FGSS001 Smoke Sensor

This describes the Z-Wave device FGSS001, manufactured by Fibargroup with the thing type UID of fibaro_fgss001_00_000.

Smoke Sensor

Channels

The following table summarises the channels available for the FGSS001 Smoke Sensor.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
  battery-level system.battery-level    
Clock Time Offset time_offset time_offset Temperature Number
Alarm (smoke) alarm_smoke alarm_smoke Door Switch
Alarm (general) alarm_general alarm_general Door Switch
Alarm (heat) alarm_heat alarm_heat   Switch

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Clock Time Offset

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the FGSS001 Smoke Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Alarm Cancellation Delay Additional delay after an alarm has ceased. The parameter allows you to specify additional…
2: Acoustic and visual signals On / Off in case of alarm parameter allows for LED indicator and acoustic alarm deactivation in case of smoke detect…
5: Type of alarm frame sent to 1-st association group (SMOKE) parameter determines a type of command frame sent by the Sensor in case smoke detection ha…
7: Forced Level of Dimming group 1 Value of the parameter specifying the forced level of dimming / opening sun blinds when co…
10: Interval between successive readings of temperature sensors Interval between successive readings of temperature from all sensors connected to the devi…
12: Insensitiveness to temperature changes.  
13: Transmitting the alarm or control frame broadcast mode Transmitting the alarm or control frame in ‘broadcast’ mode (i.e. to all devices within ra…
73: Temperature measurement compensation Temperature value to be added to or deducted from the current measured temperature
80: Z-Wave range test interval Time period between the consecutive Z-Wave network range tests.
81: Temperature alarm threshold 0 -> 0 – temperature alarm inactive
82: Smoke Sensor sensitivity There are 3 levels of sensitivity to smoke presence. Level 1 means the highest sensitivity…
83: Black Box sensitivity level Parameter specifies temperature and smoke level after which the Black Box starts recording…
84: Malfunction alarm Time interval in which malfuntion alarm, if detected, is repeated using visual and acousti…
85: Temperature alarm Time interval in which temperature alarm, if detected, is repeated using visual and acoust…
86: Lack of the Z-Wave range alarm Time interval in which lack of the Z-Wave network alarm, if detected, is repeated using vi…
87: Low battery alarm Time interval in which low battery alarm, if detected, is repeated using visual and acoust…
88: Temperature measurement compensation for report Consider temperature measurement compensation (parameter 73) when sending temperature repo…
89: Tamper alarm Activates/inactivates temper switch alarm
1: Fire Status  
2: TMP Button  
3: Device Status  

1: Alarm Cancellation Delay

Additional delay after an alarm has ceased. The parameter allows you to specify additional time, after which the alarm is cancelled once its violation has ceased.

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 3600
Default Value 0

2: Acoustic and visual signals On / Off in case of alarm

parameter allows for LED indicator and acoustic alarm deactivation in case of smoke detection

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 3
Options acoustic and visual alarms inactive (0)      
  acoustic alarm inactive, visual alarm active (1)      
  acoustic alarm active, visual alarm inactive (2)      
  acoustic and visual alarms active (3)      

5: Type of alarm frame sent to 1-st association group (SMOKE)

parameter determines a type of command frame sent by the Sensor in case smoke detection has been detected or cancelled

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 255
Options ALARM SENSOR (SMOKE) (0)      
  BASIC_SET (255)      

7: Forced Level of Dimming group 1

Value of the parameter specifying the forced level of dimming / opening sun blinds when comes ‘switch on’ / ‘open’ command to devices from association group no. 1.
In the case of alarm frames the alarm priority is specified. Possible parameter setti

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 1 to 255
Default Value 255

10: Interval between successive readings of temperature sensors

Interval between successive readings of temperature from all sensors connected to the device in seconds. Note: taking temperature readings from the sensor does not result in sending a temperature condition report to the central hub.

