FGS212 Relay Switch 1x2.5kW

This describes the Z-Wave device FGS212, manufactured by Fibargroup with the thing type UID of fibaro_fgs212_00_000.

Relay Switch 1x2.5kW

Channels

The following table summarises the channels available for the FGS212 Relay Switch 1x2.5kW.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Switch 2 switch_binary2 switch_binary Switch Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the FGS212 Relay Switch 1x2.5kW. Detailed information on each parameter can be found below.

Parameter Description
1: Enable/Disable ALL ON/OFF Activate/Deactive ALL ON/OFF
3: Override OFF-delay Forced auto off period
4: Relay 1: OFF-delay time (100ms steps) Automatic turning off relay 1 after set time …
6: Separation of association sending (key 1) Sending commands to control devices assigned …
13: Inputs behaviour Assigns bistable key status to the device status.
14: Inputs Button/Switch configuration Binary inputs type configuration
15: Dimmer/Roller shutter control Enable/Disable operation of dimmer or roller shutter devices …
16: Saving state before power failure Saving state before power failure
30: Relay 1: Response to General Alarm  
31: Relay 1: Response to Water Flood Alarm  
32: Relay 1: Response to Smoke, CO, CO2 Alarm  
33: Relay 1: Response to Temperature Alarm  
39: ALARM FLASHING alarm time Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame
1: Switch 1  
2: Switch 2  
3: Controller Updates  

1: Enable/Disable ALL ON/OFF

Activate/Deactive ALL ON/OFF

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 255
Options ALL ON disabled / ALL OFF disabled (0)      
  ALL ON disabled / ALL OFF active (1)      
  ALL ON active / ALL OFF disabled (2)      
  ALL ON active / ALL OFF active (255)      

3: Override OFF-delay

Forced auto off period

Overview

If Parameter 4 states an auto off period, this parameter enable the possibility to turn off the relay with a button push. Default value 0 disallow turn off with a button push during the auto off interval.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Turn off with push button disabled in auto off interval (0)      
  Turn off with push button enabled in auto off interval (1)      

4: Relay 1: OFF-delay time (100ms steps)

Automatic turning off relay 1 after set time …

Overview

Default: 0 (Auto off disabled). In 100ms increments.

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

6: Separation of association sending (key 1)

Sending commands to control devices assigned …

Overview

to 1-st association group (key no. 1)

- Also see param #15

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 0
Options Map status to all devices in group 1 (0)      
  Map OFF status to all devices in group 1 … (1)      
  Map OFF status to all devices in group 1 … (2)      

13: Inputs behaviour

Assigns bistable key status to the device status.

Overview

Available configuration parameters:
0 - [On / Off] device changes status on key status change.
1 - Device status depends on key status: ON when the key is ON, OFF when the key is OFF

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 0
Options Toggle (0)      
  Follow switch contact (closed=ON, open=OFF) (1)      

14: Inputs Button/Switch configuration

Binary inputs type configuration

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 1
Options Mono-stable input (button) (0)      
  Bi-stable input (switch) (1)      

15: Dimmer/Roller shutter control

Enable/Disable operation of dimmer or roller shutter devices …

Overview

enabling this option allows the user to dim lighting/shut roller by associating Dimmer/Roller Shutter Controller and holding or double press of double switch (only mono-stable switch).

Property Value      
Configuration ID config_15_1      
Data Type INTEGER   Default Value 0
Options Disable Dimmer/Roller shutter control (0)      
  Enable Dimmer/Roller shutter control (1)      

16: Saving state before power failure

Saving state before power failure

Property Value      
Configuration ID config_16_1      
Data Type INTEGER   Default Value 1
Options State NOT saved at power failure, all outputs are set … (0)      
  State saved at power failure, all outputs are set to … (1)      

30: Relay 1: Response to General Alarm

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 3
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt … (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt … (2)      
  ALARM FLASHING - relay will turn ON and OFF … (3)      

31: Relay 1: Response to Water Flood Alarm

Property Value      
Configuration ID config_31_1      
Data Type INTEGER   Default Value 2
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt … (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt … (2)      
  ALARM FLASHING - relay will turn ON and OFF … (3)      

32: Relay 1: Response to Smoke, CO, CO2 Alarm

Property Value      
Configuration ID config_32_1      
Data Type INTEGER   Default Value 3
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt … (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt … (2)      
  ALARM FLASHING - relay will turn ON and OFF … (3)      

33: Relay 1: Response to Temperature Alarm

Property Value      
Configuration ID config_33_1      
Data Type INTEGER   Default Value 1
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt … (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt … (2)      
  ALARM FLASHING - relay will turn ON and OFF … (3)      

39: ALARM FLASHING alarm time

Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame

Property Value
Configuration ID config_39_2
Data Type INTEGER
Range 0 to 65535
Default Value 600

1: Switch 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Switch 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Controller Updates

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.