FGWP102 Metered Wall Plug Switch

This describes the Z-Wave device FGWP102, manufactured by Fibargroup with the thing type UID of fibaro_fgwp102_02_001.

Metered Wall Plug Switch

Channels

The following table summarises the channels available for the FGWP102 Metered Wall Plug Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Sensor (power) sensor_power sensor_power Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Reset the total power consumption meter_reset meter_reset Energy Switch
Alarm alarm_general alarm_general Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the FGWP102 Metered Wall Plug Switch. Detailed information on each parameter can be found below.

Parameter Description
1: Always on function Once activated, Wall Plug will keep a connected device constantly ON, will stop reacting t…
16: Remember device status after power failure Define how will the Plug react after the power supply is back on.
34: Reaction to alarms Define Z-Wave network alarms to which the Wall Plug will respond.
35: Response to alarms Parameter defines how the Wall Plug will respond to alarms (device’s status change).
39: Alarm duration Wall Plug’s alarm mode duration. If a device sending an alarm frame through the Z-Wave net…
40: Immediate power report Parameter defines by how much power load must change, in percents, to be reported to the m…
42: Standard power load report Parameter defines by how much power load must change, in percents, to be reported to the m…
43: Power reporting frequency This parameter defines how frequently standard power reports (parameter 42) will be sent. …
45: Reporting Changes in energy consumed by controlled devices Defines the required change in power to generate an unsolicited power report.
47: Time Period between reports on power and energy consumption Parameter defines time period between reports sent when changes in power load have not bee…
49: Metering energy consumed by the Wall Plug itself. This parameter determines whether energy metering should include the amount of energy cons…
50: DOWN value Lower power threshold, used in parameter 52.
51: UP value Upper power threshold, used in parameter 52.
52: Action in case defined power values exceeded Parameter defines the way 2nd association group devices are controlled, depending on the c…
60: Power load to make red ring flash violet Function is active only when parameter 61 is set to 0 or 1.
61: LED color when device is on  
62: LED color when device is off  
63: LED color when Z Wave alarm  
70: Overload safety switch This function allows for turning off the controlled device in case of exceeding the define…
1: Group 1  
2: Group 2  
3: Controller Updates  

1: Always on function

Once activated, Wall Plug will keep a connected device constantly ON, will stop reacting to alarm frames and B-button push.
‘Always on’ function turns the Plug into a power and energy meter. Also, connected device will not be turned off upon receivi

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options Activated (0)      
  Inactive (1)      

16: Remember device status after power failure

Define how will the Plug react after the power supply is back on.
Default setting: 1
Available settings:
0 - Wall Plug does not memorize its state after a power failure. Connected device will be off after the power supply is reconnected.

Property Value      
Configuration ID config_16_1      
Data Type INTEGER   Default Value 1
Options Do not remember state (0)      
  Remember state before power failure (1)      

34: Reaction to alarms

Define Z-Wave network alarms to which the Wall Plug will respond.
Default setting: 63
Available settings: 0 - 63.
1 - general alarm
2 - smoke alarm
4 - CO alarm
8 - CO2 alarm
16 - high temperature alarm
32 -

Property Value
Configuration ID config_34_1
Data Type INTEGER
Range 0 to 63
Default Value 63

35: Response to alarms

Parameter defines how the Wall Plug will respond to alarms (device’s status change).
Available settings:
0 - no reaction
1 - turn on connected device. LED ring signals an alarm through defined time period (parameter 39) or untill the ala

Property Value      
Configuration ID config_35_1      
Data Type INTEGER   Default Value 0
Options No reaction (0)      
  Turn ON (1)      
  Turn OFF (2)      
  Cycle ON/OFF (3)      

39: Alarm duration

Wall Plug’s alarm mode duration. If a device sending an alarm frame through the Z-Wave network sets alarm duration as well, this parameter’s settings are ignored.Default setting: 600 (seconds).Available settings: 1 - 65535 (seconds)

Property Value
Configuration ID config_39_2
Data Type INTEGER
Range 1 to 65535
Default Value 600

40: Immediate power report

Parameter defines by how much power load must change, in percents, to be reported to the main controller, with the highest priority in the Z-Wave network. By default, Fibaro Wall Plug immediately sends power report if the power load changes by 80%.

Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 1 to 100
Default Value 80

42: Standard power load report

Parameter defines by how much power load must change, in percents, to be reported to the main controller. By default, Fibaro Wall Plug sends power report if the power load changes by 15%. By default such changes in power load may be reported up to 5 times

Property Value
Configuration ID config_42_1
Data Type INTEGER
Range 1 to 100
Default Value 15

43: Power reporting frequency

This parameter defines how frequently standard power reports (parameter 42) will be sent. By default Wall Plug sends up to 5 reports each 30 seconds, provided the power load changes by 15%.
Default seting: 30 (s)
Available settings: 1 - 254

Property Value
Configuration ID config_43_1
Data Type INTEGER
Range 1 to 255
Default Value 30

