FGWP101 Metered Wall Plug Switch

This describes the Z-Wave device FGWP101, manufactured by Fibargroup with the thing type UID of fibaro_fgwp101_00_000.

Metered Wall Plug Switch

Channels

The following table summarises the channels available for the FGWP101 Metered Wall Plug Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Sensor (power) sensor_power sensor_power Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Reset the total power consumption meter_reset meter_reset Energy Switch
LED color when device is on config_decimal_param61 fibaro_fgwp101_00_000_config_decimal_param61   Number
LED color when device is off config_decimal_param62 fibaro_fgwp101_00_000_config_decimal_param62   Number
Start Alarm LED Illumination notification_send notification_send   Number

Device Configuration

The following table provides a summary of the configuration parameters available in the FGWP101 Metered Wall Plug Switch. Detailed information on each parameter can be found below.

Parameter Description
1: Always on function Once activated, Wall Plug will keep a connected device …
16: Remember device status after power failure Define how will the Plug react after the power supply is back on.
34: Reaction to alarms Define Z-Wave network alarms to which the Wall Plug will respond.
35: Response to alarms Parameter defines how the Wall Plug will respond to alarms …
39: Alarm duration Wall Plug’s alarm mode duration. If a device sending an …
40: Immediate power report Parameter defines by how much power load must change …
42: Standard power load report Parameter defines by how much power load must change ..
43: Power reporting frequency This parameter defines how frequently standard power …
45: Reporting Changes in energy consumed by controlled devices Reporting changes in energy consumed by controlled devices
47: Time Period between reports on power and energy consumption Time Period between reports on power and energy …
49: Metering energy consumed by the Wall Plug itself. This parameter determines whether energy metering …
50: DOWN value Lower power threshold, used in parameter 52.
51: UP value Upper power threshold, used in parameter 52.
52: Action in case defined power values exceeded Parameter defines the way 2nd association group devices …
60: Power load to make red ring flash violet Function is active only when parameter 61 is set to 0 or 1.
61: LED color when device is on  
62: LED color when device is off  
63: LED color when Z Wave alarm  
70: Overload safety switch This function allows for turning off the controlled device…
1: Group 1 (on/off controlled devices)  
2: Group 2 (measured load controlled devices)  
3: Controller Updates  

1: Always on function

Once activated, Wall Plug will keep a connected device …

Overview

… ON, will stop reacting to alarm frames and B-button push.
“Always on” function turns the Plug into a power and energy meter.
Also, connected device will not be turned off upon receiving an alarm
frame from another Z-Wave device (parameter 35 will be ignored).
In “Always on” mode, connected device may be turned off only after
user defined power has been exceeded (parameter 70). In such a
case, connected device can be turned on again by pushing the
B-button or sending a control frame. By default, overload protection
is inactive. Default setting: 1

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options Activated (0)      
  Inactive (1)      

16: Remember device status after power failure

Define how will the Plug react after the power supply is back on.

Overview

Default setting: 1

Available settings:

  • 0 - Wall Plug does not memorize its state after a power failure.
  • 1 - Connected device will be off after the power supply is reconnected.
Property Value      
Configuration ID config_16_1      
Data Type INTEGER   Default Value 1
Options Do not remember state (0)      
  Remember state before power failure (1)      

34: Reaction to alarms

Define Z-Wave network alarms to which the Wall Plug will respond.

Overview

Default setting: 63

Available settings: 0 - 63.

  • 1 - general alarm
  • 2 - smoke alarm4 - CO alarm
  • 8 - CO2 alarm
  • 16 - high temperature alarm
  • 32 - flood alarm
Property Value
Configuration ID config_34_1
Data Type INTEGER
Range 0 to 63
Default Value 63

35: Response to alarms

Parameter defines how the Wall Plug will respond to alarms …

Overview

… (device’s status change) Default setting: 0
Available settings:
0 - no reaction,
1 - turn on connected device. LED ring signals an alarm through
defined time period (parameter 39) or untill the alarm is
cancelled.
2 - turn off connected device. LED ring signals an alarm through
defined time period (parameter 39) or untill the alarm is
cancelled.
3 - cyclically change device state, each 1second. In alarm mode
Wall Plug does not report status change, power changes,
ignores alarm frames. After the defined time period has passed
(parameter 39) or after the alarm cancellation, connected
device is set to the previous state.

