FGS223 Double Switch 2

This describes the Z-Wave device FGS223, manufactured by Fibargroup with the thing type UID of fibaro_fgs223_00_000.

Double Switch 2

Overview

FIBARO Switch 2 is designed to be installed in standard wall switch boxes or anywhere else where it is necessary to control electric devices. FIBARO Switch 2 allows to control connected devices either via the Z-Wave+ network or via a switch connected directly to it and is equipped with active power and energy consumption metering functionality.

Main features of FIBARO Switch 2:

  • Compatible with any Z-Wave or Z-Wave+ Controller,
  • Supports protected mode (Z-Wave network security mode) with
  • AES-128 encryption,
  • Advanced microprocessor control,
  • Active power and energy metering functionality,
  • Works with various types of switches – momentary, toggle, three-way, etc,
  • To be installed in wall switch boxes of dimensions allowing for installation, conforming to provisions of applicable regulations,
  • FIBARO Switch 2 is an extension unit.

Inclusion Information

Put controller into inclusion mode and triple click S1 switch

Exclusion Information

Put controller into exclusion mode and triple click S1 switch

Channels

The following table summarises the channels available for the FGS223 Double Switch 2.

Channel Channel Id Channel Type UID Category Item Type
  switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Scene Number scene_number scene_number   Number
Alarm alarm_general alarm_general Door Switch
Send notification notification_send notification_send   Number
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Switch 2 switch_binary2 switch_binary Switch Switch
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the FGS223 Double Switch 2. Detailed information on each parameter can be found below.

Parameter Description
9: Restore state after power failure Restore state after power failure
10: First channel operating mode First channel - operating mode
11: 1st ch. reaction to switch First channel - reaction to switch for delay/auto ON/OFF modes
12: time parameter for delay/auto ON/OFF modes First channel - time parameter for delay/auto ON/OFF modes
13: 1st ch. pulse time for flashing mode First channel - pulse time for flashing mode
15: 2nd ch. operating mode Second channel - operating mode
16: 2nd ch. reaction to switch Second channel - reaction to switch for delay/auto ON/OFF modes
17: 2nd ch. time parameter for delay Second channel - time parameter for delay/auto ON/OFF modes
18: 2nd ch. pulse time for flashing mode Second channel - pulse time for flashing mode
20: Switch type Switch type
21: Flashing mode - reports Flashing mode - reports
27: Associations in Z-Wave network security mode Associations in Z-Wave network security mode
28: S1 switch - scenes sent S1 switch - scenes sent
29: S2 switch - scenes sent S2 switch - scenes sent
30: S1 assocs. sent to 2nd and 3rd group S1 switch - associations sent to 2nd and 3rd association groups
31: S1 ON val sent to 2nd and 3rd groups S1 switch - Switch ON value sent to 2nd and 3rd association groups
32: S1 OFF val sent to 2nd and 3rd groups S1 switch - Switch ON value sent to 2nd and 3rd association groups
33: S1 DblClick val sent to 2nd and 3rd groups S1 switch - Double Click value sent to 2nd and 3rd association groups
35: S2 assocs. sent to 4th and 5th group S2 switch - associations sent to 4th and 5th association groups
36: S2 ON val sent to 4th and 5th groups S2 switch - Switch ON value sent to 4th and 5th association groups
36: S2 ON val sent to 4th and 5th groups S2 switch - Switch ON value sent to 4th and 5th association groups
37: S2 OFF val sent to 4th and 5th groups S2 switch - Switch OFF value sent to 4th and 5th association groups
38: S2 DblClick val sent to 4th and 5th groups  
40: Reaction to General Alarm Reaction to General Alarm
41: Reaction to Flood Alarm Reaction to Flood Alarm
42: Reaction to CO/CO2/Smoke Alarm Reaction to CO/CO2/Smoke Alarm
43: Reaction to Heat Alarm Reaction to Heat Alarm
44: Flashing alarm duration Flashing alarm duration
50: First channel - power reports First channel - power reports
51: 1st ch min time between reports First channel - minimal time between power reports
53: 1st ch energy reports First channel - energy reports
54: Second channel - power reports Second channel - power reports
55: 2nd ch min time between reports Second channel - minimal time between power reports
57: 2nd ch energy reports Second channel - energy reports
58: Periodic power reports Periodic power reports
59: Periodic energy reports Periodic energy reports
60: Include own energy Measuring energy consumed by the device itself
1: Lifeline reports the device status and allows for assigning single device only (main controller by …
2: On/Off (S1) On/Off (S1) is assigned to switch connected to the S1 terminal (uses Basic command class)
3: Dimmer (S1) “Dimmer (S1)” is assigned to switch connected to the S1 terminal (uses Switch Multilevel c…
4: On/Off (S2) On/Off (S2) is assigned to switch connected to the S2 terminal (uses Basic command class)
5: Dimmer (S2) Dimmer (S2) is assigned to switch connected to the S2 terminal (uses Switch Multilevel com…

9: Restore state after power failure

Restore state after power failure

Overview

This parameter determines if the device will return to state prior to the power failure after power is restored.

