FGSD002 Smoke Detector

This describes the Z-Wave device FGSD002, manufactured by Fibargroup with the thing type UID of fibaro_fgsd002_00_000.

Smoke Detector

Channels

The following table summarises the channels available for the FGSD002 Smoke Detector.

Channel Channel Id Channel Type UID Category Item Type
Temperature Sensor sensor_temperature sensor_temperature Temperature Number
Smoke Alarm alarm_smoke alarm_smoke Door Switch
Tamper Alarm alarm_tamper alarm_tamper   Switch
Low Battery Alarm alarm_battery alarm_battery   Switch
Hardware Failure Alarm alarm_system alarm_system   Switch
Heat Alarm alarm_heat alarm_heat   Switch
  battery-level system.battery-level    
Clock Time Offset time_offset time_offset Temperature Number

Temperature Sensor

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Clock Time Offset

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the FGSD002 Smoke Detector. Detailed information on each parameter can be found below.

Parameter Description
1: Smoke Sensor sensitivity There are 3 levels of sensitivity to smoke presence.
2: Z-Wave notifications status This parameter allows to activate excess temperature …
2: Z-Wave notifications status This parameter allows to activate excess temperature …
3: Visual indicator notifications status This parameter allows to activate visual indications
4: Sound notifications status This parameter allows to activate sound signals…
10: Configuration of control frames in BASIC command class This parameter defines which frames will be sent …
11: BASIC ON frame value BASIC ON frame is sent in case of smoke presence detection …
12: BASIC OFF frame value BASIC OFF frame is sent in case of FIRE ALARM cancellation.
13: Alarm broadcast A value other than 0 means that alarms are being sent in …
20: Temperature report interval Time interval between consecutive temperature reports.
21: Temperature report hysteresis The temperature report will only be sent if there is a difference …
30: Temperature threshold Temperature threshold for activating alarms
31: Excess temperature signaling interval Time interval of signaling (visual indication/sound) excess …
32: Lack of Z-Wave range indication interval Time interval of signaling (visual indication/sound) lack of …
1: Device Status  
2: Battery capacity low  
3: Tamper Alarm  
4: Fire Alarm  
5: Tamper Alarm  

1: Smoke Sensor sensitivity

There are 3 levels of sensitivity to smoke presence.

Overview

Level 1 means the highest sensitivity. Rising the parameter value lowers the sensitivity to smoke presence.

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 2
Options HIGH Sensitivity (1)      
  MEDIUM Sensitivity (2)      
  LOW Sensitivity (3)      

2: Z-Wave notifications status

This parameter allows to activate excess temperature …

Overview

…  and/or enclosure opening notifications sent to the main controller

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 255
Options All notifications disabled (0)      
  Enclosure opening notification enabled (1)      
  Exceeding temperature threshold notification enabled (2)      
  All notifications enabled (3)      

2: Z-Wave notifications status

This parameter allows to activate excess temperature …

Overview

…  and/or enclosure opening notifications sent to the main controller

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 255
Default Value 255

3: Visual indicator notifications status

This parameter allows to activate visual indications

Overview

 but does not apply to major alarms, such as FIRE, TROUBLE and LOW BATTERY ALARM.

Available settings: 0 - 7

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options All notifications disabled (0)      
  Enclosure opening notification enabled (1)      
  Exceeding temperature threshold notification enabled (2)      
  Enclosure opening notification enabled + (3)      
  Lack of Z-Wave range notification (4)      
  Enclosure opening notification enabled + (5)      
  Exceeding temperature threshold notification enabled + (6)      
  Enclosure opening notification enabled + (7)      

4: Sound notifications status

This parameter allows to activate sound signals…

Overview

 but does not apply to major alarms, such as FIRE, TROUBLE and LOW BATTERY ALARM.

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options All notifications disabled (0)      
  Enclosure opening notification enabled (1)      
  Exceeding temperature threshold notification enabled (2)      
  Enclosure opening notification enabled + (3)      
  Lack of Z-Wave range notification (4)      
  Enclosure opening notification enabled + (5)      
  Exceeding temperature threshold notification enabled + (6)      
  Enclosure opening notification enabled + (7)      

10: Configuration of control frames in BASIC command class

This parameter defines which frames will be sent …

Overview

in the 2-nd Association Group (FIRE ALARM). The values of BASIC ON and BASIC OFF frames may be defined as described in further parameters.