Property Value      
Configuration ID config_35_1      
Data Type INTEGER   Default Value 0
Options No reaction (0)      
  Turn ON (1)      
  Turn OFF (2)      
  Cycle ON/OFF (3)      

39: Alarm duration

Wall Plug’s alarm mode duration. If a device sending an …

Overview

… alarm frame through the Z-Wave network sets alarm duration as well, this parameter’s settings are ignored.
Default setting: 600 (seconds).
Available settings: 1 - 65536 (seconds)
 

Property Value
Configuration ID config_39_2
Data Type INTEGER
Range 1 to 65535
Default Value 600

40: Immediate power report

Parameter defines by how much power load must change …

Overview

…in percents, to be reported to the main controller, with the highest
priority in the Z-Wave network. By default, Fibaro Wall Plug
immediately sends power report if the power load changes by 80%.
Default setting: 80 (%)
Available settings: 1 - 100 (%).
Value of 100 (%) means the reports are turned off.

Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 1 to 100
Default Value 80

42: Standard power load report

Parameter defines by how much power load must change ..

Overview

… in percents, to be reported to the main controller. By default, Fibaro
Wall Plug sends power report if the power load changes by 15%.
By default such changes in power load may be reported up to 5 times
per 30 seconds. Wall Plug sends 5 reports during time period
specified in paramater 43.
Default setting: 15 (%)
Available settings: 1 - 100 (%)
Value of 100 (%) means the reports are turned off

Property Value
Configuration ID config_42_1
Data Type INTEGER
Range 1 to 100
Default Value 15

43: Power reporting frequency

This parameter defines how frequently standard power …

Overview

… (parameter 42) will be sent. By default Wall Plug sends up to 5
reports each 30 seconds, provided the power load changes by 15%.
Default seting: 30 (s)
Available settings: 1 - 254 (s)
Value of 255 - Reports will be sent only as a result of parameter 47
settings or in case of polling.

Property Value
Configuration ID config_43_1
Data Type INTEGER
Range 1 to 255
Default Value 30

45: Reporting Changes in energy consumed by controlled devices

Reporting changes in energy consumed by controlled devices

Overview

… New, reported energy value is calculated based on last reported
value. Default setting: 10 (0,1 kWh).
Available settings: 1 - 254 (0,01kWh - 2,54kWh).
Value of 255 - changes in consumed energy will not be reported.
Reports will be sent only in case of polling.

Property Value
Configuration ID config_45_1
Data Type INTEGER
Range 1 to 255
Default Value 1

47: Time Period between reports on power and energy consumption

Time Period between reports on power and energy …

Overview

… consumption.

Parameter defines time period between reports sent when changes
in power load have not been recorded. By default, if power load
changes have not been recorded, reports are sent every hour.
Default setting: 3 600 (s),
Available settings: 1 - 65534 (s)
Value of 65535 - no periodic reports. Reports will be sent only in
case of power load / energy consumption changes (parameters 40,
42, 43,45) or in case of polling.

Property Value
Configuration ID config_47_2
Data Type INTEGER
Range 1 to 65534
Default Value 3600

49: Metering energy consumed by the Wall Plug itself.

This parameter determines whether energy metering …

Overview

… should include the amount of energy consumed by the Wall Plug itself.
Results are being added to energy consumed by controlled device.
Default setting: 0
Available settings:
0 - function inactive,
1 - function activated.

Property Value      
Configuration ID config_49_1      
Data Type INTEGER   Default Value 0
Options Inactive (0)      
  Activated (1)      

50: DOWN value

Lower power threshold, used in parameter 52.

Overview

Default setting: 300 (30 W)
Available settings: 0 - 25 000 (0,0W - 2 500W)
DOWN value cannot be higher than a value specified in parameter
51.

Property Value
Configuration ID config_50_2
Data Type INTEGER
Range 0 to 65535
Default Value 300

51: UP value

Upper power threshold, used in parameter 52.

Overview

Default setting: 500 (50 W)
Available settings: 1 - 25 000 (0,1W - 2 500W)
UP value cannot be lower than a value specified in parameter 50.