Property Value      
Configuration ID config_9_1      
Data Type INTEGER   Default Value 1
Options off after power loss (0)      
  restore last state (1)      

10: First channel operating mode

First channel - operating mode

Overview

This parameter allows to choose operating for the 1st channel controlled by the S1 switch.

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 0
Options standard operation (0)      
  delay ON (1)      
  delay OFF (2)      
  auto ON (3)      
  auto OFF (4)      
  flashing mode (5)      

11: 1st ch. reaction to switch

First channel - reaction to switch for delay/auto ON/OFF modes

Overview

This parameter determines how the device in timed mode reacts to pushing the switch connected to the S1 terminal.

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 0
Options cancel mode and set target state (0)      
  no reaction to switch - mode runs until it ends (1)      
  reset timer - start counting from the beginning (2)      

12: time parameter for delay/auto ON/OFF modes

First channel - time parameter for delay/auto ON/OFF modes

Overview

This parameter allows to set time parameter used in timed modes.

Available settings: 0 (0.1s), 1-32000 (1-32000s, 1s step) - time parameter

Default setting: 50 (50s)

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 32000
Default Value 50

13: 1st ch. pulse time for flashing mode

First channel - pulse time for flashing mode

Overview

This parameter allows to set time of switching to opposite state in flashing mode

Available settings: 1-32000 (0.1-3200.0s, 0.1s step) - time parameter

Default setting: 5 (0.5s)

Property Value
Configuration ID config_13_2
Data Type INTEGER
Range 1 to 32000
Default Value 5

15: 2nd ch. operating mode

Second channel - operating mode

Overview

This parameter allows to choose operating for the 1st channel controlled by the S2 switch.

Property Value      
Configuration ID config_15_1      
Data Type INTEGER   Default Value 0
Options standard operation (0)      
  delay ON (1)      
  delay OFF (2)      
  auto ON (3)      
  auto OFF (4)      
  flashing mode (5)      

16: 2nd ch. reaction to switch

Second channel - reaction to switch for delay/auto ON/OFF modes

Property Value      
Configuration ID config_16_1      
Data Type INTEGER   Default Value 0
Options cancel mode and set target state (0)      
  no reaction to switch - mode runs until it ends (1)      
  reset timer - start counting from the beginning (2)      

17: 2nd ch. time parameter for delay

Second channel - time parameter for delay/auto ON/OFF modes

Overview

This parameter allows to set time parameter used in timed modes.

Available settings: 0 (0.1s), 1-32000 (1-32000s, 1s step) - time parameter

Default setting: 50 (50s)

Property Value
Configuration ID config_17_2
Data Type INTEGER
Range 0 to 32000
Default Value 50

18: 2nd ch. pulse time for flashing mode

Second channel - pulse time for flashing mode

Overview

This parameter allows to set time of switching to opposite state in flashing mode

Available settings: 1-32000 (0.1-3200.0s, 0.1s step) - time parameter

Default setting: 5 (0.5s)

Property Value
Configuration ID config_18_2
Data Type INTEGER
Range 1 to 32000
Default Value 5

20: Switch type

Switch type

Overview

This parameter defines as what type the device should treat the switch connected to the S1 and S2 terminals

Property Value      
Configuration ID config_20_1      
Data Type INTEGER   Default Value 2
Options momentary switch (0)      
  toggle switch stable (1)      
  toggle switch (2)      

21: Flashing mode - reports

Flashing mode - reports

Property Value      
Configuration ID config_21_1      
Data Type INTEGER   Default Value 0
Options the device does not send reports (0)      
  the device sends reports (1)      

27: Associations in Z-Wave network security mode

Associations in Z-Wave network security mode

Overview

This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. This parameter does not apply to 1st „Lifeline” group.

Property Value      
Configuration ID config_27_1      
Data Type INTEGER   Default Value 15
Options no group sent as secure (0)      
  2nd group sent as secure (1)      
  3rd group sent as secure (2)      
  4th group sent as secure (4)      
  5th group sent as secure (8)      
  all groups sent as secure (15)      

28: S1 switch - scenes sent

S1 switch - scenes sent

Overview

This parameter determines which actions result in sending scene IDs assigned to them

Property Value      
Configuration ID config_28_1      
Data Type INTEGER      
Range 0 to 15   Default Value 0
Options no scenes sent (0)      
  Key pressed 1 time (1)      
  Key pressed 2 times (2)      
  Key pressed 3 times (4)      
  Key Hold Down and Key Released (8)      

29: S2 switch - scenes sent

S2 switch - scenes sent

Overview

This parameter determines which actions result in sending scene IDs assigned to them.

