WV-01 Wireless Z-Wave Water Valve

This describes the Z-Wave device WV-01, manufactured by FortrezZ LLC with the thing type UID of fortrezz_wv01_00_000.

The device is in the category of Valve, defining Valves used to control water or gas. e.g. a flow stop valve..

WV-01 product image

The WV-01 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the WV-01 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Alarm alarm_general Door Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the WV-01. Detailed information on each parameter can be found in the sections below.

Param Name Description
0 Mode  
1 WaterLevel Timeout  

Parameter 0: Mode

The following option values may be configured -:

Value Description
0 Alarm Mode
255 Level Mode

The manufacturer defined default value is 0 (Alarm Mode).

This parameter has the configuration ID config_0_1 and is of type INTEGER.

Parameter 1: WaterLevel Timeout

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 60.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_APPLICATION_STATUS_V1  
COMMAND_CLASS_SWITCH_BINARY_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_ALARM_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_VERSION_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.