FGS211 Relay Switch 1x3kW

This describes the Z-Wave device FGS211, manufactured by Fibargroup with the thing type UID of fibaro_fgs211_00_000.

Relay Switch 1x3kW

Channels

The following table summarises the channels available for the FGS211 Relay Switch 1x3kW.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Switch 2 switch_binary2 switch_binary Switch Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the FGS211 Relay Switch 1x3kW. Detailed information on each parameter can be found below.

Parameter Description
1: Enable/Disable ALL ON/OFF Activate/Deactive ALL ON/OFF
3: Enable/Disable OFF-delay Activate/Deactivate Automatic turning off relay after set time
4: Relay 1: OFF-delay time (10ms steps) Automatic turning off relay 1 after set time, in 10ms increments (default: 200ms)
6: Separation of association sending (key 1) Activate/Deactivate association sending for group 1 - Also see param #16
13: Inputs behaviour In case of bi-stable switches, define their behaviour (toggle or follow)
14: Inputs Button/Switch configuration Binary inputs type configuration
15: Dimmer/Roller shutter control Enable/Disable operation of dimmer or roller shutter devices associated to group 1. Availa…
16: Saving state before power failure Saving state before power failure
30: Relay 1: Response to General Alarm  
31: Relay 1: Response to Water Flood Alarm  
32: Relay 1: Response to Smoke, CO, CO2 Alarm  
33: Relay 1: Response to Temperature Alarm  
39: ALARM FLASHING alarm time Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame
1: Switch 1  
2: Switch 2  
3: Controller Updates  

1: Enable/Disable ALL ON/OFF

Activate/Deactive ALL ON/OFF

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 255
Options ALL ON active / ALL OFF active (-1)      
  ALL ON disabled / ALL OFF disabled (0)      
  ALL ON disabled / ALL OFF active (1)      
  ALL ON active / ALL OFF disabled (2)      

3: Enable/Disable OFF-delay

Activate/Deactivate Automatic turning off relay after set time

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Auto OFF disabled for both relays (0)      
  Auto OFF active only for relay 1 (1)      

4: Relay 1: OFF-delay time (10ms steps)

Automatic turning off relay 1 after set time, in 10ms increments (default: 200ms)

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 255
Default Value 20

6: Separation of association sending (key 1)

Activate/Deactivate association sending for group 1 - Also see param #16

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 0
Options Map status to all devices in group 1 (0)      
  Map OFF status to all devices in group 1, Double click on key 1 will s (1)      
  Map OFF status to all devices in group 1, Double click on key 1 will s (2)      

13: Inputs behaviour

In case of bi-stable switches, define their behaviour (toggle or follow)

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 0
Options Toggle (0)      
  Follow switch contact (closed=ON, open=OFF) (1)      

14: Inputs Button/Switch configuration

Binary inputs type configuration

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 1
Options Mono-stable input (button) (0)      
  Bi-stable input (switch) (1)      

15: Dimmer/Roller shutter control

Enable/Disable operation of dimmer or roller shutter devices associated to group 1. Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation

Property Value      
Configuration ID config_15_1      
Data Type INTEGER   Default Value 0
Options Disable Dimmer/Roller shutter control (0)      
  Enable Dimmer/Roller shutter control (1)      

16: Saving state before power failure

Saving state before power failure

Property Value      
Configuration ID config_16_1      
Data Type INTEGER   Default Value 1
Options State NOT saved at power failure, all outputs are set to OFF upon powe (0)      
  State saved at power failure, all outputs are set to previous state up (1)      

30: Relay 1: Response to General Alarm

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 3
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt of alarm frame (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame (2)      
  ALARM FLASHING - relay will turn ON and OFF periodically (see param.39 (3)      

31: Relay 1: Response to Water Flood Alarm

Property Value      
Configuration ID config_31_1      
Data Type INTEGER   Default Value 2
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt of alarm frame (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame (2)      
  ALARM FLASHING - relay will turn ON and OFF periodically (see param.39 (3)      

32: Relay 1: Response to Smoke, CO, CO2 Alarm

Property Value      
Configuration ID config_32_1      
Data Type INTEGER   Default Value 3
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt of alarm frame (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame (2)      
  ALARM FLASHING - relay will turn ON and OFF periodically (see param.39 (3)      

33: Relay 1: Response to Temperature Alarm

Property Value      
Configuration ID config_33_1      
Data Type INTEGER   Default Value 1
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt of alarm frame (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame (2)      
  ALARM FLASHING - relay will turn ON and OFF periodically (see param.39 (3)      

39: ALARM FLASHING alarm time

Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame

Property Value
Configuration ID config_39_2
Data Type INTEGER
Range 0 to 65535
Default Value 600

1: Switch 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Switch 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Controller Updates

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.