MIMOlite Digital or Analog Voltage input and/or Dry Contact Relay

This describes the Z-Wave device MIMOlite, manufactured by FortrezZ LLC with the thing type UID of fortrezz_mimolite_00_000.

Digital or Analog Voltage input and/or Dry Contact Relay

Overview

The MIMOlite module provides one analog or digital input and one relay output (isolated dry contacts, NO-COM-NC) and can be controlled by ZWaveTM.  The system includes a program switch for Z-WaveTM inclusion/exclusion and a status light (LED) for various indications. 

Input SIG1 is an analog input, internally pulled-up to the MIMOlite supply voltage. The system allows trigger conditions to be set based on the input voltage being inside or outside a user-defined range (configured via Z-Wave).  This provides great flexibility for capturing events in a wide variety of applications. The trigger status of the input can be read via Z-WaveTM and/or can be automatically sent to a configured node, typically the Controller.  In addition, a count of the trigger events that have occurred for the input channel is internally recorded (and stored in the ‘pulse count’) and is available to be requested or automatically sent via Z-Wave.  The current triggered/un-triggered status can also be read via ZWave.  The SIG1 input can be associated with up to two other Z-WaveTM devices, such that an associated device will automatically turn on (or off) based on the occurrence of a trigger event.  Finally, the analog input channel can be configured so that the analog input level (not just binary trigger status) is periodically sent to up to two other associated nodes. 

The output relay is typically commanded via Z-WaveTM commands. In addition, the user can configure the input SIG1 trigger condition to be mapped to the output relay.  For example, Relay 1 can be automatically turned on based on Input SIG1 being triggered.  The relay activation can be set via a jumper or via Z-WaveTM for either momentary or latched operation.

Inclusion Information

  1. Set up the inclusion mode at the controller (for detailed directions, please refer to your controller user manual)
  2. If the LED has a periodic single blink, the unit will be automatically included.  Otherwise, the button has been previously pressed and automatic inclusion mode is no longer active.  In this case, briefly press the button once and the controller will indicate that the unit has been included in the network.  Also, the Status LED will blink when the inclusion completes. Inclusion and exclusion are always done at normal transmit power mode.  

Exclusion Information

  1. Set up the exclusion mode at the controller (for detailed directions, please refer to your controller user manual)
  2. Press the MIMOlite button and the controller will indicate the unit has been removed from the network. The Status LED will blink when the exclusion completes.  

Channels

The following table summarises the channels available for the MIMOlite Digital or Analog Voltage input and/or Dry Contact Relay.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (general) sensor_general sensor_general   Number
Alarm alarm_general alarm_general Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the MIMOlite Digital or Analog Voltage input and/or Dry Contact Relay. Detailed information on each parameter can be found below.

Parameter Description
2: Clear_Pulse_Meter_Counts  
3: Trigger_Mapping Input-to-relay Mapping
4: Lower_Threshold_High Lower Threshold, High
5: Lower_Threshold_Low Lower Threshold, Low
6: Upper_Threshold_High Upper Threshold, High
7: Upper_Threshold_Low Upper Threshold, Low
8: Trigger_Level_And_Input_Threshold  
9: Multilevel_AutoReport_Interval Multilevel AutoReport Interval
10: Not_Used_2  
11: Momentary_Relay1_Duration Momentary Relay1 output enable/disable (100msec).
1: Binary input Set Group  
2: MultiLevel Sensor report  
3: Power Alarm  
4: Binary Sensor report  
5: Pulse Meter Sensor report  

2: Clear_Pulse_Meter_Counts

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options Clear Pulse Meter Counts (0)      

3: Trigger_Mapping

Input-to-relay Mapping

Overview

The MIMOlite can be configured to automatically turn the relay on when the input is triggered or a Z-Wave command can also turn the relay on. The Configuration Command Class, Parameter 3, is used to set the input-to-relay mapping (See Technical Appendix). When input-to-relay mapping is enabled, Z-WaveTM commands to set the relay are overridden. The default for the relay is no input-to-relay mapping. Momentary vs Latched relay operation is selected by jumper P5 on the circuit board. The Momentary/Latched jumper is read only at power on when the MIMOlite is not in a ZWave network. When the jumper is off, momentary (default 500ms) operation is selected. If desired, once in-network, a Zwave configuration command (Parameter 11) can be used to override the jumper setting. The momentary configuration can be set from 100ms to 25.5ms (approximate) in increments of 100ms via the ZWave command. 

Note that neither a Basic Report nor a Binary Switch Report is sent when relay is automatically set or cleared by Trigger Mapping.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  SIG1 triggered/untriggered sets or clears Relay1 (1)      

4: Lower_Threshold_High

Lower Threshold, High

Overview

Lower Threshold, High (Default=0xBB; must be less than Upper Threshold Low and greater than Lower Threshold Low).

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 187
Options Default (0xBB) (187)      

5: Lower_Threshold_Low

Lower Threshold, Low

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 171
Options Default (0xAB) (171)      

6: Upper_Threshold_High

Upper Threshold, High

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 255
Options Default (0xFF) (255)      

7: Upper_Threshold_Low

Upper Threshold, Low

Overview

Upper Threshold, Low (Default = 0xFE; must be greater than Lower Threshold High and less than Upper Threshold High).

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 254
Options Default (0xFE) (254)      

8: Trigger_Level_And_Input_Threshold

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 3
Options ANALOG, trigger OUTSIDE of thresholds. (0)      
  ANALOG, trigger BETWEEN thresholds. (1)      
  DIGITAL, trigger OUTSIDE of thresholds. (2)      
  DIGITAL, trigger BETWEEN thresholds. (3)      

9: Multilevel_AutoReport_Interval

Multilevel AutoReport Interval

Overview

Periodic send interval of Multilevel Sensor Reports (Association Group 2) and/or Pulse Count Reports (Association Group 5) for SIG1. This parameter has a resolution of 10 seconds; for example, 1 = 10 seconds, 2 = 20 seconds, 3 = 30 seconds (Default), …, 255 = 2550 seconds = 42.5 minutes. A value of 0 disables automatic reporting.

Property Value      
Configuration ID config_9_1      
Data Type INTEGER   Default Value 3
Options Disable Automatic Reports (0)      
  Enable Reports every 30 seconds (Default) (3)      

10: Not_Used_2

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 0
Options Null (0)      

11: Momentary_Relay1_Duration

Momentary Relay1 output enable/disable (100msec).

Overview

Momentary Relay1 output enable/disable. 0 = disable (Default) 1..255 = enable / value sets the approximate momentary on time in increments of 100msec.

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 0
Options Disabled (Default) (0)      
  500 milliseconds (5)      

1: Binary input Set Group

Overview

When the input is triggered or untriggered, the MIMOlite will automatically send a Basic Set command to turn on or off the device(s) associated with this group.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: MultiLevel Sensor report

Overview

The MIMOlite will periodically send a MultiLevel Sensor report indicating the input’s analog voltage level.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Power Alarm

Overview

If a power dropout occurs, the MIMOlite will send an Alarm Command Class report (if there is enough available residual power).

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Binary Sensor report

Overview

When the input is triggered or untriggered, the MIMOlite will automatically send a Binary Sensor report to this group’s associated device(s).

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Pulse Meter Sensor report

Overview

Pulse meter counts will be sent to this group’s associated device(s). This will be sent periodically at the same intervals as Association Group 2, MLS Report except that if the pulse meter count is unchanged the report will not be sent.

Property Value
Configuration ID group_5
Data Type TEXT
Range to