FGS221 Double Relay Switch 2x1.5kW

This describes the Z-Wave device FGS221, manufactured by Fibargroup with the thing type UID of fibaro_fgs221_02_001.

Double Relay Switch 2x1.5kW

Channels

The following table summarises the channels available for the FGS221 Double Relay Switch 2x1.5kW.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Switch 2 switch_binary2 switch_binary Switch Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the FGS221 Double Relay Switch 2x1.5kW. Detailed information on each parameter can be found below.

Parameter Description
1: Activate / deactivate functions ALL ON / ALL OFF Activate / deactivate functions ALL ON / ALL OFF
3: Auto off relay after specified time Auto off relay after specified time
4: Auto off for relay 1 Time period for auto off, in miliseconds 0 - Auto off disabled
5: Auto off for relay 2 Time period for auto off, in miliseconds 0 - Auto off disabled
6: Sending commands to group 1 devices Sending commands to group 1 devices
7: Sending commands to group 2 devices Sending commands to group 2 devices
13: Assigns bistable key status to the device status Assigns bistable key status to the device status
14: Switch type connector Switch type connector, you may choose between momentary and toggle switches
15: Operation of the Dimmer and Roller Shutter Controller Operation of the Dimmer and Roller Shutter Controller
16: Saving the state of the device after a power failure Fibaro Switch returns to the last position saved before a power failure
30: Relay 1: Response to General Alarm  
31: Relay 1: Response to Water Flood Alarm  
32: Relay 1: Response to Smoke, CO, CO2 Alarm  
33: Relay 1: Response to Temperature Alarm  
39: ALARM FLASHING alarm time Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame
40: Relay 2: Response to General Alarm  
41: Relay 2: Response to Water Flood Alarm  
42: Relay 2: Response to Smoke, CO, CO2 Alarm  
43: Relay 2: Response to Temperature Alarm  
1: Switch 1  
2: Switch 2  
3: Controller Updates  

1: Activate / deactivate functions ALL ON / ALL OFF

Activate / deactivate functions ALL ON / ALL OFF

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 255
Options ALL ON is not active ALL OFF is not active (0)      
  ALL ON is not active ALL OFF active (1)      
  ALL ON active ALL OFF is not active (2)      
  ALL ON active, ALL OFF active (255)      

3: Auto off relay after specified time

Auto off relay after specified time

Overview

Auto off relay after specified time, with the possibility of manual override - immediate Off after button push.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Manual override disabled (0)      
  Manual override enabled. (1)      

4: Auto off for relay 1

Time period for auto off, in miliseconds 0 - Auto off disabled

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

5: Auto off for relay 2

Time period for auto off, in miliseconds 0 - Auto off disabled

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

6: Sending commands to group 1 devices

Sending commands to group 1 devices

Overview

Sending commands to control devices assigned to 1-st association group (key no. 1)
NOTE: Parameter 15 value must be set to 1 to work properly. This activates the double-click functionality - dimmer/roller shutter control

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 0
Options Commands are sent when device is turned on and off (0)      
  Commands sent when device off with memorized state (1)      
  Commands are sent when device is turned off (2)      

7: Sending commands to group 2 devices

Sending commands to group 2 devices

Overview

Sending commands to control devices assigned to 2-nd association group (key no. 2).  

Info: Parameter 15 must be set to 1 to make this parameter work properly. This activates the double-click functionality - dimmer/roller shutter control.

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 0
Options Commands are sent when device is turned on and off (0)      
  Commands sent when device off with memorized state (1)      
  Commands are sent when device is turned off (2)      

13: Assigns bistable key status to the device status

Assigns bistable key status to the device status

Overview

Info: Remote control from Fibaro System Is Still Possible. This function is useful When you want display status of external devices, e.g. Motion Sensor, in Fibaro System.

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 0
Options [On / Off] device changes status on key status change (0)      
  Device status depends on key status (1)      

14: Switch type connector

Switch type connector, you may choose between momentary and toggle switches

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 1
Options Momentary switch (0)      
  Toggle switch (1)      

15: Operation of the Dimmer and Roller Shutter Controller

Operation of the Dimmer and Roller Shutter Controller

Overview

Operation of the Dimmer and Roller Shutter Controller - enabling this option allows the user to dim lighting/shut roller by associating dimmer/Roller Shutter Controller and holding or double press of double switch (only mono-stable switch).  

Property Value      
Configuration ID config_15_1      
Data Type INTEGER   Default Value 0
Options Dimmer/Roller Shutter Controller control is not active (0)      
  Dimmer/Roller Shutter Controller control is active (1)      

16: Saving the state of the device after a power failure

Fibaro Switch returns to the last position saved before a power failure

Overview

Options for changing the parameter 0-1

Property Value      
Configuration ID config_16_1      
Data Type INTEGER   Default Value 1
Options Fibaro Switch does not save the state after a power failure (0)      
  Fibaro Switch saves its state before power failure (1)      

30: Relay 1: Response to General Alarm

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 3
Options Alarm deactivation relay 1 (0)      
  Alarm relay 1 on (1)      
  Alarm Relay 1 off (2)      
  Alarm relay 1 flashing (3)      

31: Relay 1: Response to Water Flood Alarm

Property Value      
Configuration ID config_31_1      
Data Type INTEGER   Default Value 2
Options Alarm deactivation relay 1 (0)      
  Alarm relay 1 on (1)      
  Alarm relay 1 off (2)      
  Alarm relay 1 flashing (3)      

32: Relay 1: Response to Smoke, CO, CO2 Alarm

Property Value      
Configuration ID config_32_1      
Data Type INTEGER   Default Value 3
Options Alarm deactivation relay 1 (0)      
  Alarm relay 1 on (1)      
  Alarm relay 1 off (2)      
  Alarm relay 1 flashing (3)      

33: Relay 1: Response to Temperature Alarm

Property Value      
Configuration ID config_33_1      
Data Type INTEGER   Default Value 1
Options Alarm deactivation relay 1 (0)      
  Alarm relay 1 on (1)      
  Alarm relay 1 off (2)      
  Alarm relay 1 flashing (3)      

39: ALARM FLASHING alarm time

Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame

Property Value
Configuration ID config_39_2
Data Type INTEGER
Range 0 to 65535
Default Value 600

40: Relay 2: Response to General Alarm

Property Value      
Configuration ID config_40_1      
Data Type INTEGER   Default Value 3
Options Alarm deactivation relay 2 (0)      
  Alarm relay 2 on (1)      
  Alarm relay 2 off (2)      
  Alarm relay 2 flashing (3)      

41: Relay 2: Response to Water Flood Alarm

Property Value      
Configuration ID config_41_1      
Data Type INTEGER   Default Value 2
Options Alarm deactivation relay 2 (0)      
  Alarm relay 2 on (1)      
  Alarm relay 2 off (2)      
  Alarm relay 2 flashing (3)      

42: Relay 2: Response to Smoke, CO, CO2 Alarm

Property Value      
Configuration ID config_42_1      
Data Type INTEGER   Default Value 3
Options Alarm deactivation relay 2 (0)      
  Alarm relay 2 on (1)      
  Alarm relay 2 off (2)      
  Alarm relay 2 flashing (3)      

43: Relay 2: Response to Temperature Alarm

Property Value      
Configuration ID config_43_1      
Data Type INTEGER   Default Value 1
Options Alarm deactivation relay 2 (0)      
  Alarm relay 2 on (1)      
  Alarm relay 2 off (2)      
  Alarm relay 2 flashing (3)      

1: Switch 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Switch 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Controller Updates

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.