Property Value
Configuration ID config_51_2
Data Type INTEGER
Range 0 to 65535
Default Value 500

52: Action in case defined power values exceeded

Parameter defines the way 2nd association group devices …

Overview

… are controlled, depending on the current power load.
Default setting: 6
Available settings:
0 - function inactive,
1 - turn the associated devices on, once the power drops below
DOWN value (parameter 50),
2 - turn the associated devices off, once the power drops below
DOWN value (parameter 50),
3 - turn the associated devices on, once the power rises above UP
value (parameter 51),
4 - turn the associated devices off, once the power rises above UP
value (parameter 51),
5 - 1 and 4 combined. Turn the associated devices on, once the
power drops below DOWN value (parameter 50). Turn the
associated devices off, once the power rises above UP value
(parameter 51).
6 - 2 and 3 combined. Turn the associated devices off, once the
power drops below DOWN value (parameter 50). Turn the
associated devices on, once the power rises above UP value
(parameter 51).

Property Value      
Configuration ID config_52_1      
Data Type INTEGER   Default Value 6
Options Function inactive (0)      
  Turn devices ON when power below DOWN (1)      
  Turn devices OFF when power below DOWN (2)      
  Turn devices ON when power above UP (3)      
  Turn devices OFF when power above UP (4)      
  Turn devices ON when power below DOWN and off … (5)      
  Turn devices OFF when power below DOWN … (6)      

60: Power load to make red ring flash violet

Function is active only when parameter 61 is set to 0 or 1.

Overview

Default setting: 25 000 (2 500W)
Available settings: 1 000 - 32 000 (100W - 3200W)

Property Value
Configuration ID config_60_2
Data Type INTEGER
Range 0 to 65535
Default Value 25000

61: LED color when device is on

Property Value      
Configuration ID config_61_1      
Data Type INTEGER   Default Value 1
Options LED will use predefined steps depending on power (0)      
  LED will use continuous color depending on power (1)      
  White illumination (2)      
  Red illumination (3)      
  Green illumination (4)      
  Blue illumination (5)      
  Yellow illumination (6)      
  Cyan illumination (7)      
  Magenta illumination (8)      
  NO illumination (9)      

62: LED color when device is off

Property Value      
Configuration ID config_62_1      
Data Type INTEGER   Default Value 8
Options LED ring is illuminated with a color corresponding to … (0)      
  White illumination (1)      
  Red illumination (2)      
  Green illumination (3)      
  Blue illumination (4)      
  Yellow illumination (5)      
  Cyan illumination (6)      
  Magenta illumination (7)      
  NO illumination (8)      

63: LED color when Z Wave alarm

Property Value      
Configuration ID config_63_1      
Data Type INTEGER   Default Value 1
Options No change in color (0)      
  LED flashes RED BLUE WHITE (1)      
  White illumination (2)      
  Red illumination (3)      
  Green illumination (4)      
  Blue illumination (5)      
  Yellow illumination (6)      
  Cyan illumination (7)      
  Magenta illumination (8)      
  NO illumination (9)      

70: Overload safety switch

This function allows for turning off the controlled device…

Overview

… in case of exceeding the defined power. Controlled device will be turned off
even if “always on” function is active (parameter 1).
Controlled device can be turned back on via B-button or sending a
control frame. By default this function is inactive.
Default setting: 65 535 (6 553,5W)
Available settings: 10 - 65 535 (1W - 6 553,5W).
Value higher than 32 000 (3 200W) turns the overload safety switch
off, i.e. this functionality is turned off by default.

Property Value
Configuration ID config_70_2
Data Type INTEGER
Range 0 to 65535
Default Value 65535

1: Group 1 (on/off controlled devices)

Overview

Is assigned to the device status – sending command frames to the associated devices whenever the Wall Plug is turned ON or OFF via B-button.

Fibaro Association Group Info

Allows to control 5 regular and 5 multichannel devices per an association group.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2 (measured load controlled devices)

Overview

Is assigned to the measured active power – sending command frames to the associated devices depending on the measured load (configured via advanced parameters 50, 51 and 52).

Fibaro Association Group Info

Allows to control 5 regular and 5 multichannel devices per an association group.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Controller Updates

Overview

Reports the device status and allows to assign single device only (the main controller by default).

Fibaro Association Group Info

3rd group is reserved solely for the controller and hence only 1 node can be assigned.

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.