FGT-001 Thermostatic Valve

This describes the Z-Wave device FGT-001, manufactured by Fibargroup with the thing type UID of fibaro_fgt001_00_000.

Thermostatic Valve

Overview

FIBARO Heat Controller is a remotely controlled thermostatic head to control temperature in the room. It measures the temperature and automatically adjust the heat level. It can be mounted without tools on three types of thermostatic radiator valves. It is also possible to create schedules via app to easily manage temperature throughout the week.
Main features:
• to be installed on three types of valves: M30 x 1.5, Danfoss RTD-N and Danfoss RA-N,
• compatible with any Z-Wave or Z-Wave+ Controller,
• supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 with PRNG-based encryption,
• built-in battery recharged through standard micro-USB port,
• easy installation - no tools required,
• can use dedicated temperature sensor,
• supports heating schedules,
• automatic calibration,
• anti-freeze function,
• decalc function,
• unconstrained rotation spherical knob to set desired temperature.

Inclusion Information

Add the device to the Z-Wave network:

  1. Make sure the device is within the direct range of your Z-Wave controller.

  2. Set the main controller in (security/non-security) add mode.

  3. Use the included key to quickly triple click the button on the thermostatic head.

  4. The LED ring will start blinking white.

  5. If you are adding in S2 authenticated mode, type in the device pin code (underlined part of the public key on the label).

  6. Wait for the adding process to end.

  7. Successful adding will be confirmed by the Z-Wave controller.

Exclusion Information

To remove the device from the Z-Wave network:

  1. Make sure the device is within the direct range of your Z-Wave controller.

  2. Set the main controller into remove mode.

  3. Use the included key to quickly triple click the button on the thermostatic head.

  4. The LED ring will start blinking white.

  5. Wait for the removing process to end.

  6. Successful removing will be confirmed by the Z-Wave controller.

Wakeup Information

FIBARO Heat Controller is a FLiRS device. The FLiRS device alternates between sleep mode and a partially awake mode in which it is listening beam signal. When device receives this beam, it immediately fully wakes up and then communicates with the controller or other Z-Wave device.

Channels

The following table summarises the channels available for the FGT-001 Thermostatic Valve.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Thermostat mode thermostat_mode fibaro_fgt001_00_000_thermostat_mode Temperature Number
Setpoint (heating) thermostat_setpoint_heating thermostat_setpoint Temperature Number
Alarm (power) alarm_power alarm_power Door Switch
Alarm (system) alarm_system alarm_system   Switch
  battery-level system.battery-level    
Clock Time Offset time_offset time_offset Temperature Number
Thermostat mode 1 thermostat_mode1 fibaro_fgt001_00_000_thermostat_mode Temperature Number
Setpoint (heating) 1 thermostat_setpoint_heating1 thermostat_setpoint Temperature Number
Alarm (power) 1 alarm_power1 alarm_power Door Switch
Alarm (system) 1 alarm_system1 alarm_system   Switch
  battery-level1 system.battery-level    
Clock Time Offset 1 time_offset1 time_offset Temperature Number
Sensor (temperature) 2 sensor_temperature2 sensor_temperature Temperature Number
Alarm (power) 2 alarm_power2 alarm_power Door Switch
  battery-level2 system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (heating)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Clock Time Offset

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Setpoint (heating) 1

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Clock Time Offset 1

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Sensor (temperature) 2

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the FGT-001 Thermostatic Valve. Detailed information on each parameter can be found below.

Parameter Description
1: Override Schedule duration This parameter determines duration of Override Schedule after turning the knob while norma…
2: Additional functions This parameter allows to enable different additional functions of the device.
3: Additional functions status (READ-ONLY) This parameter allows to check statuses of different additional functions.
1: Lifeline Lifeline

1: Override Schedule duration

This parameter determines duration of Override Schedule after turning the knob while normal schedule is active (set by Schedule CC).

Overview

Units = minutes

Property Value
Configuration ID config_1_4
Data Type INTEGER
Range 10 to 10000
Default Value 240

2: Additional functions

This parameter allows to enable different additional functions of the device.

Overview

Parameter 2 values may be combined, e.g. 1+8=9 means that Open Window Detector and LED indications when controlling remotely are enabled.

1 (bit 0) - enable Open Window Detector

2 (bit 1) - enable fast Open Window Detector

4 (bit 2) - increase receiver sensitivity (shortens battery life)

8 (bit 3) - enabled LED indications when controlling remotely

16 (bit 4) - protect from setting Full ON and Full OFF mode by turning the knob manually

Property Value
Configuration ID config_2_4
Data Type INTEGER
Range 0 to 31
Default Value 1

3: Additional functions status (READ-ONLY)

This parameter allows to check statuses of different additional functions.

Overview

Parameter 3 values may be combined, e.g. 1+2=3 means optional sensor works properly and open window detection was triggered.

1 (bit 0) - optional temperature sensor connected and operational

2 (bit 1) - open window detected

Property Value
Configuration ID config_3_4
Data Type INTEGER
Range 0 to 3
Default Value 0

1: Lifeline

Lifeline

Overview

Z-Wave Plus Lifeline association group that reports the device status and allows for assigning single device only (main controller by default)

Property Value
Configuration ID group_1
Data Type TEXT
Range to