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 0
Options BASIC ON and BASIC OFF enabled (0)      
  BASIC ON enabled (1)      
  BASIC OFF enabled (2)      

11: BASIC ON frame value

BASIC ON frame is sent in case of smoke presence detection …

Overview

and FIRE ALARM triggering. Its value is defined by the parameter. Available settings: 0-99, 255. 0 - turn off the device. 1-99 - set the device to 1-99%. 255 - set the last status

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 1 to 255
Default Value 255

12: BASIC OFF frame value

BASIC OFF frame is sent in case of FIRE ALARM cancellation.

Overview

Its value is defined by the parameter. Available settings: 0-99, 255. 0 - turn off the device. 1-99 - set the device to 1-99%. 255 - set the last status

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 255
Default Value 255

13: Alarm broadcast

A value other than 0 means that alarms are being sent in …

Overview

broadcast mode, i.e. to all devices within a Fibaro Smoke Sensor’s range

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 0
Options broadcast inactive (0)      
  FIRE ALARM broadcast (2-nd and 4-th Association Group) … (1)      
  FIRE ALARM broadcast (2-nd and 4-th Association Group) … (2)      
  FIRE ALARM broadcast (2-nd and 4-th Association Group) … (3)      

20: Temperature report interval

Time interval between consecutive temperature reports.

Overview

Report is sent when new temperature value is different from the one previously reported - according to the set hysteresis (parameter 21). Temperature reports can be also sent as a result of polling.

Available settings: 0, 1-8640 (multiply by 10 seconds) [10s-24h]

0 – reports inactive
1-8640 - [10s-24h]

Default setting: 1 (10 seconds)
Parameter size: 2 [bytes]

Property Value
Configuration ID config_20_2
Data Type INTEGER
Range 0 to 8640
Default Value 1

21: Temperature report hysteresis

The temperature report will only be sent if there is a difference …

Overview

in temperature value from the previous value reported, defined in this parameter (hysteresis). Temperature reports can be also sent as a result of polling.

Available settings: 1 – 100 (in 0,1oC steps)
1-100 - (multiply by 0,1) [0,1oC - 10oC]

Default setting: 10 (1oC)
Parameter size: 1 [byte]

Property Value
Configuration ID config_21_1
Data Type INTEGER
Range 1 to 100
Default Value 10

30: Temperature threshold

Temperature threshold for activating alarms

Overview

This is the temperature threshold, measured by the internal sensor above which the excess temperature notification is sent (visual indication/sound/Z-Wave report).

Note that the alarm will not be deactivated again until the temperature drops by at least 2 degrees below this threshold.

Property Value
Configuration ID config_30_1
Data Type INTEGER
Range 1 to 100
Default Value 55

31: Excess temperature signaling interval

Time interval of signaling (visual indication/sound) excess …

Overview

 temperature level

Available settings: 1-8640 (multiply by 10 seconds) [10s-24h]
1-8640 - [10s-24h]

Default setting: 1 (10 seconds)
Parameter size: 2 [bytes]

Property Value
Configuration ID config_31_2
Data Type INTEGER
Range 1 to 8640
Default Value 1

32: Lack of Z-Wave range indication interval

Time interval of signaling (visual indication/sound) lack of …

Overview

Z-Wave range.

Available settings: 1-8640 (multiply by 10 seconds) [10s-24h]
1-8640 - [10s-24h]

Default setting: 180 (30min)
Parameter size: 2 [bytes]

Property Value
Configuration ID config_32_2
Data Type INTEGER
Range 1 to 8640
Default Value 180

1: Device Status

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Battery capacity low

Overview

The Home Control Smoke Detector continuously checks the battery capacity. If the battery capacity falls below a defined value of approx. 2.7V +-0.1V, a low battery alarm will be sent via Z-Wave®. If the capacity continues falling, the visual and acoustic battery capacity warning will be activated additionally.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Tamper Alarm

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Fire Alarm

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Tamper Alarm

Property Value
Configuration ID group_5
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.