Property Value      
Configuration ID config_29_1      
Data Type INTEGER      
Range 0 to 15   Default Value 0
Options no scenes sent (0)      
  Key pressed 1 time (1)      
  Key pressed 2 times (2)      
  Key pressed 3 times (4)      
  Key Hold Down and Key Released (8)      

30: S1 assocs. sent to 2nd and 3rd group

S1 switch - associations sent to 2nd and 3rd association groups

Overview

This parameter determines which actions are ignored when sending commands to devices associated in 2nd and 3rd association group. All actions are active by default.

Property Value      
Configuration ID config_30_1      
Data Type INTEGER      
Range 0 to 15   Default Value 0
Options All actions are active by default (0)      
  ignore turning ON with 1 click of the switch (1)      
  ignore turning OFF with 1 click of the switch (2)      
  ignore holding and releasing the switch (4)      
  ignore double click of the switch (8)      

31: S1 ON val sent to 2nd and 3rd groups

S1 switch - Switch ON value sent to 2nd and 3rd association groups

Property Value
Configuration ID config_31_2
Data Type INTEGER
Range 0 to 255
Default Value 255

32: S1 OFF val sent to 2nd and 3rd groups

S1 switch - Switch ON value sent to 2nd and 3rd association groups

Overview

This parameter defines value sent with Switch OFF command to devices associated in 2nd and 3rd association group.

Property Value
Configuration ID config_32_2
Data Type INTEGER
Range 0 to 255
Default Value 0

33: S1 DblClick val sent to 2nd and 3rd groups

S1 switch - Double Click value sent to 2nd and 3rd association groups

Overview

This parameter defines value sent with Double Click command to devices associated in 2nd and 3rd association group.

Property Value
Configuration ID config_33_2
Data Type INTEGER
Range 0 to 255
Default Value 99

35: S2 assocs. sent to 4th and 5th group

S2 switch - associations sent to 4th and 5th association groups

Overview

This parameter determines which actions result in sending commands to devices associated in 4th and 5th association group. All actions are active by default.

Property Value      
Configuration ID config_35_1      
Data Type INTEGER      
Range 0 to 15   Default Value 0
Options All actions are active by default (0)      
  ignore turning on with 1 click of the switch (1)      
  ignore turning off with 1 click of the switch (2)      
  ignore holding and releasing the switch (4)      
  ignore double click of the switch (8)      

36: S2 ON val sent to 4th and 5th groups

S2 switch - Switch ON value sent to 4th and 5th association groups

Property Value
Configuration ID config_36_2
Data Type INTEGER
Range 0 to 255
Default Value 255

36: S2 ON val sent to 4th and 5th groups

S2 switch - Switch ON value sent to 4th and 5th association groups

Property Value
Configuration ID config_36_2
Data Type INTEGER
Range 0 to 255
Default Value 255

37: S2 OFF val sent to 4th and 5th groups

S2 switch - Switch OFF value sent to 4th and 5th association groups

Property Value
Configuration ID config_37_2
Data Type INTEGER
Range 0 to 255
Default Value 0

38: S2 DblClick val sent to 4th and 5th groups

Property Value
Configuration ID config_38_2
Data Type INTEGER
Range 0 to 255
Default Value 99

40: Reaction to General Alarm

Reaction to General Alarm

Overview

This parameter determines how the device will react to General Alarm frame.

Property Value      
Configuration ID config_40_1      
Data Type INTEGER   Default Value 3
Options alarm frame is ignored (0)      
  turn ON after receiving the alarm frame (1)      
  turn OFF after receiving the alarm frame (2)      
  flash after receiving the alarm frame (3)      

41: Reaction to Flood Alarm

Reaction to Flood Alarm

Property Value      
Configuration ID config_41_1      
Data Type INTEGER   Default Value 2
Options alarm frame is ignored (0)      
  turn ON after receiving the alarm frame (1)      
  turn OFF after receiving the alarm frame (2)      
  flash after receiving the alarm frame (3)      

42: Reaction to CO/CO2/Smoke Alarm

Reaction to CO/CO2/Smoke Alarm

Property Value      
Configuration ID config_42_1      
Data Type INTEGER   Default Value 3
Options alarm frame is ignored (0)      
  turn ON after receiving the alarm frame (1)      
  turn OFF after receiving the alarm frame (2)      
  flash after receiving the alarm frame (3)      

43: Reaction to Heat Alarm

Reaction to Heat Alarm

Property Value      
Configuration ID config_43_1      
Data Type INTEGER   Default Value 1
Options alarm frame is ignored (0)      
  turn ON after receiving the alarm frame (1)      
  turn OFF after receiving the alarm frame (2)      
  flash after receiving the alarm frame (3)      

44: Flashing alarm duration

Flashing alarm duration

Overview

This parameter allows to set duration of flashing alarm mode.