Property Value
Configuration ID config_10_2
Data Type INTEGER
Range 1 to 32767
Default Value 300

12: Insensitiveness to temperature changes.

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 0 to 100
Default Value 20

13: Transmitting the alarm or control frame broadcast mode

Transmitting the alarm or control frame in ‘broadcast’ mode (i.e. to all devices within range), information sent in this mode is not repeated by the mesh network.
NOTE: If the broadcast mode of information transmission is activated for a given

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 0
Options Broadcast inactive (0)      
  Smoke broadcast mode active, Tamper broadcast mode inactive (1)      
  Smoke broadcast mode inactive, Tamper broadcast mode active (2)      
  Smoke and Tamper broadcast mode active (3)      

73: Temperature measurement compensation

Temperature value to be added to or deducted from the current measured temperature
-1000 0,1°C - 1000 0,1°C

Property Value
Configuration ID config_73_2
Data Type INTEGER
Range -1000 to 1000
Default Value 0

80: Z-Wave range test interval

Time period between the consecutive Z-Wave network range tests.
0 10min[10min-24h] - 17 10min[10min-24h] -> 0 – Z-Wave network range test inactive

Property Value
Configuration ID config_80_1
Data Type INTEGER
Range 0 to 255
Default Value 1

81: Temperature alarm threshold

0 -> 0 – temperature alarm inactive
2 °C - 100 °C -> Temperature

Property Value
Configuration ID config_81_1
Data Type INTEGER
Range 0 to 255
Default Value 54

82: Smoke Sensor sensitivity

There are 3 levels of sensitivity to smoke presence. Level 1 means the highest sensitivity.

Property Value      
Configuration ID config_82_1      
Data Type INTEGER   Default Value 2
Options High (1)      
  Medium (2)      
  Low (3)      

83: Black Box sensitivity level

Parameter specifies temperature and smoke level after which the Black Box starts recording them.

Property Value      
Configuration ID config_83_1      
Data Type INTEGER   Default Value 0
Options High (1)      
  Medium (2)      
  Low (3)      

84: Malfunction alarm

Time interval in which malfuntion alarm, if detected, is repeated using visual and acoustic alarms.
-126 100ms[100ms-25,5s] - 127 100ms[100ms-25,5s]

Property Value
Configuration ID config_84_1
Data Type INTEGER
Range -126 to 127
Default Value 10

85: Temperature alarm

Time interval in which temperature alarm, if detected, is repeated using visual and acoustic alarms.
-126 100ms[100ms-25,5s] - 127 100ms[100ms-25,5s] -> 5 means 500ms

Property Value
Configuration ID config_85_1
Data Type INTEGER
Range -126 to 127
Default Value 5

86: Lack of the Z-Wave range alarm

Time interval in which lack of the Z-Wave network alarm, if detected, is repeated using visual and acoustic alarms.
1 5s [5s-24h] - 17280 5s [5s-24h] -> 360 means 30min

Property Value
Configuration ID config_86_2
Data Type INTEGER
Range 1 to 17280
Default Value 360

87: Low battery alarm

Time interval in which low battery alarm, if detected, is repeated using visual and acoustic alarms.
1 5s [5s-24h] - 17280 5s [5s-24h] -> 360 means 30min

Property Value
Configuration ID config_87_2
Data Type INTEGER
Range 1 to 17280
Default Value 360

88: Temperature measurement compensation for report

Consider temperature measurement compensation (parameter 73) when sending temperature report.

Property Value      
Configuration ID config_88_1      
Data Type INTEGER   Default Value 0
Options Ignore temperature compensation (0)      
  Include temperature compensation (1)      

89: Tamper alarm

Activates/inactivates temper switch alarm

Property Value      
Configuration ID config_89_1      
Data Type INTEGER   Default Value 1
Options Tamper alarm inactive (0)      
  Tamper alarm active, with cancellation option available (1)      
  Tamper alarm active, without cancellation option (2)      

1: Fire Status

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: TMP Button

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Device Status

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.