Forest Shuttle S/L, Forest Group NL Drapery hardware

This describes the Z-Wave device Forest Shuttle S/L, Forest Group NL, manufactured by Forest Group Nederland B.V with the thing type UID of forest_forestshuttlesl_00_000.

Drapery hardware

Overview

Role type: always on slave

Node type: z-wave plus node

Inclusion Information

Set your main controller into learn mode. Press configuration button 3 times. Led 3 is ON. Press and hold once more for 4 seconds, led will start blinking for 10 seconds. The Shuttle Z-wave motor will be detected and included into the Z-wave network of your controller.

Exclusion Information

To exclude, set your main controller into exclude mode. Press configuration button 3 times. Led 3 is ON. Press and hold once more for 4 seconds, led will start blinking for 10 seconds. The Shuttle Z-wave motor will be detected and excluded into the Z-wave network of your controller.

You can also reset the device, but only use this if your main controller is not operable. For reset, press the config button 25 times and confirm by pressing the button once more for 4 seconds until the led blinks 3 times and goes off.

Wakeup Information

Not specified

Channels

The following table summarises the channels available for the Forest Shuttle S/L, Forest Group NL Drapery hardware.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the Forest Shuttle S/L, Forest Group NL Drapery hardware. Detailed information on each parameter can be found below.

Parameter Description
1: lifeline  

1: lifeline

Overview

Node associated in this group will receive an unsolicited SWITCH_MULTILEVEL_REPORT frame every time the position of the curtain rail is changed, where the value represents the (changed) position.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.