Available settings: 1-32000 (1-32000s, 1s step) - duration

Default setting: 600 (10min)

Property Value
Configuration ID config_44_2
Data Type INTEGER
Range 1 to 32000
Default Value 600

50: First channel - power reports

First channel - power reports

Overview

This parameter determines the minimum change in consumed power that will result in sending new power report to the main controller.

Available settings:

  • 0 - reports are disabled
  • 1-100 (1-100%) - change in power
Property Value
Configuration ID config_50_1
Data Type INTEGER
Range 0 to 100
Default Value 20

51: 1st ch min time between reports

First channel - minimal time between power reports

Overview

This parameter determines minimum time that has to elapse before sending new power report to the main controller.

Available settings: 

0 - reports are disabled

1-120 (1-120s) - report interval

Default setting: 10 (10s)

Property Value
Configuration ID config_51_1
Data Type INTEGER
Range 0 to 120
Default Value 10

53: 1st ch energy reports

First channel - energy reports

Overview

This parameter determines minimum time that has to elapse before

sending new power report to the main controller.

Available settings:

0 - reports are disabled

1-32000 (0.01 - 320 kWh) - change in energy

Default: 100 (1 KWh)

Property Value
Configuration ID config_53_2
Data Type INTEGER
Range 0 to 32000
Default Value 100

54: Second channel - power reports

Second channel - power reports

Overview

This parameter determines the minimum change in consumed power that will result in sending new power report to the main controller.

Available settings:

  • 0 - reports are disabled
  • 1-100 (1-100%) - change in power
Property Value
Configuration ID config_54_1
Data Type INTEGER
Range 0 to 100
Default Value 20

55: 2nd ch min time between reports

Second channel - minimal time between power reports

Overview

This parameter determines minimum time that has to elapse before sending new power report to the main controller.

Available settings:

0 - periodic reports are disabled

1-120 (1-120s) - report interval

Default setting: 10 (10s)

Property Value
Configuration ID config_55_1
Data Type INTEGER
Range 0 to 120
Default Value 10

57: 2nd ch energy reports

Second channel - energy reports

Overview

This parameter determines the minimum change in consumed energy that will result in sending new energy report to the main controller.

Available settings:

0 - reports are disabled

1-32000 (0.01 - 320 kWh) - change in energy

Default setting: 100 (1 KWh)

Property Value
Configuration ID config_57_2
Data Type INTEGER
Range 0 to 32000
Default Value 100

58: Periodic power reports

Periodic power reports

Overview

This parameter determines in what time interval the periodic power reports are sent to the main controller.

Available settings: 

0 - periodic reports are disabled

1-32000 (1-32000s) - report interval

Default setting: 3600 (1h)

Property Value
Configuration ID config_58_2
Data Type INTEGER
Range 0 to 32000
Default Value 3600

59: Periodic energy reports

Periodic energy reports

Overview

This parameter determines in what time interval the periodic energy reports are sent to the main controller.

Available settings:

0 - periodic reports are disabled

1-32000 (1-32000s) - report interval

Default setting: 3600 (1h)

Property Value
Configuration ID config_59_2
Data Type INTEGER
Range 0 to 32000
Default Value 3600

60: Include own energy

Measuring energy consumed by the device itself

Overview

This parameter determines whether energy metering should include the amount of energy consumed by the device itself. Results are being added to energy reports for first endpoint.

Property Value      
Configuration ID config_60_1      
Data Type INTEGER   Default Value 0
Options function inactive (0)      
  function active (1)      

1: Lifeline

reports the device status and allows for assigning single device only (main controller by default).

Overview

1st association group – “Lifeline” reports the device status and allows for assigning single device only (main controller by default).

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: On/Off (S1)

On/Off (S1) is assigned to switch connected to the S1 terminal (uses Basic command class)

Overview

2nd association group – “On/Off (S1)” is assigned to switch connected to the S1 terminal (uses Basic command class).

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Dimmer (S1)

“Dimmer (S1)” is assigned to switch connected to the S1 terminal (uses Switch Multilevel command class)

Overview

“Dimmer (S1)” is assigned to switch connected to the S1 terminal (uses Switch Multilevel command class)

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: On/Off (S2)

On/Off (S2) is assigned to switch connected to the S2 terminal (uses Basic command class)

Overview

On/Off (S2) is assigned to switch connected to the S2 terminal (uses Basic command class)

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Dimmer (S2)

Dimmer (S2) is assigned to switch connected to the S2 terminal (uses Switch Multilevel command class)

Overview

Dimmer (S2) is assigned to switch connected to the S2 terminal (uses Switch Multilevel command class)

Property Value
Configuration ID group_5
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.