FGS221 Double Relay Switch 2x1.5kW

This describes the Z-Wave device FGS221, manufactured by Fibargroup with the thing type UID of fibaro_fgs221_01_009.

Double Relay Switch 2x1.5kW

Channels

The following table summarises the channels available for the FGS221 Double Relay Switch 2x1.5kW.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Switch 2 switch_binary2 switch_binary Switch Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the FGS221 Double Relay Switch 2x1.5kW. Detailed information on each parameter can be found below.

Parameter Description
1: Enable/Disable ALL ON/OFF Activate/Deactive ALL ON/OFF
3: Enable/Disable Manual Override Enable / Disable manual override for relay auto off
4: Relay 1: OFF-delay time Automatic turning off relay 1 after set time in milliseconds, 0 to disable
5: Relay 2: OFF-delay time Automatic turning off relay 2 after set time in milliseconds, 0 to disable
6: Separation of association sending (key 1) Activate/Deactivate association sending for group 1 - Also see param #16
7: Control key #2 behaviour Key no.2 is not represented by any physical device - only devices in the association list….
13: Inputs behaviour In case of bi-stable switches, define their behaviour (toggle or follow)
14: Inputs Button/Switch configuration Binary inputs type configuration
15: Dimmer/Roller shutter control Enable/Disable operation of dimmer or roller shutter devices associated to group 1. Availa…
16: Saving state before power failure Saving state before power failure
30: Relay 1: Response to General Alarm  
31: Relay 1: Response to Water Flood Alarm  
32: Relay 1: Response to Smoke, CO, CO2 Alarm  
33: Relay 1: Response to Temperature Alarm  
39: ALARM FLASHING alarm time Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame
40: Relay 2: Response to General Alarm  
41: Relay 2: Response to Water Flood Alarm  
42: Relay 2: Response to Smoke, CO, CO2 Alarm  
43: Relay 2: Response to Temperature Alarm  
1: Switch 1  
2: Switch 2  
3: Controller Updates  

1: Enable/Disable ALL ON/OFF

Activate/Deactive ALL ON/OFF

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 255
Options ALL ON active / ALL OFF active (-1)      
  ALL ON disabled/ ALL OFF disabled (0)      
  ALL ON disabled/ ALL OFF active (1)      
  ALL ON active / ALL OFF disabled (2)      

3: Enable/Disable Manual Override

Enable / Disable manual override for relay auto off

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Manual Override Disabled (0)      
  Manual Override Enabled (1)      

4: Relay 1: OFF-delay time

Automatic turning off relay 1 after set time in milliseconds, 0 to disable

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

5: Relay 2: OFF-delay time

Automatic turning off relay 2 after set time in milliseconds, 0 to disable

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

6: Separation of association sending (key 1)

Activate/Deactivate association sending for group 1 - Also see param #16

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 0
Options Map status to all devices in group 1 (0)      
  Map OFF status to all devices in group 1, Double click on key 1 will s (1)      
  Map OFF status to all devices in group 1, Double click on key 1 will s (2)      

7: Control key #2 behaviour

Key no.2 is not represented by any physical device - only devices in the association list. This functionality prevents of lack of reaction on pressing key no.2 through polling devices from association list one by one and checking their

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 1
Options Device status is not checked (0)      
  Device status is checked (1)      

13: Inputs behaviour

In case of bi-stable switches, define their behaviour (toggle or follow)

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 0
Options Toggle (0)      
  Follow switch contact (closed=ON, open=OFF) (1)      

14: Inputs Button/Switch configuration

Binary inputs type configuration

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 1
Options Mono-stable input (button) (0)      
  Bi-stable input (switch) (1)      

15: Dimmer/Roller shutter control

Enable/Disable operation of dimmer or roller shutter devices associated to group 1. Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation

Property Value      
Configuration ID config_15_1      
Data Type INTEGER   Default Value 0
Options Disable Dimmer/Roller shutter control (0)      
  Enable Dimmer/Roller shutter control (1)      

16: Saving state before power failure

Saving state before power failure

Property Value      
Configuration ID config_16_1      
Data Type INTEGER   Default Value 1
Options State NOT saved at power failure, all outputs are set to OFF upon powe (0)      
  State saved at power failure, all outputs are set to previous state up (1)      

30: Relay 1: Response to General Alarm

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 3
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt of alarm frame (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame (2)      
  ALARM FLASHING - relay will turn ON and OFF periodically (see param.39 (3)      

31: Relay 1: Response to Water Flood Alarm

Property Value      
Configuration ID config_31_1      
Data Type INTEGER   Default Value 2
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt of alarm frame (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame (2)      
  ALARM FLASHING - relay will turn ON and OFF periodically (see param.39 (3)      

32: Relay 1: Response to Smoke, CO, CO2 Alarm

Property Value      
Configuration ID config_32_1      
Data Type INTEGER   Default Value 3
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt of alarm frame (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame (2)      
  ALARM FLASHING - relay will turn ON and OFF periodically (see param.39 (3)      

33: Relay 1: Response to Temperature Alarm

Property Value      
Configuration ID config_33_1      
Data Type INTEGER   Default Value 1
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt of alarm frame (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame (2)      
  ALARM FLASHING - relay will turn ON and OFF periodically (see param.39 (3)      

39: ALARM FLASHING alarm time

Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame

Property Value
Configuration ID config_39_2
Data Type INTEGER
Range 0 to 65535
Default Value 600

40: Relay 2: Response to General Alarm

Property Value      
Configuration ID config_40_1      
Data Type INTEGER   Default Value 3
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt of alarm frame (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame (2)      
  ALARM FLASHING - relay will turn ON and OFF periodically (see param.39 (3)      

41: Relay 2: Response to Water Flood Alarm

Property Value      
Configuration ID config_41_1      
Data Type INTEGER   Default Value 2
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt of alarm frame (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame (2)      
  ALARM FLASHING - relay will turn ON and OFF periodically (see param.39 (3)      

42: Relay 2: Response to Smoke, CO, CO2 Alarm

Property Value      
Configuration ID config_42_1      
Data Type INTEGER   Default Value 3
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt of alarm frame (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame (2)      
  ALARM FLASHING - relay will turn ON and OFF periodically (see param.39 (3)      

43: Relay 2: Response to Temperature Alarm

Property Value      
Configuration ID config_43_1      
Data Type INTEGER   Default Value 1
Options DEACTIVATION - no response to alarm frames (0)      
  ALARM RELAY ON - relay will turn ON upon receipt of alarm frame (1)      
  ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame (2)      
  ALARM FLASHING - relay will turn ON and OFF periodically (see param.39 (3)      

1: Switch 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Switch 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Controller Updates

Property Value
Configuration ID group_3
Data Type TEXT
Range to