26933/ZW3008 In-Wall Smart Motion Dimmer

This describes the Z-Wave device 26933/ZW3008, manufactured by Jasco Products with the thing type UID of ge_26933_00_000.

The 26933/ZW3008 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the 26933/ZW3008 -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number   Number
Alarm (burglar) alarm_burglar Door Switch
Switch 1 switch_dimmer1 DimmableLight Dimmer
Alarm (burglar) 2 alarm_burglar2 Door Switch

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Switch 1

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer1 channel supports the Dimmer item and is in the DimmableLight category.

Alarm (burglar) 2

Indicates if the burglar alarm is triggered.

The alarm_burglar2 channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Device Configuration

The following table provides a summary of the 19 configuration parameters available in the 26933/ZW3008. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Timeout Duration Amount of time the light stays on after motion stops
2 Dim Level Change brightness of associated light bulb(s)
3 Operation Mode Sets Manual, Vacancy (manual on, auto off), Occupancy (auto on, auto off)
4 Association Mode Enable/Disable Association Mode
5 Invert Switch In a 3-way configuration, invert the connected Add-On Switch buttons
6 Motion Sensor Enable/Disable Motion Sensor
7 Z-Wave Command Dim Step Indicates how many levels the dimmer will change for each dimming step.
8 Z-Wave Command Dim Rate How often the dim level will change in 10 millisecond resolution.
9 Local Control Dim Step Indicates how many levels the dimmer will change for each dimming step.
10 Local Control Dim Rate How often the dim level will change in 10 millisecond resolution.
11 ALL ON/ALL OFF Dim Step Indicates how many levels the dimmer will change for each dimming step.
12 ALL ON/ALL OFF Dim Rate How often the dim level will change in 10 millisecond resolution.
13 Motion Sensor Sensitivity Amount of motion required to turn on the light
14 Light Sensing Enable/Disable whether motion sensor only turns light on if room is dark
15 Reset Cycle Reset Cycle
16 Switch Mode  
17 Switch Level Switch Level
18 Dim Up Rate  
19 Exclusion mode  
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Timeout Duration

Amount of time the light stays on after motion stops

The following option values may be configured -:

Value Description
0 Test (5s)
1 1 minute
5 5 minutes
15 15 minutes
30 30 minutes
255 Disable timeout

The manufacturer defined default value is 5 (5 minutes).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Dim Level

Change brightness of associated light bulb(s) Valid values are 0-99 or 255 for last dimming level Values in the range 0 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Operation Mode

Sets Manual, Vacancy (manual on, auto off), Occupancy (auto on, auto off)

The following option values may be configured -:

Value Description
1 Manual
2 Vacancy
3 Occupancy

The manufacturer defined default value is 3 (Occupancy).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Association Mode

Enable/Disable Association Mode

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (Enabled).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Invert Switch

In a 3-way configuration, invert the connected Add-On Switch buttons

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Motion Sensor

Enable/Disable Motion Sensor

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (Enabled).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Z-Wave Command Dim Step

Indicates how many levels the dimmer will change for each dimming step. 1=Default
2-99=Steps/Levels Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Z-Wave Command Dim Rate

How often the dim level will change in 10 millisecond resolution. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. The default is 3 (30 ms). Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: Local Control Dim Step

Indicates how many levels the dimmer will change for each dimming step. 1=Default
2-99=Steps/Levels Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Local Control Dim Rate

How often the dim level will change in 10 millisecond resolution. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. The default is 3 (30 ms). Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: ALL ON/ALL OFF Dim Step

Indicates how many levels the dimmer will change for each dimming step. 1=Default
2=99=Steps/Levels Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: ALL ON/ALL OFF Dim Rate

How often the dim level will change in 10 millisecond resolution. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. The default is 3 (30 ms). Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 13: Motion Sensor Sensitivity

Amount of motion required to turn on the light

The following option values may be configured -:

Value Description
1 High
2 Medium
3 Low

The manufacturer defined default value is 2 (Medium).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Light Sensing

Enable/Disable whether motion sensor only turns light on if room is dark Light Sensing does not apply in Manual or Vacancy modes The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Reset Cycle

Reset Cycle 0=disable
1=10 seconds
2=20 seconds
3=30 seconds
4=45 seconds
5 to 109 = 15 second intervals, starting at 60 seconds
110=27 minutes 15 seconds Values in the range 0 to 110 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_15_2 and is of type INTEGER.

Parameter 16: Switch Mode

This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 17: Switch Level

Switch Level 0=disabled (default)
1-99=Brightness LevelThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 99 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Parameter 18: Dim Up Rate

The following option values may be configured -:

Value Description
0 Dim up the light to the default level quickly (Default)
1 Dim up the light to the default level slowly

The manufacturer defined default value is 0 (Dim up the light to the default level quickly (Default)).

This parameter has the configuration ID config_18_1 and is of type INTEGER.

Parameter 19: Exclusion mode

This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 Press and release any button on the switch (Default)
1 Press and release “X” btn and repeat for “ON“ btn

The manufacturer defined default value is 0 (Press and release any button on the switch (Default)).

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 26933/ZW3008 supports 3 association groups.

Group 1: Z-Wave Plus Lifeline

Z-Wave Plus Lifeline, Multi-Level Report This group supports 5 nodes.

Group 2: Basic Set Local Load

Supports Basic Set and is controlled with the local load This group supports 5 nodes.

Group 3: Basic Set Buttons

Supports Basic Set and is controlled by pressing the On or Off buttons This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V2| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_CRC_16_ENCAP_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V4| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V2| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| |

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_ALARM_V4 Linked to BASIC

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.