z-Wave Comman (0)      
  Blind position reports sent to the main controller using Fibar Command (1)      

10: Roller Shutter operating modes

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 1
Options Roller Blind Mode, without positioning (0)      
  Roller Blind Mode, with positioning (1)      
  Venetian Blind Mode, with positioning (2)      
  Gate Mode, without positioning (3)      
  Gate Mode, with positioning (4)      

12: Turning time/ delay time

In Venetian Blind mode (parameter 10 set to 2) the parameter determines time of full turn of the lamellas. In Gate Mode (parameter 10 set to 3 or 4) the parameter defines the delay time after which an open gate starts closing. Type range

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 65535
Default Value 150

13: Lamellas positioning mode

Parameter influences the lamellas positioning in venetian blind mode (parameter 10 set to 2)

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 1
Options Lamellas return to previously set position only in case of the main co (0)      
  Lamellas return to previously set position in case of the main control (1)      
  Lamellas return to previously set position in case of the main control (2)      

14: Switch type

parameter settings are relevant for Roller Blind Mode and Venetian Blind Mode (parameter 10 set to 0, 1, 2).

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 0
Options Momentary switches (0)      
  Toggle switches (1)      
  Single, momentary switch. (2)      

17: Delay time after S2

In roller blind mode or venetian blind mode (parameter 10 set to 0, 1, 2) the parameter determines when the Roller Shutter relays are turned off after reaching a limit switch. In Gate Mode (parameter 10 set to 3 or 4) the parameter determines a time perio

Property Value
Configuration ID config_17_1
Data Type INTEGER
Range 0 to 255
Default Value 10

18: Motor operation detection

Power threshold to be interpreted as reaching a limit switch.

Property Value
Configuration ID config_18_1
Data Type INTEGER
Range 0 to 255
Default Value 10

22: Motor operation time

Time period for the motor to continue operation.

Property Value
Configuration ID config_22_2
Data Type INTEGER
Range 0 to 65535
Default Value 10

29: Forced Roller Shutter calibration

Seting the parameter to 1 Roller Shutter enters the calibration mode. Parameter is only only relevant if a Roller Shutter is set to work in positioning mode (parameter 10 set to 1, 2 or 4).

Property Value      
Configuration ID config_29_1      
Data Type INTEGER   Default Value 0
Options Deactivated (0)      
  Start calibration process (1)      

30: Response to General Alarm

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 2
Options No response to alarm frames (0)      
  Open Blind (1)      
  Close Blind (2)      

31: Response to Water Flood Alarm

Property Value      
Configuration ID config_31_1      
Data Type INTEGER   Default Value 0
Options No response to alarm frames (0)      
  Open Blind (1)      
  Close Blind (2)      

32: Response to Smoke, CO, CO2 Alarm

Property Value      
Configuration ID config_32_1      
Data Type INTEGER   Default Value 3
Options No response to alarm frames (0)      
  Open Blind (1)      
  Close Blind (2)      

33: Response to Temperature Alarm

Property Value      
Configuration ID config_33_1      
Data Type INTEGER   Default Value 1
Options No response to alarm frames (0)      
  Open Blind (1)      
  Close Blind (2)      

35: Managing lamellas in response to alarm

In Venetian Blind Mode (parameter 10 set to 2), the parameter determines how the lamellas will react upon alarm detection.

Property Value      
Configuration ID config_35_1      
Data Type INTEGER   Default Value 1
Options Do not change lamellas position (0)      
  Set lamellas to their extreme position (1)      

40: Power reports

Power level change that will result in new power value report being sent. value is a percentage of the previous report.

Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 0 to 100
Default Value 10

42: Periodic power or energy reports

Time to the next report. Value of 0 means the reports are turned off.

Property Value
Configuration ID config_42_2
Data Type INTEGER
Range -32767 to 32767
Default Value 3600

43: Energy reports

Energy level change which will result in new energy value report being sent. Value of 0 means the reports are turned off.

Property Value
Configuration ID config_43_1
Data Type INTEGER
Range -126 to 127
Default Value 10

44: Self-measurement

Enables/disables to include the power and energy used by itself in reports to main controller.

Property Value      
Configuration ID config_44_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Activated (1)      

50: Scenes/ Associations activation

Parameter determines whether scenes or associations are activated by the switch keys.

Property Value      
Configuration ID config_50_1      
Data Type INTEGER   Default Value 0
Options Associations Active (0)      
  Scenes Active (1)      

1: Momentary click

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Momentary hold

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Controller Updates

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.