45: Reporting Changes in energy consumed by controlled devices

Defines the required change in power to generate an unsolicited power report.
New, reported energy value is calculated based on last reported value. Default setting: 10 (0,1 kWh).
Available settings: 1 - 254 (0,01kWh - 2,54kWh).
Value

Property Value
Configuration ID config_45_1
Data Type INTEGER
Range 1 to 255
Default Value 1

47: Time Period between reports on power and energy consumption

Parameter defines time period between reports sent when changes in power load have not been recorded. By default, if power load changes have not been recorded, reports are sent every hour. Default setting: 3 600 (s)Available settings: 1 - 65534 (s)

Property Value
Configuration ID config_47_2
Data Type INTEGER
Range 1 to 65534
Default Value 3600

49: Metering energy consumed by the Wall Plug itself.

This parameter determines whether energy metering should include the amount of energy consumed by the Wall Plug itself.
Results are being added to energy consumed by controlled device.
Default setting: INACTIVE

Property Value      
Configuration ID config_49_1      
Data Type INTEGER   Default Value 0
Options Inactive (0)      
  Activated (1)      

50: DOWN value

Lower power threshold, used in parameter 52.
Default setting: 300 (30 W)
Available settings: 0 - 25 000 (0,0W - 2 500W)
DOWN value cannot be higher than a value specified in parameter 51.

Property Value
Configuration ID config_50_2
Data Type INTEGER
Range 0 to 65535
Default Value 300

51: UP value

Upper power threshold, used in parameter 52.
Default setting: 500 (50 W)
Available settings: 0 - 25 000 (0,0W - 2 500W)
UP value cannot be lower than a value specified in parameter 510

Property Value
Configuration ID config_51_2
Data Type INTEGER
Range 0 to 65535
Default Value 500

52: Action in case defined power values exceeded

Parameter defines the way 2nd association group devices are controlled, depending on the current power load.
Values are defined in parameters 50 and 51.
Available settings:
0 - function inactive
1 - turn the associated devices on

Property Value      
Configuration ID config_52_1      
Data Type INTEGER   Default Value 6
Options Function inactive (0)      
  Turn devices ON when power below DOWN (1)      
  Turn devices OFF when power below DOWN (2)      
  Turn devices ON when power above UP (3)      
  Turn devices OFF when power above UP (4)      
  Turn devices ON when power below DOWN and off when power above UP (5)      
  Turn devices OFF when power below DOWN and off when power above UP (6)      

60: Power load to make red ring flash violet

Function is active only when parameter 61 is set to 0 or 1.
Default setting: 25 000 (2 500W)
Available settings: 1 000 - 32 000 (100W - 3200W).

Property Value
Configuration ID config_60_2
Data Type INTEGER
Range 0 to 65535
Default Value 25000

61: LED color when device is on

Property Value      
Configuration ID config_61_1      
Data Type INTEGER   Default Value 1
Options LED will use predefined steps depending on power (0)      
  LED will use continuous color depending on power (1)      
  White illumination (2)      
  Red illumination (3)      
  Green illumination (4)      
  Blue illumination (5)      
  Yellow illumination (6)      
  Cyan illumination (7)      
  Magenta illumination (8)      
  NO illumination (9)      

62: LED color when device is off

Property Value      
Configuration ID config_62_1      
Data Type INTEGER   Default Value 8
Options LED will use predefined steps depending on the last power when on (0)      
  White illumination (1)      
  Red illumination (2)      
  Green illumination (3)      
  Blue illumination (4)      
  Yellow illumination (5)      
  Cyan illumination (6)      
  Magenta illumination (7)      
  NO illumination (8)      

63: LED color when Z Wave alarm

Property Value      
Configuration ID config_63_1      
Data Type INTEGER   Default Value 1
Options No change in color (0)      
  LED flashes RED BLUE WHITE (1)      
  White illumination (2)      
  Red illumination (3)      
  Green illumination (4)      
  Blue illumination (5)      
  Yellow illumination (6)      
  Cyan illumination (7)      
  Magenta illumination (8)      
  NO illumination (9)      

70: Overload safety switch

This function allows for turning off the controlled device in case of exceeding the defined power. Controlled device will be turned off even if ‘always on’ function is active (parameter 1).
Controlled device can be turned back on via B-button or sen

Property Value
Configuration ID config_70_2
Data Type INTEGER
Range 0 to 65535
Default Value 65535

1: Group 1

Overview

Is assigned to the device status – sending command frames to the associated devices whenever the Wall Plug is turned ON or OFF via B-button.

Fibaro Association Group Info

Allows to control 5 regular and 5 multichannel devices per an association group.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Overview

Is assigned to the measured active power – sending command frames to the associated devices depending on the measured load (configured via advanced parameters 50, 51 and 52).

Fibaro Association Group Info

Allows to control 5 regular and 5 multichannel devices per an association group.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Controller Updates

Overview

Reports the device status and allows to assign single device only (the main controller by default).

Fibaro Association Group Info

3rd group is reserved solely for the controller and hence only 1 node can be assigned.

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.